8 research outputs found
Rheological and biological properties of a hydrogel support for cells intended for intervertebral disc repair
<p>Abstract</p> <p>Background</p> <p>Cell-based approaches towards restoration of prolapsed or degenerated intervertebral discs are hampered by a lack of measures for safe administration and placement of cell suspensions within a treated disc. In order to overcome these risks, a serum albumin-based hydrogel has been developed that polymerizes after injection and anchors the administered cell suspension within the tissue.</p> <p>Methods</p> <p>A hydrogel composed of chemically activated albumin crosslinked by polyethylene glycol spacers was produced. The visco-elastic gel properties were determined by rheological measurement. Human intervertebral disc cells were cultured <it>in vitro </it>and <it>in vivo </it>in the hydrogel and their phenotype was tested by reverse-transcriptase polymerase chain reaction. Matrix production and deposition was monitored by immuno-histology and by biochemical analysis of collagen and glycosaminoglycan deposition. Species specific <it>in situ </it>hybridization was performed to discriminate between cells of human and murine origin in xenotransplants.</p> <p>Results</p> <p>The reproducibility of the gel formation process could be demonstrated. The visco-elastic properties were not influenced by storage of gel components. <it>In vitro </it>and <it>in vivo </it>(subcutaneous implants in mice) evidence is presented for cellular differentiation and matrix deposition within the hydrogel for human intervertebral disc cells even for donor cells that have been expanded in primary monolayer culture, stored in liquid nitrogen and re-activated in secondary monolayer culture. Upon injection into the animals, gels formed spheres that lasted for the duration of the experiments (14 days). The expression of cartilage- and disc-specific mRNAs was maintained in hydrogels <it>in vitro </it>and <it>in vivo</it>, demonstrating the maintenance of a stable specific cellular phenotype, compared to monolayer cells. Significantly higher levels of hyaluronan synthase isozymes-2 and -3 mRNA suggest cell functionalities towards those needed for the support of the regeneration of the intervertebral disc. Moreover, mouse implanted hydrogels accumulated 5 times more glycosaminoglycans and 50 times more collagen than the <it>in vitro </it>cultured gels, the latter instead releasing equivalent quantities of glycosaminoglycans and collagen into the culture medium. Matrix deposition could be specified by immunohistology for collagen types I and II, and aggrecan and was found only in areas where predominantly cells of human origin were detected by species specific <it>in situ </it>hybridization.</p> <p>Conclusions</p> <p>The data demonstrate that the hydrogels form stable implants capable to contain a specifically functional cell population within a physiological environment.</p
Metallic oxide nanoparticles stimulate blood coagulation independent of their surface charge
Positively charged metallic oxides prevent blood coagulation whereas negatively charged metallic oxides are thrombogenic. This study was performed to examine whether this effect extends to metallic oxide nanoparticles. Oscillation shear rheometry was used to study the effect of zinc oxide and silicon dioxide nanoparticles on thrombus formation in human whole blood. Our data show that oscillation shear rheometry is a sensitive and robust technique to analyze thrombogenicity induced by nanoparticles. Blood without previous contact with nanoparticles had a clotting time (CT) of 16.7 ± 1.0 min reaching a maximal clot strength (CS) of 16 ± 14 Pa (G') after 30 min. ZnO nanoparticles (diameter 70 nm, +37 mV zeta-potential) at a concentration of 1 mg/mL prolonged CT to 20.8 ± 3.6 min and provoked a weak clot (CS 1.5 ± 1.0 Pa). However, at a lower concentration of 100 µg/mL the ZnO particles dramatically reduced CT to 6.0 ± 0.5 min and increased CS to 171 ± 63 Pa. This procoagulant effect decreased at lower concentrations reaching the detection limit at 10 ng/mL. SiO2 nanoparticles (diameter 232 nm, −28 mV zeta-potential) at high concentrations (1 mg/mL) reduced CT (2.1 ± 0.2 min) and stimulated CS (249 ± 59 Pa). Similar to ZnO particles, this procoagulant effect reached a detection limit at 10 ng/mL. Nanoparticles in high concentrations reproduce the surface charge effects on blood coagulation previously observed with large particles or solid metal oxides. However, nanoparticles with different surface charges equally well stimulate coagulation at lower concentrations. This stimulation may be an effect which is not directly related to the surface charge
