788 research outputs found
Preservation of tetherin and CD4 counter-activities in circulating Vpu alleles despite extensive sequence variation within HIV-1 infected individuals.
The HIV-1 Vpu protein is expressed from a bi-cistronic message late in the viral life cycle. It functions during viral assembly to maximise infectious virus release by targeting CD4 for proteosomal degradation and counteracting the antiviral protein tetherin (BST2/CD317). Single genome analysis of vpu repertoires throughout infection in 14 individuals infected with HIV-1 clade B revealed extensive amino acid diversity of the Vpu protein. For the most part, this variation in Vpu increases over the course of infection and is associated with predicted epitopes of the individual's MHC class I haplotype, suggesting CD8+ T cell pressure is the major driver of Vpu sequence diversity within the host. Despite this variability, the Vpu functions of targeting CD4 and counteracting both physical virus restriction and NF-κB activation by tetherin are rigorously maintained throughout HIV-1 infection. Only a minority of circulating alleles bear lesions in either of these activities at any given time, suggesting functional Vpu mutants are heavily selected against even at later stages of infection. Comparison of Vpu proteins defective for one or several functions reveals novel determinants of CD4 downregulation, counteraction of tetherin restriction, and inhibition of NF-κB signalling. These data affirm the importance of Vpu functions for in vivo persistence of HIV-1 within infected individuals, not simply for transmission, and highlight its potential as a target for antiviral therapy
Gamma-Ray Telescopes (in "400 Years of Astronomical Telescopes")
The last half-century has seen dramatic developments in gamma-ray telescopes,
from their initial conception and development through to their blossoming into
full maturity as a potent research tool in astronomy. Gamma-ray telescopes are
leading research in diverse areas such as gamma-ray bursts, blazars, Galactic
transients, and the Galactic distribution of aluminum-26.Comment: 11 pages, 6 figures/ in "400 Years of Astronomical Telescopes: A
Review of History, Science and Technology", ed. B.R. Brandl, R. Stuik, & J.K.
Katgert-Merkeli (Exp. Astron. 26, 111-122 [2009]
Extensive complement-dependent enhancement of HIV-1 by autologous non-neutralising antibodies at early stages of infection
Background: Non-neutralising antibodies to the envelope glycoprotein are elicited during acute HIV-1 infection and are abundant throughout the course of disease progression. Although these antibodies appear to have negligible effects on HIV-1 infection when assayed in standard neutralisation assays, they have the potential to exert either inhibitory or enhancing effects through interactions with complement and/or Fc receptors. Here we report that non-neutralising antibodies produced early in response to HIV-1 infection can enhance viral infectivity.Results: We investigated this complement-mediated antibody-dependent enhancement (C'-ADE) of early HIV infection by carrying out longitudinal studies with primary viruses and autologous sera derived sequentially from recently infected individuals, using a T cell line naturally expressing the complement receptor 2 (CR2; CD21). The C'-ADE was consistently observed and in some cases achieved infection-enhancing levels of greater than 350-fold, converting a low-level infection to a highly destructive one. C'-ADE activity declined as a neutralising response to the early virus emerged, but later virus isolates that had escaped the neutralising response demonstrated an increased capacity for enhanced infection by autologous antibodies. Moreover, sera with autologous enhancing activity were capable of C'ADE of heterologous viral isolates, suggesting the targeting of conserved epitopes on the envelope glycoprotein. Ectopic expression of CR2 on cell lines expressing HIV-1 receptors was sufficient to render them sensitive to C'ADE.Conclusions: Taken together, these results suggest that non-neutralising antibodies to the HIV-1 envelope that arise during acute infection are not 'passive', but in concert with complement and complement receptors may have consequences for HIV-1 dissemination and pathogenesis
PRIME-HF: Novel Exercise for Older Patients with Heart Failure. A Pilot Randomized Controlled Study
OBJECTIVES: To test the hypothesis that (1) older patients with heart failure (HF) can tolerate COMBined moderate-intensity aerobic and resistance training (COMBO), and (2) 4 weeks of Peripheral Remodeling through Intermittent Muscular Exercise (PRIME) before 4 weeks of COMBO will improve aerobic capacity and muscle strength to a greater extent than 8 weeks of COMBO. DESIGN: Prospective randomized parallel open-label blinded end point. SETTING: Single-site Australian metropolitan hospital. PARTICIPANTS: Nineteen adults (72.8 ± 8.4 years of age) with heart failure with reduced ejection fraction (HFrEF). INTERVENTION: Participants were randomized to 4 weeks of PRIME or COMBO (phase 1). All participants subsequently completed 4 weeks of COMBO (phase 2). Sessions were twice a week for 60 minutes. PRIME is a low-mass, high-repetition regime (40% one-repetition maximum [1RM], eight strength exercises, 5 minutes each). COMBO training involved combined aerobic (40%-60% of peak aerobic capacity [VO2peak ], up to 20 minutes) and resistance training (50-70% 1RM, eight exercises, two sets of 10 repetitions). MEASUREMENTS: We measured VO2peak , VO2 at anaerobic threshold (AT), and muscle voluntary contraction (MVC). RESULTS: The PRIME group significantly increased VO2peak after 8 weeks (2.4 mL/kg/min; 95% confidence interval [CI] = .7-4.1; P = .004), whereas the COMBO group showed minimal change (.2; 95% CI -1.5 to 1.8). This produced a large between-group effect size of 1.0. VO2 at AT increased in the PRIME group (1.6 mL/kg/min; 95% CI .0-3.2) but not in the COMBO group (-1.2; 95% CI -2.9 to .4), producing a large between-group effect size. Total MVC increased significantly in both groups in comparison with baseline; however, the change was larger in the COMBO group (effect size = .6). CONCLUSION: Traditional exercise approaches (COMBO) and PRIME improved strength. Only PRIME training produced statistically and clinically significant improvements to aerobic capacity. Taken together, these findings support the hypothesis that PRIME may have potential advantages for older patients with HFrEF and could be a possible alternative exercise modality
Evidence for variation in the effective population size of animal mitochondrial DNA
Background: It has recently been shown that levels of diversity in mitochondrial DNA are remarkably constant across animals of diverse census population sizes and ecologies, which has led to the suggestion that the effective population of mitochondrial DNA may be relatively constant. Results: Here we present several lines of evidence that suggest, to the contrary, that the effective population size of mtDNA does vary, and that the variation can be substantial. First, we show that levels of mitochondrial and nuclear diversity are correlated within all groups of animals we surveyed. Second, we show that the effectiveness of selection on non-synonymous mutations, as measured by the ratio of the numbers of non-synonymous and synonymous polymorphisms, is negatively correlated to levels of mitochondrial diversity. Finally, we estimate the effective population size of mitochondrial DNA in selected mammalian groups and show that it varies by at least an order of magnitude. Conclusions: We conclude that there is variation in the effective population size of mitochondria. Furthermore we suggest that the relative constancy of DNA diversity may be due to a negative correlation between the effective population size and the mutation rate per generation
Dark Force Detection in Low Energy e-p Collisions
We study the prospects for detecting a light boson X with mass m_X < 100 MeV
at a low energy electron-proton collider. We focus on the case where X
dominantly decays to e+ e- as motivated by recent "dark force" models. In order
to evade direct and indirect constraints, X must have small couplings to the
standard model (alpha_X 10 MeV).
By comparing the signal and background cross sections for the e- p e+ e- final
state, we conclude that dark force detection requires an integrated luminosity
of around 1 inverse attobarn, achievable with a forthcoming JLab proposal.Comment: 38 pages, 19 figures; v2, references adde
The diverse roles of mononuclear phagocytes in prion disease pathogenesis
Transmissible spongiform encephalopathies (TSEs), or prion diseases, are neurological diseases that can be transmitted through a number of different routes. A wide range of mammalian species are affected by the disease. After peripheral exposure, some TSE agents accumulate in lymphoid tissues at an early stage of disease prior to spreading to the nerves and the brain. Much research has focused on identifying the cells and molecules involved in the transmission of TSE agents from the site of exposure to the brain and several crucial cell types have been associated with this process. The identification of the key cells that influence the different stages of disease transmission might identify targets for therapeutic intervention. This review highlights the involvement of mononuclear phagocytes in TSE disease. Current data suggest these cells may exhibit a diverse range of roles in TSE disease from the transport or destruction of TSE agents in lymphoid tissues, to mediators or protectors of neuropathology in the brain
Continuous-wave room-temperature diamond maser
The maser, older sibling of the laser, has been confined to relative
obscurity due to its reliance on cryogenic refrigeration and high-vacuum
systems. Despite this it has found application in deep-space communications and
radio astronomy due to its unparalleled performance as a low-noise amplifier
and oscillator. The recent demonstration of a room-temperature solid- state
maser exploiting photo-excited triplet states in organic pentacene molecules
paves the way for a new class of maser that could find applications in
medicine, security and sensing, taking advantage of its sensitivity and low
noise. However, to date, only pulsed operation has been observed in this
system. Furthermore, organic maser molecules have poor thermal and mechanical
properties, and their triplet sub-level decay rates make continuous emission
challenging: alternative materials are therefore required. Therefore, inorganic
materials containing spin-defects such as diamond and silicon carbide have been
proposed. Here we report a continuous-wave (CW) room-temperature maser
oscillator using optically pumped charged nitrogen-vacancy (NV) defect centres
in diamond. This demonstration unlocks the potential of room-temperature
solid-state masers for use in a new generation of microwave devices.Comment: 7 pages, 4 figure
SPECIAL COMMUNICATION Health Industry Practices That Create Conflicts of Interest A Policy Proposal for Academic Medical Centers
market incentives in the United States is posing extraordinary challenges to the principles of medical professionalism. Physicians’ commitment to altruism, putting the interests of the patients first, scientific integrity, and an absence of bias in medical decision making now regularly come up against financial conflicts of interest. Arguably, the most challenging and extensive of these conflicts emanate from relationships between physicians and pharmaceutical companies and medical device manufacturers. 1 As part of the health care industry
- …