9 research outputs found
Advantages of radial volumetric breath-hold examination (VIBE) with k-space weighted image contrast reconstruction (KWIC) over Cartesian VIBE in liver imaging of volunteers simulating inadequate or no breath-holding ability
To investigate the superiority of radial volumetric breath-hold examination (r-VIBE) with k-space weighted image contrast reconstruction (KWIC) over Cartesian VIBE (c-VIBE) for reducing motion artefacts. We acquired r-VIBE-KWIC and c-VIBE images in 10 healthy volunteers. Each acquisition lasted 24 seconds. The volunteers held their breath for decreasing lengths of time during the acquisitions, from 24 to 0 seconds (protocols A-E). Magnetic resonance images at the level of the right portal vein and confluence of hepatic veins were assessed by two readers using a five-point scale with a higher number indicating a better study. The mean scores for the complete r-VIBE-KWIC series (r-VIBEfull) and first r-VIBE-KWIC series (r-VIBE1) were not significantly lower than those for c-VIBE in any protocols. The mean scores for c-VIBE were lower than those for r-VIBEfull and r-VIBE1 in protocols C and D. The mean score for c-VIBE was lower than that for r-VIBEfull in protocol E. The mean score for the eighth r-VIBE-KWIC series (r-VIBE8) was lower than that for c-VIBE only in protocol B. r-VIBE-KWIC minimised artefacts relative to c-VIBE at any slice location. The r-VIBE-KWIC's sub-frame images during the breath-holding period were hardly affected by another failed breath-holding period. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over c-VIBE aEuro cent The image quality of r-VIBE-KWIC's sub-frame images was maintained during breath holding aEuro cent Full-frame r-VIBE-KWIC images minimized motion artefacts caused by breathing aEuro cent A complete breath holding over half the acquisition time is recommended for c-VIBE aEuro cent c-VIBE was susceptible to respiratory motion especially in the subphrenic region.ArticleEUROPEAN RADIOLOGY.26(8):2790-2797(2016)journal articl
Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase
To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. aEuro cent Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. aEuro cent Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. aEuro cent Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. aEuro cent Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.ArticleEUROPEAN RADIOLOGY. 24(6):1290-1299 (2014)journal articl
Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase
To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. aEuro cent Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. aEuro cent Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. aEuro cent Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. aEuro cent Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.ArticleEUROPEAN RADIOLOGY. 24(6):1290-1299 (2014)journal articl
Effects of a Single Bolus Intravenous Dose of Tramadol on Minimum Alveolar Concentration (MAC) of Sevoflurane in Dogs
Tramadol is an atypical opioid analgesic widely used in small animal practice. This study was designed to determine the effect of a single intravenous (IV) dose of tramadol on the minimum alveolar concentration (MAC) of sevoflurane in dogs. Six beagle dogs were anesthetized twice to determine the sevoflurane MAC with or without an administration of tramadol (4mg/kg, IV) at 7 days interval. The sevoflurane MAC was determined using a tail clamp method in each dog ventilated with positive pressure ventilation. The tramadol administration produced a significant reduction in the sevoflurane MAC by 22.3±12.2% (1.44±0.28% with tramadol versus 1.86±0.30% without tramadol, P=0.010). This MAC reduction had been determined from 122±19 to 180±41 min following the tramadol administration. During this period, the plasma concentrations of tramadol and its metabolite, O-desmethyltramadol (M1), decreased from 429±64 to 332±55 ng/ml and from 136±24 to 114±68 ng/ml, respectively, but these changes were not statistically significant. There was no significant difference in heart rate, mean arterial blood pressure and SpO_2 between the control and tramadol treatment. The dogs that received tramadol treatment sometimes breathed spontaneously. Therefore, their respiratory rates significantly increased, and PETCO_2 decreased during the MAC determination. In conclusion, the single IV dose of tramadol produced a significant reduction in the sevoflurane MAC in dogs
Cardiovascular Effects of Tramadol in Dogs Anesthetized with Sevoflurane
Cardiovascular effects of tramadol were evaluated in dogs anesthetized with sevoflurane. Six beagle dogs were anesthetized twice at 7 days interval. The minimum alveolar concentration (MAC) of sevoflurane was earlier determined in each dog. The dogs were then anesthetized with sevoflurane at 1.3 times of predetermined individual MAC and cardiovascular parameters were evaluated before (baseline) and after an intravenous injection of tramadol (4 mg/kg). The administration of tramadol produced a transient and mild increase in arterial blood pressure (ABP) (P=0.004) with prolonged increase in systemic vascular resistance (SVR) (P<0.0001). Compared with baseline value, mean ABP increased significantly at 5 min (119% of baseline value, P=0.003), 10 min (113%, P=0.027), and 15 min (111%, P=0.022). SVR also increased significantly at 5 min (128%, P<0.0001), 10 min (121%, P=0.026), 30 min (114%, P=0.025), 45 min (113%, P=0.025) and 60 min (112%, P=0.048). Plasma concentrations of tramadol were weakly correlated with the percentage changes in mean ABP (r=0.642, P<0.0001) and SVR (r=0.646, P<0.0001). There was no significant change in heart rate, cardiac output, cardiac index, stroke volume, pulmonary arterial pressure, right atrial pressure and pulmonary capillary wedge pressure. In conclusion, the administration of tramadol produces a prolonged peripheral vascular constriction in dogs anesthetized with sevoflurane, which is accompanied with a transient and mild increase in arterial blood pressure. It also indicated that the degree of vasoconstriction might depend on the plasma concentration of tramadol