    An Adaptive Neuro-Fuzzy Inference System in Assessment of Technical Losses in Distribution Networks

    Get PDF
    The losses in distribution networks have always been key elements in predicting investment, planning work, evaluating the efficiency and effectiveness of a network. This paper elaborates on the use of fuzzy logic systems in analyzing the data from a particular substation area predicting losses in the low voltage network. The data collected from the field were obtained from the Automatic Meter Reading (AMR) and Automatic Meter Management (AMM) systems. The AMR system is fully implemented in EPHZHB and integrated within the network infrastructure at secondary level substations 35/10kV and 10(20)/0.4 kV. The AMM system is partially implemented in the areas of electrical energy consumers; precisely, in accounting meters. Daily information gathered from these systems is of great value for the calculation of technical and non-technical losses. Fuzzy logic in combination with the Artificial Neural Networks implemented via the Adaptive Neuro-Fuzzy Inference System (ANFIS) is used. Finally, FIS Sugeno, FIS Mamdani and ANFIS are compared with the measured data from smart meters and presented with their errors and graphs

    Frequency and Time Response of Power Plant Grounding System Exposed to Lightning Strike

    Get PDF
    This paper examines the frequency response of power plant grounding system exposed to the lightning current. Large amount of current generated by the stroke flow in the grounding system of power plant and dissipate in the soil.  The electric and magnetic field generated by such high voltages and currents may cause damage of equipment and may be dangerous for the personnel in power plant.  For the every given frequency obtained using Fast Fourier Transformation (FFT) of lightning current impulse, electromagnetic field theory approach is used to solve Maxell’s equation and compute scalar potential, electric and magnetic field. Also, the influence of the point in which lightning current is diffused in the grounding system is presented. Three dimensional plots of spatial distribution of scalar potential, electric and magnetic field are presented. The time domain response of scalar potential, electric and magnetic field on one profile is also presented

    Protection Coordination and Anti Islanding Protection Solution for Biomass Power Plant Connected on Distribution Network

    Get PDF
    Protection coordination as well as anti-island protection play significant role in the process of biomass power plant connection on the distribution network. Distribution generation island operation in Croatia is unacceptable according to the existing National grid code Paper presents a protection coordination of all passive protections used in the real biomass power plant and connected distriubution network feeder. Short-circuits three phase, two phase and single line to ground faults and generator islanding simulations have been performed and simulated in the time domain at the different network  locations using DIgSILENT Power Factory software. The time-current plots coordination of protective devices are made using Smart PDC module in Easy Power Protector software tool

    Transient Phenomena during the Three-Phase 300MVA Transformer Energization on the Transmission Network

    Get PDF
    Connecting the transformer to the network may incur inrush current, which is significantly higher than the rated current of the transformer. The main cause of this phenomenon lies in the nonlinearity of the magnetic circuit. The value of the inrush current depends of the time moment of the energization and the residual magnetism in the transformer core. While connecting, the operating point of the magnetization characteristic can be found deep in the saturation region resulting in occurrence of large transformer currents that can trigger the transformer protection. Tripping of protection immediately after the transformer energization raises doubts about the transformer health. Inrush current can cause a number of other disadvantages such as the negative impact on other transformers connected on the same busbar; the increase of the transformer noise due to the large current value, the increase of the voltage drops in the network. The paper presents a simulation of the 300 MVA transformer energization using the MATLAB/Simulink software. 

    Integration of Solar Power Plant in Distribution Network

    Get PDF
    This paper presents the integration of the solar power plant SE Gumiimpex, rated power of  1 MW in Croatian distribution network. Basic data of solar power plant are presented as well as the analysis of its impact on the distribution network. Power quality measurements, seven days before and seven days after the connection of PV plant to the grid are performed and obtained power quality indices are compared to those stated in the power quality standard HRN EN 50160/2012 and Croatian grid code. There are also presented results of the simulation of protection relays selection and coordinatio