6 research outputs found

    Effect of vitamin D replacement in chronic obstructive pulmonary disease patients with vitamin D deficiency

    Get PDF
    Introduction: Vitamin D deficiency is prevalent among patients with chronic obstructive pulmonary disease (COPD) and comes to be more frequent with increased disease severity. We aimed to assess the role of vitamin D supplementation in patients with severe COPD. Patients and methods: We studied 30 patients with severe COPD and vitamin D deficiency. All patients received oral vitamin D3 50,000 IU once weekly for 8 weeks, followed by a daily dose of 800 IU thereafter. Pulmonary function tests, six minute walk test (6MWT), maximum inspiratory pressure (MIP), maximum expiratory pressure (MEP), C-reactive protein (CRP), and serum vitamin D level were assessed at the start of the study and 1 year later. The frequency of exacerbations was recorded a year before and a year after vitamin D supplementation. Results: The mean serum vitamin D level was 11.80 ± 2.40 ng/dl and reached 55.30 ± 5.65 ng/dl a year after vitamin D intake (p < 0.001). We found a significant improvement in dyspnea scale (p < 0.003), 6MWT (p < 0.001), MVV (p < 0.001), MIP (p = 0.006), MEP (p < 0.001), coupled with a decrease in disease exacerbations (p < 0.001) and CRP (p < 0.001) a year after vitamin D replacement. However, the FEV1 and FVC did not differ significantly. Conclusion: Vitamin D replacement improved dyspnea, physical performance and decreased the frequency of exacerbation in severe COPD patients with vitamin D deficiency

    CT-guided biopsy versus conventional Abram’s needle biopsy in malignant pleural effusion

    Get PDF
    Objective: We aimed to evaluate CT guided biopsy (CTGB) vs. standard closed pleural biopsy (CPB) in the histopathological diagnosis of the type of malignancy in patients with malignant pleural effusion. Patients and methods: We studied 31 patients (21 male and 10 female) with malignant pleural effusion diagnosed by aspiration cytology and admitted to the medical ward of a general teaching hospital over a period of 1 year. Patients were randomized into two groups: group 1 (n = 16) underwent CTGB biopsy and group 2 (n = 15) underwent Abram’s CPB. The diagnostic yield of both methods was compared. Results: The mean age of patients was 54 ± 16 years. History of smoking was obtained in 15 (48.4%) patients. Dyspnea was reported in 22 (71%) and chest pain in 15 (48.4%). Malignant pleural effusion was left-sided in 17 (54.8%), and massive in 21 (67.7%) patients. Of note, CT imaging revealed parietal pleura as a tumor site in 20 (64.5%) patients. Pathological diagnosis of the type of malignancy was achieved in 14 (87.5%) of group 1 using CTGB and 6 (40%) of group 2 patients using Abram’s CPB. The diagnostic value of CTGB was significantly higher than CPB (P = 0.009). Conclusion: CT-guided biopsy was found to be a reliable and safe method in the histopathological diagnosis of malignant pleural effusion. Its diagnostic potential was much superior to the standard closed pleural biopsy

    Impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional approach on rates of ventilator-associated pneumonia in intensive care units of two hospitals in Kuwait

    No full text
    Objective: To analyse the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional approach (IMA) on ventilator-associated pneumonia (VAP) rates in three intensive care units (ICUs) from two hospitals in Kuwait City from January 2014 to March 2015.Design: A prospective, before-after study on 2507 adult ICU patients. During baseline, we performed outcome surveillance of VAP applying CDC/NHSN definitions. During intervention, we implemented the IMA through the INICC Surveillance Online System (ISOS), which included: (1) a bundle of infection prevention interventions; (2) education; (3) outcome surveillance; and (4) feedback on VAP rates and consequences. Logistic regression analysis was performed to estimate the effect of the intervention on VAP, controlling for potential bias.Results: During baseline, 1990 mechanical ventilator (MV)-days and 14 VAPs were recorded, accounting for 7.0 VAPs per 1000 MV-days. During intervention, 9786 MV-days and 35 VAPs were recorded, accounting for 3.0 VAPs per 1000 MV-days. The VAP rate was reduced by 57.1% (incidence-density ratio = 0.51; 95% CI = 0.28-0.93; p = 0.042). Logistic regression showed a significant reduction in VAP rate during the intervention phase (OR = 0.39, 95% CI = 0.18-0.83), with 61% effectiveness.Conclusions: Implementing IMA through ISOS was associated with a significant reduction in the VAP rate in Kuwait ICUs.Fil: Al Mousa, Haifaa Hassan. Ministry of Health; KuwaitFil: Omar, Abeer Aly. Ministry of Health; KuwaitFil: Rosenthal, VĂ­ctor Daniel. International Nosocomial Infection Control Consortium; ArgentinaFil: Salama, Mona Foda. Mubarak Al Kabir Hospital; Kuwait. University of Mansoura; EgiptoFil: Aly, Nasser Yehia. Farwaniya Hospital; Kuwait. University of Alexandria; EgiptoFil: El Dossoky Noweir, Mohammad. Farwaniya Hospital; KuwaitFil: Rebello, Flavie Maria. Mubarak Al Kabir Hospital; KuwaitFil: Narciso, Dennis Malungcot. Mubarak Al Kabir Hospital; KuwaitFil: Sayed, Amani Fouad. Farwaniya Hospital; KuwaitFil: Kurian, Anu. Farwaniya Hospital; KuwaitFil: George, Sneha Mary. Farwaniya Hospital; KuwaitFil: Mohamed, Amna Mostafa. Farwaniya Hospital; KuwaitFil: Ramapurath, Ruby Jose. Farwaniya Hospital; KuwaitFil: Varghese, Suga Thomas. Farwaniya Hospital; KuwaitFil: Orellano, Pablo Wenceslao. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas; Argentina. International Nosocomial Infection Control Consortium; Argentina. Universidad TecnolĂłgica Nacional; Argentin

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN
    corecore