338 research outputs found

    A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning

    Get PDF
    A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat, and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol, and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, the calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer accuracy, simplicity, and specificity required for a standard in radiotherapy treatment planning, in particular, with heavy charged particles

    Potential lethal damage repair in glioblastoma cells irradiated with ion beams of various types and levels of linear energy transfer

    Get PDF
    Glioblastoma (GBM), a Grade IV brain tumour, is a well-known radioresistant cancer. To investigate one of the causes of radioresistance, we studied the capacity for potential lethal damage repair (PLDR) of three altered strains of GBM: T98G, U87 and LN18, irradiated with various ions and various levels of linear energy transfer (LET). The GBM cells were exposed to 12C and 28Si ion beams with LETs of 55, 100 and 200 keV/μm, and with X-ray beams of 1.7 keV/μm. Mono-energetic 12C ions and 28Si ions were generated by the Heavy Ion Medical Accelerator at the National Institute of Radiological Science, Chiba, Japan. Clonogenic assays were used to determine cell inactivation. The ability of the cells to repair potential lethal damage was demonstrated by allowing one identical set of irradiated cells to repair for 24 h before subplating. The results show there is definite PLDR with X-rays, some evidence of PLDR at 55 keV/μm, and minimal PLDR at 100 keV/μm. There is no observable PLDR at 200 keV/μm. This is the first study, to the authors’ knowledge, demonstrating the capability of GBM cells to repair potential lethal damage following charged ion irradiations. It is concluded that a GBM’s PLDR is dependent on LET, dose and GBM strain; and the more radioresistant the cell strain, the greater the PLDR

    Correction factors to convert microdosimetry measurements in silicon to tissue in \u3csup\u3e12\u3c/sup\u3eC ion therapy

    Get PDF
    Silicon microdosimetry is a promising technology for heavy ion therapy (HIT) quality assurance, because of its sub-mm spatial resolution and capability to determine radiation effects at a cellular level in a mixed radiation field. A drawback of silicon is not being tissue-equivalent, thus the need to convert the detector response obtained in silicon to tissue. This paper presents a method for converting silicon microdosimetric spectra to tissue for a therapeutic 12C beam, based on Monte Carlo simulations. The energy deposition spectra in a 10 μm sized silicon cylindrical sensitive volume (SV) were found to be equivalent to those measured in a tissue SV, with the same shape, but with dimensions scaled by a factor κ equal to 0.57 and 0.54 for muscle and water, respectively. A low energy correction factor was determined to account for the enhanced response in silicon at low energy depositions, produced by electrons. The concept of the mean path length (lPath) to calculate the lineal energy was introduced as an alternative to the mean chord length (l) because it was found that adopting Cauchy\u27s formula for the (l) was not appropriate for the radiation field typical of HIT as it is very directional (lPath) can be determined based on the peak of the lineal energy distribution produced by the incident carbon beam. Furthermore it was demonstrated that the thickness of the SV along the direction of the incident 12C ion beam can be adopted as (lPath). The tissue equivalence conversion method and (lPath) were adopted to determine the RBE10, calculated using a modified microdosimetric kinetic model, applied to the microdosimetric spectra resulting from the simulation study. Comparison of the RBE10 along the Bragg peak to experimental TEPC measurements at HIMAC, NIRS, showed good agreement. Such agreement demonstrates the validity of the developed tissue equivalence correction factors and of the determination of (lPath)

    Present developments in reaching an international consensus for a model-based approach to particle beam therapy

    Get PDF
    Particle beam therapy (PBT), including proton and carbon ion therapy, is an emerging innovative treatment for cancer patients. Due to the high cost of and limited access to treatment, meticulous selection of patients who would benefit most from PBT, when compared with standard X-ray therapy (XRT), is necessary. Due to the cost and labor involved in randomized controlled trials, the model-based approach (MBA) is used as an alternative means of establishing scientific evidence in medicine, and it can be improved continuously. Good databases and reasonable models are crucial for the reliability of this approach. The tumor control probability and normal tissue complication probability models are good illustrations of the advantages of PBT, but pre-existing NTCP models have been derived from historical patient treatments from the XRT era. This highlights the necessity of prospectively analyzing specific treatment-related toxicities in order to develop PBT-compatible models. An international consensus has been reached at the Global Institution for Collaborative Research and Education (GI-CoRE) joint symposium, concluding that a systematically developed model is required for model accuracy and performance. Six important steps that need to be observed in these considerations include patient selection, treatment planning, beam delivery, dose verification, response assessment, and data analysis. Advanced technologies in radiotherapy and computer science can be integrated to improve the efficacy of a treatment. Model validation and appropriately defined thresholds in a cost-effectiveness centered manner, together with quality assurance in the treatment planning, have to be achieved prior to clinical implementation

    Thin Silicon Microdosimeter utilizing 3D MEMS Fabrication Technology: Charge Collection Study and its application in mixed radiation fields

    Get PDF
    New 10-μm-thick silicon microdosimeters utilizing 3-D technology have been developed and investigated in this paper. The TCAD simulations were carried out to understand the electrical properties of the microdosimeters\u27 design. A charge collection study of the devices was performed using 5.5-MeV He2+ ions which were raster scanned over the surface of the detectors and the charge collection median energy maps were obtained and the detection yield was also evaluated. The devices were tested in a 290 MeV/u carbon ion beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC) in Japan. Based on the microdosimetric measurements, the quality factor and dose equivalent out of field were obtained in a mixed radiation field mimicking the radiation environment for spacecraft in deep space

    Focal dose escalation using FDG-PET-guided intensity-modulated radiation therapy boost for postoperative local recurrent rectal cancer: a planning study with comparison of DVH and NTCP

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the safety of focal dose escalation to regions with standardized uptake value (SUV) >2.0 using intensity-modulated radiation therapy (IMRT) by comparison of radiotherapy plans using dose-volume histograms (DVHs) and normal tissue complication probability (NTCP) for postoperative local recurrent rectal cancer</p> <p>Methods</p> <p>First, we performed conventional radiotherapy with 40 Gy/20 fr. (CRT 40 Gy) for 12 patients with postoperative local recurrent rectal cancer, and then we performed FDG-PET/CT radiotherapy planning for those patients. We defined the regions with SUV > 2.0 as biological target volume (BTV) and made three boost plans for each patient: 1) CRT boost plan, 2) IMRT without dose-painting boost plan, and 3) IMRT with dose-painting boost plan. The total boost dose was 20 Gy. In IMRT with dose-painting boost plan, we increased the dose for BTV+5 mm by 30% of the prescribed dose. We added CRT boost plan to CRT 40 Gy (<it>summed plan 1</it>), IMRT without dose-painting boost plan to CRT 40 Gy (<it>summed plan 2</it>) and IMRT with dose-painting boost plan to CRT 40 Gy (<it>summed plan 3</it>), and we compared those plans using DVHs and NTCP.</p> <p>Results</p> <p>D<sub>mean </sub>of PTV-PET and that of PTV-CT were 26.5 Gy and 21.3 Gy, respectively. V<sub>50 </sub>of small bowel PRV in <it>summed plan 1 </it>was significantly higher than those in other plans ((<it>summed plan 1 </it>vs. <it>summed plan 2 </it>vs. <it>summed plan 3</it>: 47.11 ± 45.33 cm<sup>3 </sup>vs. 40.63 ± 39.13 cm<sup>3 </sup>vs. 41.25 ± 39.96 cm<sup>3</sup>(p < 0.01, respectively)). There were no significant differences in V<sub>30</sub>, V<sub>40</sub>, V<sub>60</sub>, D<sub>mean </sub>or NTCP of small bowel PRV.</p> <p>Conclusions</p> <p>FDG-PET-guided IMRT can facilitate focal dose-escalation to regions with SUV above 2.0 for postoperative local recurrent rectal cancer.</p

    Characteristics of carbon beam

    No full text
    Characteristics of Carbon Ion Beam- Physics in C-Ion RT at NIRS / HIMAC -Naruhiro MatsufujiNational Institute of Radiological Sciences, Research Center for Charged Particle Therapy\nAbstractPhysics is expected to play an important role in utilizing heavy ions for radiotherapy and further improvement or optimization. Technical improvements and accumulated knowledge in the behaviour of heavy ions promote the improvements in various aspects related to the physics in carbon ion radiotherapy (C-ion RT) at HIMAC such as beam or biological model. The production of secondary neutron is also of concern from the viewpoint of high QOL after the C-ion RT. Those recent status and updates related to the medical physics for ongoing C-ion RT at HIMAC are reported.\nIntroductionElevating energy loss toward range end associated with increasing biological effectiveness renders heavy ions such as carbon ions attractive for treating deep-seated tumors. The modality was first realized as a pioneering study at the Lawrence Berkeley Laboratory (LBL) in the United States. Next to LBL, National Institute of Radiological Sciences (NIRS) of Japan started the heavy ion radiotherapy at Heavy Ion Medical Accelerator in Chiba (HIMAC) since 1994 with carbon ions. The outcome in the past 16 years is proving the expectation toward heavy ion radiotherapy as true.The absorbed dose, quantity of energy given by radiation, is the most fundamental parameter to be controlled in radiotherapy. It is true even in the C-ion RT; however, different from conventional radiations, therapeutic beam contains various kind and energy of particles due to the nuclear reactions between incident carbon ions and target nuclei. It makes the spatial distribution of therapeutic beams and its biological effectiveness complex in comparison to conventional radiations. In order to make the best use of heavy ions for radiotherapy, it is indispensable to understand the behaviour of the therapeutic beam precisely.\nMaterials and MethodsBeam modelBiological effectiveness of the charged particles is, as the first approximation, considered proportional to LET (linear energy transfer), the amount of energy released in a unit length. However, even LET is identical, lateral distribution of energy deposition (track structure) is different between different particle species in microscopic viewpoint. This difference in the track structure causes a particle-species dependency in biological response when expressed as a function of LET, and makes it indispensable to understand the radiation quality, i.e., the fluence and LET on each particle species at any region of interest for a precise estimation of the biological effect of the therapeutic beam.In our current passive beam delivery, lateral distribution of the radiation quality is, as the first approximation, regarded as constant due to the sharp falloff of penumbra and the equilibrium between incoming and outgoing particles to and from the region of interest in the irradiation field. Fig. 1 and 2 show measured axial fluence and LET distribution of therapeutic carbon beam measured at HIMAC (1). Our current beam model for the passive beam delivery is based on this one-dimensional distribution of absorbed dose as well as radiation qualities.In order to estimate the distribution of radiation quality in the irradiation field in detail, or in order to form the irradiation field by a scanning with narrow pencil-like beams, it is strongly required to understand the spatial distribution of the radiation quality. The deflection of primary particles in a medium is well described by Molieres multiple scattering theory (2) while multiple scattering alone is not sufficient to account for the distribution of the fragment particles. We measured the angular distribution of the fragment particles from mono-energetic 290 MeV/n 12C beam through a nuclear reaction in a thick water target and revealed that the deflection of fragment particles in a substance is reproduced well when considering one additional term representing an extra lateral kick at the production point of the fragment to the Molieres multiple scattering formula (3). This additional term can be explained as a transfer of the intra-nucleus Fermi momentum of a projectile to the fragment, and its extent obeys the expectation derived from the Goldhaber model (4). Based on these studies, a semi-analytical beam transportation code was developed for energetic heavy-ion beams by which the three dimensional distribution of radiation quality can be calculated for each species of particles (5). In the code the production of secondary and tertiary fragments is considered and the effects of Fermi momentum transfer is taken into account at their production point. Despite its simplicity, the developed code can reproduce the experimental result well. We have installed the code to our new treatment planning system for the coming scanning irradiation. \n Fig. 1 Particle composition of therapeutic 290Fig. 2 Axial LET distribution of the therapeutic MeV/n of carbon beam (SOBP 60 mm) as a 290 MeV/n of carbon beam (SOBP 60 mm) in function of thickness in water.water.\nBiological response modelAmong various cell lines, HSG (human salivary gland) was chosen as our standard in our current model (6). The response of the HSG cell has a small shoulder in their survival curve, and belongs to the early-responding tissues. Then, spread-out Bragg peak (SOBP) was designed to achieve a flat cell survival probability (10%) for the HSG cells in the entire SOBP region. The LQ (linear-quadratic) model is used to reproduce the HSG response for therapeutic beam including high- and low-LET particles. The parameters &#61537; and &#61538; in the LQ model were obtained as dose-averaging coefficients &#61537; and &#61538; of monoenergetic beams over the spectrum of the SOBP beam. The response of the HSG cells for carbon SOBP beam is found to be equivalent at the point where the dose-averaged LET value is 80 keV/&#61549;m to the NIRS neutron beam that was once used for radiotherapy. The relationship between absorbed dose distributions and biological response of the HSG cells is regarded relatively identical in the clinical situation, i.e., if we realize the flat biological response in the SOBP region for the HSG cells, clinical response should be also flat, though the RBE value can be different. As the clinical RBE of the fast neutron radiotherapy at NIRS was observed as 3.0, the clinical dose distribution of the therapeutic carbon beam is finally deduced by equally multiplying a fixed factor, the ratio between the clinical and biological RBE value at the point where the dose-averaged LET is 80 keV/&#61549;m, to the entire biological SOBP. This scheme is summarized as fig. 3. Then ridge filters were manufactured to realize the various widths of SOBP for C-ion RT at HIMAC regardless of tumor type or fraction size in order to understand the clinical response of various tissues against carbon ions. The appropriateness of this SOBP design has been confirmed through an analysis of our clinical result in terms of tumor control probability (7). From fundamental viewpoint, biological effect caused by radiations is considered to be originated from lesions caused in DNA strands. The DNA has a diameter of about 2nm and enclosed in a cell nucleus that is about 10&#61472;&#61549;m in diameter. The energy deposition in such a minute region is strongly affected by statistic randomness. Here the LET, a macroscopic averaged value, is no longer appropriate to tell the life and death of a cell. Microdosimetric-kinetic model (MKM) (8) is one of the attempts to explain the biological effect of radiations based on the microdosimetric information. Damage to a cell is characterized with a specific energy or a lineal energy (corresponds to absorbed dose and LET in a macroscopic view, respectively) in domains assumed inside a cell nucleus. As the microdosimetric quantities are assessable by measurement, we can estimate the biological effectiveness of the therapeutic beam at any region of interest. The biological response of our standard HSG cell to various kinds and energy of ions is successfully reproduced by the MKM with measured specific energy for any particle species (9). Fig. 3 Current design of clinical SOBP at HIMAC\n-Production of secondary neutronsUnlike other charged fragment particles, secondary neutrons are largely scattered out in space. As a result, the secondary neutrons show wide spatial and energetic distributions. Absorbed dose delivered by the secondary neutrons is in average sparse; however, the neutron loses its energy in a matter by colliding with proton(s) and makes dense energy deposition in the vicinity of the collision point. The resultant local but high biological effectiveness is considered as one of the main causes of late effect after certain period of the C-ion RT. We have attempted to measure the dose delivered by neutrons to surrounding normal tissues in charged particle radiotherapy from the viewpoint of estimating the risk of their causing secondary cancer to the patient. A thick water phantom was irradiated with beams of 12C-290 MeV/n or 1H-160 MeV. Bonner sphere (6LiI(Eu) scintillator inserted) was placed around the phantom in order to measure the emitted neutrons. A commercial neutron rem counter was also used in the measurement for the sake of comparison. As an example, fig. 4 shows a comparison of ambient dose equivalent between the carbon and proton beam as an angle from beam axis by changing the aperture (MLC) size. The distribution of secondary neutrons is isotropic in the proton field while strong forward peak is observed in carbon field. The measurements suggest that the dose delivered by neutrons is less than 1 % of the total dose delivered by carbon ions. This dose level was found to be comparable to that obtained with protons (10).\nConclusion16 years have passed since the beginning of clinical trials for carbon therapy at HIMAC. Splendid clinical results derived for most cases would validate our first modeling of the therapeutic beam. To brush up the ongoing therapy modality and establish the optimal heavy-ion therapy in the next stage, both theoretical and experimental efforts must be paid further on the interactions of particles including neutrons with a matter and resultant biological effectiveness through the thorough understanding of the clinical outcomes.\n\nFig. 4 Ambient dose equivalent of secondary neutrons from carbon and proton beams.References Matsufuji N, Fukumura, A, Komori M et al. Influence of fragment reaction of relativistic heavy charged particles on heavy ion radiotherapy. Phys. Med. Biol. 2003: 48:1605-1623.Moliere G. Theorie der Streuung Schneller Geladener Teilchen. II. Mehrfach-und Vielfachstreuung Z. Naturforsch. 1948:3a:78&#8211;97.Matsufuji N, Komori M, Urakabe E et al. Spatial fragment distribution from a therapeutic pencil-like carbon beam in water. Phys. Med. Biol. 2005: 50: 3393-3403.Goldhaber A S. Statistical models of fragmentation processes. Phys. Lett. B: 1974: 53:306&#8211;308.Inaniwa T, Furukawa T, Matsufuji, N. et al. Clinical ion beams: semi-analytical calculation of their quality. Phys. Med. Biol. 2007: 52: 7261-7279.Kanai T, Endo M, Minohara S et al. Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy. Int. J. Radiat. Oncology Biol. Phys. 1999: 44: 201-210.Kanai T, Matsufuji N, Miyamoto T et al. Examination of GyE system for HIMAC carbon therapy. Int. J. Radiat. Oncology Biol. Phys. 2006: 64: 650-656.Hawkins R. B. A microdosimetric-kinetic model of cell death from exposure to ionizing radiation of any LET, with experimental and clinical applications. Int. J. Radiat. Biol. 1996: 69: 739-751.Kase Y, Kanai, T, Matsufuji, N et al. Biophysical calculation of cell survival probabilities using amorphous track structure models for heavy-ion irradiation. Phys. Med. Biol. 2008: 53: 37-59.Yonai S, Matsufuji N, Kanai T et al. Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies. Med. Phys. 2008: 35: 4782-4792.Joint Symposium: From Cancer Biology to Photon and Carbon Ion Radiation Therap

    Model evaluation of normal tissue response by mini-beam radiotherapy with ion beams

    No full text
    Bragg peak characteristics of ion beams makes ion-beam radiotherapy advantageous over conventional X-ray. The localized dose delivery to the Bragg peak enables to control deep-seated tumor cells while sparing surrounding benign tissues. The Bragg peak gets shaper for heavier ions; additionally, the biological effectiveness of carbon and its vicinity also increases gradually in accordance with increasing energy loss. Idea of the mini-beam radiation therapy (MBRT) was initially studied with X-ray as a method to spare proximal normal tissues by irradiating through submillimeter slit collimator. Recent studies try to apply the MBRT concept for proton beam by interlacing multiple sparse heterogeneous fields. The combination of the MBRT with ion-beam RT may lead further reduction of normal tissue toxicities.This study aims at assessing the efficacy of the MBRT with ion beams with commonly-used normal-tissue complication probability (NTCP) consideration.A Monte Carlo code PHITS was used to simulate the spatial dose distribution of carbon 276 MeV/n and proton 145 MeV pencil beams in water. Incident energy was selected to reach 15 cm depth. The beam was aligned in parallel at interval of the full width at half maximum at the Bragg peak layer. Accordingly, Equivalent Uniform Dose (EUD) widely used in common NTCP models was assessed from dose deposited proximal to the Bragg peak layer by changing the organ-structure parameter. The result revealed that carbon-ion beam is advantageous over protons in reducing EUD to the proximal normal tissues, however, the advantage of the mini-beam delivery was found only in case the normal tissue has extremely parallel-like structure therefore sensitive to minimum dose within the volume. The result is compared with the other NTCP models.World Congress on Medical Physics and Biomedical Engineering 2018 (IUPESM2018
    corecore