35 research outputs found

    Anatomy Versus Physiology: Is Breast Lymphatic Drainage to the Internal Thoracic (Internal Mammary) Lymphatic System Clinically Relevant?

    Get PDF
    Approximately 15%−25% of breast lymphatic drainage passes through the internal thoracic (internal mammary) lymphatic system, draining the inner quadrants of the breast. This study aimed to use lymphosonography to identify sentinel lymph nodes (SLNs) in the axillary and internal thoracic lymphatic systems in patients with breast cancer. Seventy-nine patients received subcutaneous ultrasound contrast agent injections around the tumor. Lymphosonography was used to identify SLNs. In 14 of the 79 patients (17.7%), the tumor was located in the inner quadrant of the breast. Lymphosonography identified 217 SLNs in 79 patients, averaging 2.7 SLNs per patient. The 217 identified SLNs in the 79 patients were located in the axillary lymphatic system; none were located in the internal thoracic (internal mammary) lymphatic system, although it was expected in two to four patients (i.e., 4–11 SLNs). These results implied that SLNs associated with breast cancer are predominantly located in the axillary lymphatic system

    Subdermal Ultrasound Contrast Agent Injection for Sentinel Lymph Node Identification: An Analysis of Safety and Contrast Agent Dose in Healthy Volunteers.

    Get PDF
    Objectives—Mapping of the lymphatic chain for identification of the sentinel lymph node (SLN) is an important aspect of predicting outcomes for breast cancer patients, and it is usually performed as an intraoperative procedure using blue dye and/or radiopharmaceuticals agents. Recently the use of contrast-enhanced ultrasound (CEUS) has been proposed as an alternative imaging technique for this mapping. The objective of this study was to evaluate the use of subdermal administration of the ultrasound contrast agent Sonazoid (GE Healthcare) in terms of patient safety and to select the dose to be used for lymphatic applications in humans. Methods—This study was performed in 12 female volunteers that received bilateral subdermal injections of Sonazoid (1 or 2 ml doses) in the mid-upper outer quadrant of their breasts at two different time-points. CEUS was performed 0, 0.25, 0.5, 1, 2, 4, 6 and 24 hours post-injection to identify SLNs. Results—SLNs were identified within the first hour post-injection as enhanced structures and there was no significant difference by dose in the number of SLNs identified (p=0.74). Volunteers only experienced minor adverse experiences (AEs) that resolved completely without intervention by study completion. Conclusion—The subdermal use of Sonazoid in this study showed only minor local and non-significant AEs that were completely resolved without any intervention. Two different doses were compared with no significant differences observed between them. Hence, the lower dose studied (1 ml) was selected for use in future clinical studies

    A long-term study of the effects of antiviral therapy on survival of patients with HBV-associated hepatocellular carcinoma (HCC) following local tumor ablation.

    Get PDF
    The ultimate goal of antiviral therapy for chronic hepatitis B (CHB) is prevention of hepatocellular carcinoma (HCC). Earlier we reported favorable effects of antiviral therapy on survival of HCC patients following curative tumor ablation (Int J Cancer online 14 April 2010; doi: 10.1002/ijc.25382). It was the first observation made in the United States. We now report 12 year follow-up of this patient group. CHB patients with no prior antiviral therapy with a single HCC (≤ 7 cm) were studied. All patients underwent local tumor ablation as their first option. Patients diagnosed before 1999 received no antiviral treatment while those diagnosed after 1999 received antiviral treatment. Survival between the treated and untreated groups was compared. Among 555 HCC patients seen at our clinic between 1991 and 2013, 25 subjects were eligible. Nine subjects (all male patients, median age 53 years [46-66]) did not receive antiviral therapy while 16 (14 male patients, median age 56 years [20-73]) received treatment. Between the two groups, there was no difference in their median tumor size and levels of alpha-fetoprotein and albumin. However, the survival was significantly different (P = 0.001): the median survival of the untreated was 16 months (3-36 months) while that of the treated was 80 months (15-152 months). Fourteen of 16 treated patients are alive to date with two longest survivors alive for ≥ 151 months. In conclusion, concomitant antiviral therapy for CHB patients with HCC reduces and prevents new/recurrent tumor and improves survival. This novel treatment strategy offers an alternative to liver transplantation in patients with HBV-associated HCC

    FPGA implementation of a 32x32 autocorrelator array for analysis of fast image series

    Full text link
    With the evolving technology in CMOS integration, new classes of 2D-imaging detectors have recently become available. In particular, single photon avalanche diode (SPAD) arrays allow detection of single photons at high acquisition rates (\geq 100 kfps), which is about two orders of magnitude higher than with currently available cameras. Here we demonstrate the use of a SPAD array for imaging fluorescence correlation spectroscopy (imFCS), a tool to create 2D maps of the dynamics of fluorescent molecules inside living cells. Time-dependent fluorescence fluctuations, due to fluorophores entering and leaving the observed pixels, are evaluated by means of autocorrelation analysis. The multi-{\tau} correlation algorithm is an appropriate choice, as it does not rely on the full data set to be held in memory. Thus, this algorithm can be efficiently implemented in custom logic. We describe a new implementation for massively parallel multi-{\tau} correlation hardware. Our current implementation can calculate 1024 correlation functions at a resolution of 10{\mu}s in real-time and therefore correlate real-time image streams from high speed single photon cameras with thousands of pixels.Comment: 10 pages, 7 figure

    A Sonographer’s Step-by-Step Approach for Preventing Transmission of COVID-19

    Get PDF
    The 2019 novel coronavirus, known as COVID-19, has greatly affected the way sonographers care for their patients. Sonography can be a useful imaging tool for surveillance and diagnosis of various conditions associated with COVID-19 patients or patients under investigation (PUIs). Currently, there are limited resources and protocols for preventing the transmission of COVID-19 from ultrasound equipment. Our institution has created a detailed protocol for scanning COVID-19 patients or PUIs to address this important issue

    Accreditation Status and Geographic Location of Outpatient Echocardiographic Testing Facilities Among Medicare Beneficiaries: The VALUE-ECHO Study

    No full text
    Accreditation of echocardiographic testing facilities by the Intersocietal Accreditation Commission (IAC) is supported by the American College of Cardiology and American Society of Echocardiography. However, limited information exists on the accreditation status and geographic distribution of echocardiographic facilities in the United States. Our study aimed to identify (1) the proportion of outpatient echocardiography facilities used by Medicare beneficiaries that are IAC accredited, (2) their geographic distribution, and (3) variations in procedure type and volume by accreditation status. As part of the VALUE-ECHO (Value of Accreditation, Location, and Utilization Evaluation-Echocardiography) study, we examined the proportion of IAC-accredited echocardiographic facilities performing outpatient echocardiography in the 2013 Centers for Medicare and Medicaid Services outpatient limited data set (100% sample) and their geographic distribution using geocoding in ArcGIS (ESRI, Redlands, CA). Among 4573 outpatient facilities billing Medicare for echocardiographic testing in 2013, 99.6% (n = 4554) were IAC accredited (99.7% in the 50 US states and 86.2% in Puerto Rico). The proportion IAC-accredited echocardiographic facilities varied by region, with 98.7%, 99.9%, 99.9%, 99.5%, and 86.2% of facilities accredited in the Northeast, South, Midwest, West, and Puerto Rico, respectively (P < .01, Fisher exact test). Of all echocardiographic outpatient procedures conducted (n = 1,890,156), 99.8% (n = 1,885,382) were performed in IAC-accredited echocardiographic facilities. Most procedures (90.9%) were transthoracic echocardiograms, of which 99.7% were conducted in IAC-accredited echocardiographic facilities. Almost all outpatient echocardiographic facilities billed by Medicare are IAC accredited. This accreditation rate is substantially higher than previously reported for US outpatient vascular testing facilities (13% IAC accredited). The uniformity of imaging and interpretation protocols from a single accrediting body is important to facilitate optimal cardiovascular care