275 research outputs found
Comportamento ''in vitro" de uma bactéria fitopatogênica frente a diversos antibióticos
The present paper deals with study of the resistance against five antibiotics in a phytopathogenic bacterium Xanthomonas campestris (Pammel) Dowson. When the antibiotics were added to the solid medium in which the bacteria were grown, the colonies resistant to the streptomycin and erythromycin appeared even in the highest concentration used; as to the penicillin, aureomycin and cloranfenicol when in concentrations higher than 200 mcg/ml, 0,3 mcg/ml and 128 mcg/ml respectively, resistant colonies did not appear. So, the results show that the penicillin was the least efficient antibiotic and aureomycin the most effetive to Xanthomonas campestris.Foi estudada a resistência da bactéria fitopatogênica Xanthomonas campestris com relação a cinco antibióticos. Quando os antibióticos foram adicionados ao meio sólido no qual a bactéria iria se desenvolver, colônias resistentes à estreptomicina e éritromicina, apareceram até nas mais altas concentrações usadas. No caso da penicilina, aureomicina e cloranfenicol, em concentrações superiores a 200 mcg/ml, 0,3 mcg/ml e 128 mcg/ml respectivamente, não apareceram colônias resistentes. Os resultados mostraram que a penicilina foi o antibiótico menos efetivo e a aureomicina a mais efetiva em inibir o crescimento de X. campestris. Os resultados sugerem também que o modêlo de resistência à estreptomicina e éritromicina é o de um só passo enquanto que o modêlo de resistência aos três outros antibióticos ensaiados, é o de múltiplos passos
Asociación entre prácticas de ordeño y recuento de organismos psicrótrofos en leche de tanque de frío
The objective of this work was to determine on-farm risk factors for psychrotrophic bacterial counts in bulk tank milk from dairy farms in Argentina. Raw milk samples from bulk tanks of 27 dairy farms were examined for total psychrotrophic counts (TPC), proteolytic psychrotrophic counts (PPC) and lipolytic psychrotrophic counts (LPC) (dependent or outcome variables). A survey recording infrastructure conditions, milking equipment and milking management (independent variables) was performed. Bivariate association proofs and logistic regression analyses were used to determine association between independent variables and psychrotrophic bacterial counts. Milk cooled in plate heat exchangers or barrel tanks were 16.39 and 10.52 times more likely to yield TPC and PPC above the standard established for high quality milk compared with milk cooled in bulk tanks, respectively. Periodic cleaning of cooling tanks (3 times a week or daily) was associated with lower TPC (approximately 1.5 log CFU/ml) than weekly cleaning frequency and farms where milkers did not wash their hands during milking time were 7.81 times more likely to have higher PPC. No association was found between LPC and any of the independent variables. The only variable associated with TPC and PPC in a logistic regression model was the refrigeration system used on the farm. Dairy farms that possessed bulk milk cooling tanks yielded the lowest bacterial counts. Results of this study highlight the importance of both the type of cooling system used on the farm and its adequate hygienic maintenance for obtaining low pshychrotrophic counts at dairy farm.El objetivo del trabajo fue determinar los factores de riesgo para altos recuentos de organismos psicrótrofos en leche de tanques de tambos de la Argentina. Se examinaron muestras de leche cruda de tanques de frío de 27 tambos, y se realizó el recuento de organismos psicrótrofos totales (PT), de psicrótrofos proteolíticos (PP) y de psicrótrofos lipolíticos (PL) (variables dependientes). Se realizó una encuesta para registrar las condiciones de infraestructura, el equipo de ordeño y las prácticas de ordeño (variables independientes). Se utilizaron pruebas bivariadas de asociación y regresión logística para determinar la asociación entre las variables independientes y los recuentos de organismos psicrótrofos. La leche enfriada en sistemas de placas de intercambio o tanques tipo cuba tuvo una probabilidad mayor de dar recuentos elevados de PT y PP (16,39 y 10,52) comparada con la enfriada en tanques tipo "panza fría". La limpieza periódica del equipo de frío (3 veces por semana o diariamente) se asoció con bajos recuentos de PT (aproximadamente 1,5 log de UFC/ml). Los tambos cuyos ordeñadores no se higienizaban las manos durante el ordeño tuvieron una probabilidad 7,81 veces mayor de tener recuentos elevados de PP. No se encontró asociación entre el recuento de PL y las variables independientes. La única variable asociada con los recuentos de PT y PP en el modelo de regresión logística fue el sistema de enfriamiento utilizado en el tambo. El tipo de sistema de refrigeración usado y su adecuado mantenimiento higiénico son importantes para la obtención de leche con baja carga de organismos psicrótrofos en el tambo.Fil: Molineri, Ana Inés. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación de la Cadena Láctea. - Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela. Instituto de Investigación de la Cadena Láctea; ArgentinaFil: Signorini Porchietto, Marcelo Lisandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación de la Cadena Láctea. - Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela. Instituto de Investigación de la Cadena Láctea; Argentina. Universidad Nacional del Litoral; ArgentinaFil: Cuatrín, Alejandra L.. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; ArgentinaFil: Canavesio, Vilma R.. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; ArgentinaFil: Neder, Veronica. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; ArgentinaFil: Russi, Norma B.. Universidad Nacional del Litoral; ArgentinaFil: Bonazza, Julio C.. Universidad Nacional del Litoral; ArgentinaFil: Calvinho, Luis F.. Universidad Nacional del Litoral; Argentina. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; Argentin
Asociación entre prácticas de ordeño y recuento de organismos psicrótrofos en leche de tanque de frío
The objective of this work was to determine on-farm risk factors for psychrotrophic bacterial counts in bulk tank milk from dairy farms in Argentina. Raw milk samples from bulk tanks of 27 dairy farms were examined for total psychrotrophic counts (TPC), proteolytic psychrotrophic counts (PPC) and lipolytic psychrotrophic counts (LPC) (dependent or outcome variables). A survey recording infrastructure conditions, milking equipment and milking management (independent variables) was performed. Bivariate association proofs and logistic regression analyses were used to determine association between independent variables and psychrotrophic bacterial counts. Milk cooled in plate heat exchangers or barrel tanks were 16.39 and 10.52 times more likely to yield TPC and PPC above the standard established for high quality milk compared with milk cooled in bulk tanks, respectively. Periodic cleaning of cooling tanks (3 times a week or daily) was associated with lower TPC (approximately 1.5 log CFU/ml) than weekly cleaning frequency and farms where milkers did not wash their hands during milking time were 7.81 times more likely to have higher PPC. No association was found between LPC and any of the independent variables. The only variable associated with TPC and PPC in a logistic regression model was the refrigeration system used on the farm. Dairy farms that possessed bulk milk cooling tanks yielded the lowest bacterial counts. Results of this study highlight the importance of both the type of cooling system used on the farm and its adequate hygienic maintenance for obtaining low pshychrotrophic counts at dairy farm.El objetivo del trabajo fue determinar los factores de riesgo para altos recuentos de organismos psicrótrofos en leche de tanques de tambos de la Argentina. Se examinaron muestras de leche cruda de tanques de frío de 27 tambos, y se realizó el recuento de organismos psicrótrofos totales (PT), de psicrótrofos proteolíticos (PP) y de psicrótrofos lipolíticos (PL) (variables dependientes). Se realizó una encuesta para registrar las condiciones de infraestructura, el equipo de ordeño y las prácticas de ordeño (variables independientes). Se utilizaron pruebas bivariadas de asociación y regresión logística para determinar la asociación entre las variables independientes y los recuentos de organismos psicrótrofos. La leche enfriada en sistemas de placas de intercambio o tanques tipo cuba tuvo una probabilidad mayor de dar recuentos elevados de PT y PP (16,39 y 10,52) comparada con la enfriada en tanques tipo "panza fría". La limpieza periódica del equipo de frío (3 veces por semana o diariamente) se asoció con bajos recuentos de PT (aproximadamente 1,5 log de UFC/ml). Los tambos cuyos ordeñadores no se higienizaban las manos durante el ordeño tuvieron una probabilidad 7,81 veces mayor de tener recuentos elevados de PP. No se encontró asociación entre el recuento de PL y las variables independientes. La única variable asociada con los recuentos de PT y PP en el modelo de regresión logística fue el sistema de enfriamiento utilizado en el tambo. El tipo de sistema de refrigeración usado y su adecuado mantenimiento higiénico son importantes para la obtención de leche con baja carga de organismos psicrótrofos en el tambo.Fil: Molineri, Ana Inés. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación de la Cadena Láctea. - Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela. Instituto de Investigación de la Cadena Láctea; ArgentinaFil: Signorini Porchietto, Marcelo Lisandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación de la Cadena Láctea. - Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela. Instituto de Investigación de la Cadena Láctea; Argentina. Universidad Nacional del Litoral; ArgentinaFil: Cuatrín, Alejandra L.. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; ArgentinaFil: Canavesio, Vilma R.. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; ArgentinaFil: Neder, Veronica. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; ArgentinaFil: Russi, Norma B.. Universidad Nacional del Litoral; ArgentinaFil: Bonazza, Julio C.. Universidad Nacional del Litoral; ArgentinaFil: Calvinho, Luis F.. Universidad Nacional del Litoral; Argentina. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Santa Fe. Estación Experimental Agropecuaria Rafaela; Argentin
Single electron quantum tomography in quantum Hall edge channels
We propose a quantum tomography protocol to measure single electron coherence
in quantum Hall edge channels and therefore access for the first time the wave
function of single electron excitations propagating in ballistic quantum
conductors. Its implementation would open the way to quantitative studies of
single electron decoherence and would provide a quantitative tool for analyzing
single to few electron sources. We show how this protocol could be implemented
using ultrahigh sensitivity noise measurement schemes.Comment: Version 3: long version (7 figures): corrections performed and
references have been added. Figures reprocessed for better readabilit
Probing quantum and thermal noise in an interacting many-body system
The probabilistic character of the measurement process is one of the most
puzzling and fascinating aspects of quantum mechanics. In many-body systems
quantum mechanical noise reveals non-local correlations of the underlying
many-body states. Here, we provide a complete experimental analysis of the
shot-to-shot variations of interference fringe contrast for pairs of
independently created one-dimensional Bose condensates. Analyzing different
system sizes we observe the crossover from thermal to quantum noise, reflected
in a characteristic change in the distribution functions from Poissonian to
Gumbel-type, in excellent agreement with theoretical predictions based on the
Luttinger liquid formalism. We present the first experimental observation of
quasi long-range order in one-dimensional atomic condensates, which is a
hallmark of quantum fluctuations in one-dimensional systems. Furthermore, our
experiments constitute the first analysis of the full distribution of quantum
noise in an interacting many-body system
The Borexino detector at the Laboratori Nazionali del Gran Sasso
Borexino, a large volume detector for low energy neutrino spectroscopy, is
currently running underground at the Laboratori Nazionali del Gran Sasso,
Italy. The main goal of the experiment is the real-time measurement of sub MeV
solar neutrinos, and particularly of the mono energetic (862 keV) Be7 electron
capture neutrinos, via neutrino-electron scattering in an ultra-pure liquid
scintillator. This paper is mostly devoted to the description of the detector
structure, the photomultipliers, the electronics, and the trigger and
calibration systems. The real performance of the detector, which always meets,
and sometimes exceeds, design expectations, is also shown. Some important
aspects of the Borexino project, i.e. the fluid handling plants, the
purification techniques and the filling procedures, are not covered in this
paper and are, or will be, published elsewhere (see Introduction and
Bibliography).Comment: 37 pages, 43 figures, to be submitted to NI
Synthesis and characterisation of new MO(OH)2 (M = Zr, Hf) oxyhydroxides and related Li2MO3 salts
Two new solid MO(OH)2 (M = Zr, Hf) oxyhydroxides have been synthesised by an ion-exchange reaction from Li2MO3 (M = Zr, Hf) precursors obtained by a citrate combustion technique. The crystal structure of the oxyhydroxides has been solved by direct methods and refined using Rietveld full profile fitting based on X-ray powder diffraction data. Both oxyhydroxides crystallize in a P21/c monoclinic unit cell and have a structure resembling that of the related salts. Detailed characterisation of the fine-structure features and chemical bonding in precursors and oxyhydroxide powders has been performed using vibrational spectroscopy, nuclear magnetic resonance spectroscopy, scanning electron microscopy, pair distribution function analysis and quantum-chemical modelling
- …