114 research outputs found

    A study of priority dispatching in an integraded circuit shop

    Get PDF
    This study considers the effects of ten priority dispatching rules on an actual integrated circuit shop environment

    Whose Job Is It Anyway? Preparing Arbitrators for Consumer Dispute Resolution Programs

    Get PDF
    [Excerpt] In many respects, we have entered into a golden era in the evolution and study of conflict resolution. One of the most obvious examples of this new era is the significant growth of conflict resolution programs in institutions of higher education. The purpose of this article is to examine the current state of university and law school conflict resolution programs. We then offer some conclusions and recommendations for addressing what we believe to be the critically important role academia can and should play in training arbitrators. Our review of academic programs suggests that the array of offerings has grown substantially and includes credit courses, clinics, degree programs, and certificates in conflict resolution. At our own institution, Cornell University, the response by our student body to opportunities for studying conflict resolution has overwhelmed our current capacity to meet their needs and interests

    Barriers to Participatory eRulemaking Platform Adoption: Lessons Learned from RegulationRoom

    Get PDF
    Rulemaking, the process through which United States (U.S.) federal government agencies develop major health, safety and economic regulations, was an early target of electronic government (e-government) efforts. Because it was an established decision-making process that had substantial formal requirements of transparency, public participation and responsiveness it seemed a perfect target for technology-supported participatory policymaking. It was believed that new technologies could transform rulemaking, increasing its democratic legitimacy and improving its policy outcomes by broadening the range of participating individuals and groups (Brandon and Carlitz, 2003; Coglianese, 2004; Noveck, 2004). Despite the promise of a more deliberative and democratic process, rulemaking efforts have failed to produce broader meaningful public engagement. In this paper we examine if lack of adoption of participatory eRulemaking platforms can be explained by the disruption to agencies’ established rulemaking practices. We will consider how agencies react to technological innovation as a risk due to their deep-rooted organizational cultures and the impact of judicial and political oversight. We will provide examples of agency risk and culture, including from our own experiences with RegulationRoom, a socio-technological participation platform that has facilitated public participation in six federal rulemakings. We will also draw on a comparison of for-profit businesses and rulemaking agencies in thinking about motivation to adopt (or avoid) new technologies

    HSV-1 Remodels Host Telomeres to Facilitate Viral Replication

    Get PDF
    SummaryTelomeres protect the ends of cellular chromosomes. We show here that infection with herpes simplex virus 1 (HSV-1) results in chromosomal structural aberrations at telomeres and the accumulation of telomere dysfunction-induced DNA damage foci (TIFs). At the molecular level, HSV-1 induces transcription of telomere repeat-containing RNA (TERRA), followed by the proteolytic degradation of the telomere protein TPP1 and loss of the telomere repeat DNA signal. The HSV-1-encoded E3 ubiquitin ligase ICP0 is required for TERRA transcription and facilitates TPP1 degradation. Small hairpin RNA (shRNA) depletion of TPP1 increases viral replication, indicating that TPP1 inhibits viral replication. Viral replication protein ICP8 forms foci that coincide with telomeric proteins, and ICP8-null virus failed to degrade telomere DNA signal. These findings suggest that HSV-1 reorganizes telomeres to form ICP8-associated prereplication foci and to promote viral genomic replication

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Full text link
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3σ\sigma (5σ\sigma) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3σ\sigma level with a 100 kt-MW-yr exposure for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest

    Long-baseline neutrino oscillation physics potential of the DUNE experiment

    Get PDF
    The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all ΑCP values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all ΑCP values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sin22Ξ13 to current reactor experiments

    First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

    Get PDF
    The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP\u27s performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP\u27s successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design

    Long-baseline neutrino oscillation physics potential of the DUNE experiment

    Get PDF
    The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σ, for all ÎŽ_(CP) values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all ÎŽ_(CP) values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to sinÂČξ₁₃ to current reactor experiments
    • 

    corecore