47 research outputs found

    Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE

    Get PDF
    AIM: To compare three-dimensional (3D) k-t sensitivity encoded (k-t SENSE) cine cardiovascular magnetic resonance (CMR), before and after contrast administration, against standard 2D imaging for the assessment of left ventricular volumes and mass. METHOD: Twenty-six subjects (14 volunteers, 12 patients) underwent multiple breathhold 2D balanced turbo-field echo cine CMR in addition to k-t SENSE accelerated 3D imaging (acceleration factor 5; 5x k-t SENSE), performed before and after administration of a high-relaxivity gadolinium-based contrast agent (Gadobutrolum). k-t acceleration factors of 7 and 10 were also assessed in six volunteers. Left ventricular end diastolic volume (EDV), end systolic volume (ESV), mass, and ejection fraction (EF) were calculated for each method. RESULTS: There was at least moderate agreement between the EDV, ESV, mass and EF calculated by 2D and 3D 5x k-t SENSE methods before contrast (concordance coefficients 0.92, 0.95, 0.97, 0.92, respectively). Agreement improved following contrast (concordance coefficients 0.97, 0.99, 0.98, 0.93, respectively). The 3D method underestimated all parameters compared to 2D (mean bias pre-contrast 6.1 ml, 0.6 ml, 3.5 g, 2.0% respectively). 3D image quality scores were significantly poorer than 2D, showing a non-significant trend to improvement following contrast administration. Parameters derived with k-t acceleration factors of 7 and 10 showed poorer agreement with 2D values. CONCLUSION: Left ventricular volumes and mass are reliably assessed using 3D 5x k-t SENSE accelerated CMR. Contrast administration further improves agreement between 5x k-t SENSE and 2D-derived measurements. k-t acceleration factors greater than 5, though feasible, produce poorer agreement with 2D values

    Clinical evaluation of magnetic resonance imaging in coronary heart disease: The CE-MARC study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Several investigations are currently available to establish the diagnosis of coronary heart disease (CHD). Of these, cardiovascular magnetic resonance (CMR) offers the greatest information from a single test, allowing the assessment of myocardial function, perfusion, viability and coronary artery anatomy. However, data from large scale studies that prospectively evaluate the diagnostic accuracy of multi-parametric CMR for the detection of CHD in unselected populations are lacking, and there are few data on the performance of CMR compared with current diagnostic tests, its prognostic value and cost-effectiveness.</p> <p>Methods/design</p> <p>This is a prospective diagnostic accuracy cohort study of 750 patients referred to a cardiologist with suspected CHD. Exercise tolerance testing (ETT) will be preformed if patients are physically able. Recruited patients will then undergo CMR and single photon emission tomography (SPECT) followed in all patients by invasive X-ray coronary angiography. The order of the CMR and SPECT tests will be randomised. The CMR study will comprise rest and adenosine stress perfusion, cine imaging, late gadolinium enhancement and whole-heart MR coronary angiography. SPECT will use a gated stress/rest protocol. The primary objective of the study is to determine the diagnostic accuracy of CMR in detecting significant coronary stenosis, as defined by X-ray coronary angiography. Secondary objectives include an assessment of the prognostic value of CMR imaging, a comparison of its diagnostic accuracy against SPECT and ETT, and an assessment of cost-effectiveness.</p> <p>Discussion</p> <p>The CE-MARC study is a prospective, diagnostic accuracy cohort study of 750 patients assessing the performance of a multi-parametric CMR study in detecting CHD using invasive X-ray coronary angiography as the reference standard and comparing it with ETT and SPECT.</p> <p>Trial Registration</p> <p>Current Controlled Trials ISRCTN77246133</p
    corecore