167 research outputs found

    Developing the TeamOBS-vacuum-assisted delivery checklist to assess clinical performance in a vacuum-assisted delivery: a Delphi study with initial validation

    Get PDF
    IntroductionIn Northern Europe, vacuum-assisted delivery (VAD) accounts for 6–15% of all deliveries; VAD is considered safe when conducted by adequately trained personnel. However, failed vacuum extraction can be harmful to both the mother and child. Therefore, the clinical performance in VAD must be assessed to guide learning, determine a performance benchmark, and evaluate the quality to achieve an overall high performance. We were unable to identify a pre-existing tool for evaluating the clinical performance in real-life vacuum-assisted births.ObjectiveWe aimed to develop and validate a checklist for assessing the clinical performance in VAD.MethodsWe conducted a Delphi process, described as an interactive process where experts answer questions until answers converge toward a “joint opinion” (consensus). We invited international experts as Delphi panelists and reached a consensus after four Delphi rounds, described as follows: (1) the panelists were asked to add, remove, or suggest corrections to the preliminary list of items essential for evaluating clinical performance in VAD; (2) the panelists applied weights of clinical importance on a Likert scale of 1–5 for each item; (3) each panelist revised their original scores after reviewing a summary of the other panelists’ scores and arguments; and (4) the TeamOBS-VAD was tested using videos of real-life VADs, and the Delphi panel made final adjustments and approved the checklist.ResultsTwelve Delphi panelists from the UK (n = 3), Norway (n = 2), Sweden (n = 3), Denmark (n = 3), and Iceland (n = 1) were included. After four Delphi rounds, the Delphi panel reached a consensus on the checklist items and scores. The TeamOBS-VAD checklist was tested using 60 videos of real-life vacuum extractions. The inter-rater agreement had an intraclass correlation coefficient (ICC) of 0.73; 95% confidence interval (95% CI) of [0.58, 0.83], and that for the average of two raters was ICC 0.84 95% CI [0.73, 0.91]. The TeamOBS-VAD score was not associated with difficulties in delivery, such as the number of contractions during vacuum extraction delivery, cephalic level, rotation, and position. Failed vacuum extraction occurred in 6% of the video deliveries, but none were associated with the teams with low clinical performance scores.ConclusionThe TeamOBS-VAD checklist provides a valid and reliable evaluation of the clinical performance of vaginal-assisted vacuum extraction

    Towards better reliability in fetal heart rate variability using time domain and spectral domain analyses. A new method for assessing fetal neurological state?

    Get PDF
    OBJECTIVES: Fetal heart rate variability (FHRV) has shown potential in fetal surveillance. Therefore, we aimed to evaluate the reliability of time domain and spectral domain parameters based on non-invasive fetal electrocardiography (NI-FECG). METHOD: NI-FECG, with a sampling frequency of 1 kHz, was obtained in 75 healthy, singleton pregnant women between gestational age (GA) 20(+0) to 41(+0). The recording was divided into a) heart rate pattern (HRP) and b) periods fulfilling certain criteria of stationarity of RR-intervals, termed stationary heart rate pattern (SHRP). Within each recording, the first and the last time series from each HRP with less than 5% artifact correction were analyzed and compared. Standard deviation of normal-to-normal RR-intervals (SDNN), root mean square of successive differences (RMSSD), high frequency power (HF-power), low frequency power (LF-power), and LF-power/HF-power were performed. A multivariate mixed model was used and acceptable reliability was defined as intraclass correlation coefficient (ICC) ≥ 0.80 and a coefficient of variation (CV) ≤ 15%. Based on these results, the CV and ICC were computed if the average of two to six time series was used. RESULTS: For GA 28(+0) to 34(+6), SDNN and RMSSD exhibited acceptable reliability (CV 90%), whereas GA 35(+0) to 41(+0)and 20(+0) to 27(+6) showed higher CVs. Spectral domain parameters also showed high CVs However, by using the mean value of two to six time series, acceptable reliability in SDNN, RMSSD and HF-power from GA 28(+0) was achieved. Stationarity of RR-intervals showed high influence on reliability and SHRP was superior to HRP, whereas the length of the time series showed minor influence. CONCLUSION: Acceptable reliability seems achievable in SDNN, RMSSD and HF-power from gestational week 28. However, stationarity of RR-intervals should be considered when selecting time series for analyses

    Matrix metalloproteinases in the cervical mucus plug in relation to gestational age, plug compartment, and preterm labor

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>High concentrations of matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs) have been identified in the cervical mucus plug (CMP) at term of pregnancy. Their physiological and pathophysiological implications, however, remain to be elucidated, and CMPs from preterm labor have never been examined. This study was therefore conducted to describe the concentrations of MMP-2, TIMP-1, MMP-8 and MMP-9 in the CMP in relation to gestational age, IL-8 as an indicator of inflammation, compartment of the CMP, and preterm labor.</p> <p>Methods</p> <p>An aliquot of the distal plug compartment facing the vaginal microflora (CMP-dist) was collected from non-pregnant (n = 15), early pregnant (n = 15) and term pregnant women (n = 15). Whole CMPs shed during active vaginal term (n = 15) and preterm (n = 4) labor were also included. Protein concentrations were determined by enzyme-linked immunosorbent assay (ELISA).</p> <p>Results</p> <p>MMP-2 was not detectable in the non-pregnant CMP-dists whereas high concentrations were found in early pregnancy followed by an 85% decline at term. High concentrations of TIMP-1 were found in both the non-pregnant and early pregnant CMP-dists with a 90% decline at term. Consequently, the molar TIMP/MMP ratio was 40 in the non-pregnant state and 0.2 at term. The MMP-2 and TIMP-1 concentrations were alike in the CMP-dists and the whole CMPs.</p> <p>MMP-8, MMP-9, and IL-8 were mainly found in the distal CMP compartment. MMP-8 and MMP-9 concentrations were several fold increased in this compartment during pregnancy compared to the non-pregnant state. In the preterm whole CMPs, MMP-8, MMP-9 and IL-8 were 2 to 5 fold increased compared to term whole CMPs.</p> <p>Conclusions</p> <p>These results suggest that CMP MMP-2 reflects the non-leukocyte dependent cervical remodeling that occurs in early pregnancy, whereas MMP-8 and MMP-9 are involved in the defense against ascending infections primarily located to the distal compartment of the CMP. The upregulation of MMP-8, MMP-9 and IL-8 in whole CMPs from preterm labor may indicate the involvement of an intrauterine infection.</p

    Effects of antenatal hypnosis on maternal salivary cortisol during childbirth and six weeks postpartum-A randomized controlled trial

    Get PDF
    BACKGROUND:Cortisol has been used to capture psychophysiological stress during childbirth and postpartum wellbeing. We explored the effect of a brief antenatal training course in self-hypnosis on salivary cortisol during childbirth and 6 weeks postpartum. METHODS:In a randomized, controlled trial conducted at Aarhus University Hospital Skejby Denmark during the period January 2010 until October 2010, a total of 349 healthy nulliparous women were included. They were randomly allocated to a hypnosis group (n = 136) receiving three one-hour lessons in self-hypnosis with additional audio-recordings, a relaxation group (n = 134) receiving three one-hour lessons in various relaxation methods with audio-recordings for additional training, and a usual care group (n = 79) receiving ordinary antenatal care only. Salivary cortisol samples were collected during childbirth (at the beginning of the pushing state, 30 minutes, and 2 hours after childbirth), and 6 weeks postpartum (at wake up, 30 minutes after wake up, and evening). Cortisol concentrations were compared using a linear mixed-effects model. Correlations between cortisol concentrations and length of birth, experienced pain and calmness during birth were examined by a Spearman rank correlation test. FINDINGS:During childbirth, week correlations were found between cortisol concentrations 30 minutes after childbirth and length of birth. In the beginning of the pushing state and 2 hours after childbirth, we found a tendency towards higher cortisol concentrations in the hypnosis group compared to the other two groups (hypnosis versus relaxation p = 0.02 and 0.03, hypnosis versus usual care p = 0.08 and 0.05). No differences were observed in cortisol concentrations between the groups 30 minutes after childbirth (hypnosis versus relaxation p = 0.08, hypnosis versus usual care 0.10) or 6 weeks postpartum (hypnosis versus relaxation: p = 0.85, 0.51, and 0.68, hypnosis versus usual care: p = 0.85, 0.93, and 0.96). CONCLUSION:Antenatal hypnosis training may increase the release of cortisol during childbirth with no long-term consequences. Further research is needed to help interpret these findings

    Fetal respiratory movements improve reliability of heart rate variability and suggest a coupling between fetal respiratory arrhythmia and vagal activity

    Get PDF
    Fetal heart rate variability (FHRV) reflects autonomic cardiac regulation. The autonomic nervous system constantly adjusts the heart rate to maintain homeostasis. By providing insight into the fetal autonomic state, FHRV has the potential to become an investigational and clinical instrument. However, the method needs standardization and the influence of fetal movements, including fetal respiratory movements, is not well explored. Therefore, in a highly standardized setting, the aim was to evaluate the association between fetal movements and fetal heart rate variability (FHRV) including their impact on reliability. Fetal heart rate was obtained by noninvasive fetal electrocardiography (NI‐FECG) and fetal movements by simultaneous ultrasound scanning in 30 healthy singleton pregnant women on two occasions with a maximum interval of 7 days. The standard deviation of normal‐to‐normal RR‐intervals (SDNN), root mean square of successive RR‐interval differences (RMDDS), high‐frequency power (HF‐power), low‐frequency power (LF‐power), and LF/HF were measured. A multivariate mixed model was used and reliability was defined as acceptable by a coefficient of variance (CV) ≤15% and an intraclass correlation coefficient (ICC) ≥0.80. During time periods with fetal respiratory movements, the highest reliability was achieved. Intra‐ and inter‐observer reliability measurements were very high (CV: 0–9%; ICC ≧ 0.86). Within the same recording, SDNN and RMSSD achieved acceptable reliability (CV: 14–15%; ICC ≧ 0.80). However, day‐to‐day reliability displayed high CV’s. In time periods with fetal respiratory movements, as compared to periods with quiescence RMSSD and HF‐power were higher (Ratio: 1.33–2.03) and LF/HF power lower (Ratio: 0.54). In periods with fetal body movements SDNN, RMSSD and HF‐power were higher (Ratio: 1.27–1.65). In conclusion, time periods with fetal respiratory movements were associated with high reliability of FHRV analyses and the highest values of parameters supposed to represent vagal activity

    Growth-restricted human fetuses have preserved respiratory sinus arrhythmia but reduced heart rate variability estimates of vagal activity during quiescence

    Get PDF
    The aim was to assess the association between fetal growth restriction (FGR) and fetal heart rate variability (FHRV) in relation to fetal movements. A prospective observational cohort study was performed. Non‐invasive fetal electrocardiography (NI‐FECG) allowed beat‐to‐beat assessments with <5% corrections of RR intervals. FHRV analyses included: Root mean square of successive RR interval differences (RMSSD), high frequency power (HF power), and low frequency power (LF power). Fetal movements were categorized by continuous ultrasound scanning. We enrolled 36 singleton pregnant women expecting a small fetus (< the 2.3 percentile of mean weight for gestational age) diagnosed by ultrasound, of whom 25 presented with a birthweight < the 2.3 percentile. Among these, 11 were excluded due to low quality NI‐FECG recordings, leaving 14 women with 28 recordings eligible for inclusion in the analyses. The control group consisted of 22 healthy fetuses with birthweights between the 10th and the 90th percentile (average for gestational age [AGA]). In FGR fetuses the HRV response to respiratory activity was comparable to that of AGA fetuses. RMSSD (Ratio 1.54 [95% CI: 1.33; 1.79]) and HF power (Ratio 2.88 [95% CI: 2.12; 3.91]) increased, whereas LF/HF power (Ratio: 0.44 [95% CI: 0.31;0.63]) decreased. However, during fetal quiescence, FGR fetuses differed significantly from AGA fetuses. Compared to AGA fetuses, FGR fetuses displayed lower RMSSD (Ratio 0.77 (95% CI: 0.58; 1.02)) and HF power (Ratio 0.56 (95% CI:0.32; 0.98)). This reduction was associated with the severity of the FGR. In conclusion, FGR fetuses displayed a respiratory sinus arrhythmia (RSA) comparable to AGA fetuses; however, more important, parameters representing cardiac vagal activity were impaired in FGR fetuses during quiescence. RSA may constitute an intrinsic function of the cardiovascular system, which is unaffected by fetal compromise. However, the basic cardiac outflow assessed during fetal quiescence indicates a suppressed cardiac vagal activity in the FGR fetuses

    Cervical collagen and biomechanical strength in non-pregnant women with a history of cervical insufficiency

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It has been suggested that cervical insufficiency (CI) is characterized by a "muscular cervix" with low collagen and high smooth muscle concentrations also in the non-pregnant state. Therefore, the aim of this study was to investigate the biomechanical properties, collagen concentration, smooth muscle cell density, and collagen fiber orientation in cervical biopsies from non-pregnant women with a history of CI.</p> <p>Methods</p> <p>Cervical punch biopsies (2 × 15 mm) were obtained from 57 normal non-pregnant women and 22 women with a history of CI. Biomechanical tensile testing was performed, and collagen content was determined by hydroxyproline quantification. Histomorphometry was used to determine the volume densities of extracellular matrix and smooth muscle cells from the distal to the proximal part of each sample. Smooth muscle cells were identified using immunohistoche-mistry. Finally, collagen fiber orientation was investigated. Data are given as mean +/- SD.</p> <p>Results</p> <p>Collagen concentration was lower in the CI group (58.6 +/- 8.8%) compared with the control group (62.2 +/- 6.6%) (p = 0.033). However, when data were adjusted for age and parity, no difference in collagen concentration was found between the two groups. Maximum load of the specimens did not differ between the groups (p = 0.78). The tensile strength of cervical collagen, i.e. maximum load normalized per unit collagen (mg of collagen per mm of specimen length), was increased in the CI group compared with controls (p = 0.033). No differences in the volume density of extracellular matrix or smooth muscle cells were found between the two groups. Fibers not oriented in the plane of sectioning were increased in CI patients compared with controls.</p> <p>Conclusions</p> <p>Cervical insufficiency does not appear to be associated with a constitutionally low collagen concentration or collagen of inferior mechanical quality. Furthermore, the hypothesis that a "muscular cervix" with an abundance of smooth muscle cells contributes to the development of cervical insufficiency is not supported by the present study.</p
    • …
    corecore