18 research outputs found

    Ultrasonic superharmonic imaging

    Get PDF

    Ultrasonic superharmonic imaging

    Get PDF

    Dual-Pulse Frequency Compounded Superharmonic Imaging

    No full text
    Tissue second-harmonic imaging is currently the default mode in commercial diagnostic ultrasound systems. A new modality, superharmonic imaging (SHI), combines the third through fifth harmonics originating from nonlinear wave propagation through tissue. SHI could further improve the resolution and quality of echographic images. The superharmonics have gaps between the harmonics because the transducer has a limited bandwidth of about 70% to 80%. This causes ghost reflection artifacts in the superharmonic echo image. In this work, a new dual-pulse frequency compounding (DPFC) method to eliminate these artifacts is introduced. In the DPFC SHI method, each trace is constructed by summing two firings with slightly different center frequencies. The feasibility of the method was established using a single-element transducer. Its acoustic field was modeled in KZK simulations and compared with the corresponding measurements obtained with a hydrophone apparatus. Subsequently, the method was implemented on and optimized for a setup consisting of an interleaved phased-array transducer (44 elements at 1 MHz and 44 elements at 3.7 MHz, optimized for echocardiography) and a programmable ultrasound system. DPFC SHI effectively suppresses the ghost reflection artifacts associated with imaging using multiple harmonics. Moreover, compared with the single-pulse third harmonic, DPFC SHI improved the axial resolution by 3.1 and 1.6 times at the -6-dB and -20-dB levels, respectively. Hence, DPFC offers the possibility of generating harmonic images of a higher quality at a cost of a moderate frame rate reduction

    Super-Harmonic Imaging: Development of an Interleaved Phased-Array Transducer

    No full text
    For several years, the standard in ultrasound imaging has been second-harmonic imaging. A new imaging technique dubbed "super-harmonic imaging" (SHI) was recently proposed. It takes advantage of the higher-third to fifth-harmonics arising from nonlinear propagation or ultrasound-contrast-agent (UCA) response. Next to its better suppression of near-field artifacts, tissue SHI is expected to improve axial and lateral resolutions resulting in clearer images than second-harmonic imaging. When SHI is used in combination with UCAs, a better contrast-to-tissue ratio can be obtained. The use of SHI implies a large dynamic range and requires a sufficiently sensitive array over a frequency range from the transmission frequency up to its fifth harmonic (bandwidth > 130%). In this paper, we present the characteristics and performance of a new interleaved dual frequency array built chiefly for SHI. We report the rationale behind the design choice, frequencies, aperture, and piezomaterials used. The array is efficient both in transmission and reception with well-behaved transfer functions and a combined -6-dB bandwidth of 144%. In addition, there is virtually no contamination of the harmonic components by spurious transducer transmission, due to low element-to-element crosstalk (< 30 dB) and a low transmission efficiency of the odd harmonics (< 46 dB). The interleaved array presented in this article possesses ideal characteristics for SHI and is suitable for other methods like second-harmonic, subharmonic, and second-order ultrasound field (SURF) imaging

    Single pulse frequency compounding protocol for superharmonic imaging

    No full text
    Second harmonic imaging is currently accepted as the standard in commercial echographic systems. A new imaging technique, coined as superharmonic imaging (SHI), combines the third till the fifth harmonics, arising during nonlinear sound propagation. It could further enhance the resolution and quality of echographic images. To meet the bandwidth requirement for SHI a dedicated phased array has been developed: a low frequency subarray, intended for transmission, interleaved with a high frequency subarray, used in reception. As the bandwidth of the elements is limited, the spectral gaps in between the harmonics cause multiple (ghost) reflection artifacts. A dual-pulse frequency compounding method aims at suppressing those artifacts at a price of a reduced frame rate. In this study we explore a possibility of performing frequency compounding within a single transmission. The traditional frequency compounding method suppresses the ripples by consecutively emitting two short Gaussian bursts with a slightly different center frequency. In the newly proposed method, the transmit aperture is divided into two parts: the first half is used to send a pulse at the lower center frequency, while the other half simultaneously transmits at a slightly higher center frequency. The suitability of the protocol for medical imaging applications in terms of the steering capabilities was performed in a simulation study with INCS and the hydrophone measurements. Moreover, an experimental study was carried out to find the optimal parameters for the clinical imaging protocol. The latter was subsequently used to obtain the images of a tissue mimicking phantom containing strongly reflecting wires. Additionally, the images of a human heart in the parasternal projection were acquired. The scanning aperture with the developed protocol amounts to approximately 90 degrees, which is sufficient to capture the cardiac structures in the standard anatomical projections. The theoretically estimated and experimentally measured grating lobe levels are equal to -28.3 dB and -35.9 dB, respectively. A considerable improvement in the axial resolution of the SHI component (0.73 mm) at -6 dB in comparison with the third harmonic (2.23 mm) was observed. A similar comparison in terms of the lateral resolution slightly favored the superharmonic component by 0.2 mm. Additionally, the images of the tissue mimicking phantom exhibited the absence of the multiple reflection artifacts. The in-vivo acquisition allows one to clearly observe the dynamic of the mitral valve leaflets. The new method is equally effective in eliminating the ripple artifacts associated with SHI as the dual-pulse technique, while the full frame rate is maintained

    Comparison of fundamental, second harmonic, and superharmonic imaging: A simulation study

    No full text
    In medical ultrasound, fundamental imaging (FI) uses the reflected echoes from the same spectral band as that of the emitted pulse. The transmission frequency determines the trade-off between penetration depth and spatial resolution. Tissue harmonic imaging (THI) employs the second harmonic of the emitted frequency band to construct images. Recently, superharmonic imaging (SHI) has been introduced, which uses the third to the fifth (super) harmonics. The harmonic level is determined by two competing phenomena: nonlinear propagation and frequency dependent attenuation. Thus, the transmission frequency yielding the optimal trade-off between the spatial resolution and the penetration depth differs for THI and SHI. This paper quantitatively compares the concepts of fundamental, second harmonic, and superharmonic echocardiography at their optimal transmission frequencies. Forward propagation is modeled using a 3D-KZK implementation and the iterative nonlinear contrast source (INCS) method. Backpropagation is assumed to be linear. Results show that the fundamental lateral beamwidth is the narrowest at focus, while the superharmonic one is narrower outside the focus. The lateral superharmonic roll-off exceeds the fundamental and second harmonic roll-off. Also, the axial resolution of SHI exceeds that of FI and THI. The far-field pulse-echo superharmonic pressure is lower than that of the fundamental and second harmonic. SHI appears suited for echocardiography and is expected to improve its image quality at the cost of a slight reduction in depth-of-field. (C) 2011 Acoustical Society of America. [DOI: 10.1121/1.3643815