1 research outputs found
Association of Hospital Volume with Perioperative Mortality of Endovascular Repair of Complex Aortic Aneurysms: A Nationwide Cohort Study
Objective: We evaluate nationwide perioperative outcomes of complex EVAR and assess the volume-outcome association of complex EVAR. Summary of Background Data: Endovascular treatment with fenestrated (FEVAR) or branched (BEVAR) endografts is progressively used for excluding complex aortic aneurysms (complex AAs). It is unclear if a volumeoutcome association exists in endovascular treatment of complex AAs (complex EVAR). Methods: All patients prospectively registered in the Dutch Surgical Aneurysm Audit who underwent complex EVAR (FEVAR or BEVAR) between January 2016 and January 2020 were included. The effect of annual hospital volume on perioperative mortality was examined using multivariable logistic regression analyses. Patients were stratified into quartiles based on annual hospital volume to determine hospital volume categories. Results: We included 694 patients (539 FEVAR patients, 155 BEVAR patients). Perioperative mortality following FEVAR was 4.5% and 5.2% following BEVAR. Postoperative complication rates were 30.1% and 48.7%, respectively. The first quartile hospitals performed <9 procedures/ yr; second, third, and fourth quartile hospitals performed 9-12, 13-22, and 23 procedures/yr. The highest volume hospitals treated significantly more complex patients. Perioperative mortality of complex EVAR was 9.1% in hospitals with a volume of <9, and 2.5% in hospitals with a volume of 13 (P = 0.008). After adjustment for confounders, an annual volume of 13 was associated with less perioperative mortality compared to hospitals with a volume of <9. Conclusions: Data from this nationwide mandatory quality registry shows a significant effect of hospital volume on perioperative mortality following complex EVAR, with high volume complex EVAR centers demonstrating lower mortality rates