22 research outputs found

    Successful management of severe bupropion toxicity with lipid emulsion therapy: a complex case report and literature review

    Get PDF
    This case report presents the management of a 53-year-old female with a complex psychiatric history who ingested multiple medications, resulting in severe cardiovascular compromise and subsequent respiratory failure. The patient’s ingestion included clonidine, fluoxetine, gabapentin, quetiapine and bupropion. Initial treatment involved supportive measures, including fluid resuscitation, bicarbonate infusion and correction of electrolyte imbalances. Despite these interventions, the patient remained haemodynamically unstable, requiring multiple vasopressors. Lipid emulsion therapy was initiated and led to a remarkable improvement in the patient’s cardiovascular status. However, she developed acute respiratory distress syndrome (ARDS) and required prolonged mechanical ventilation. Steroid therapy was initiated to manage the ARDS, and the patient was successfully extubated on day 6. The case highlights the potential effectiveness of lipid emulsion therapy in managing bupropion toxicity, but emphasises the need for further research to establish clear guidelines on dosing, timing and safety protocols. Adverse effects associated with lipid emulsion therapy must be carefully considered. Individualised decision-making and patient-centred care is crucial in optimising outcomes in cases of bupropion toxicity

    Efficacy and safety of the new generation Watchman FLX device compared to the Watchman 2.5: a systematic review and meta-analysis.

    Get PDF
    The first-generation Watchman 2.5 (W 2.5) presented several limitations, such as challenges in implantation within complex left atrial appendage (LAA) anatomies, higher incidence of peri-device leak, device recapture, and device-related thrombus (DRT). The newer generation Watchman FLX (W-FLX) was introduced with a modified design aiming to overcome these limitations. The purpose of this meta-analysis is to conduct a comparative assessment of the safety and efficacy of the W-FLX and 2.5 devices in clinical practice. The meta-analysis was conducted according to the preferred reporting items for systematic review and meta-analysis protocols (PRISMA). Studies were located through a search strategy utilizing PubMed, Cochrane, Google scholar and MEDLINE from inception to March 2023, with a primary objective to compare the safety and efficacy of the W-FLX and W 2.5 devices. After applying the selection criteria, five studies were included in this analysis. The analysis included five studies comprising 54,727 patients. The W-FLX is associated with an increase in procedural success (OR 7.49 [95% CI 1.98-28.26, P = 0.02; = 0%]), and a significant reduction in mortality (OR 0.52 [95% CI 0.51-0.54, P<0.01; = 0%], major bleeding 0.57 [95% CI 0.51-0.64, P<0.01; = 0%]), device embolism (OR 0.35 [95% CI 0.18-0.70, P = 0.02; = 0%]), and pericardial effusion (OR 0.33 [95% CI 0.26-0.41, P<0.01; = 0%]). The rates of DRT and stroke were similar between the two groups. Compared to the W 2.5, the W-FLX was associated with a higher procedural success rate and significantly reduced adverse outcomes including mortality, major bleeding, device embolization, and pericardial effusion. [Abstract copyright: AJCD Copyright © 2023.

    Modélisation paramètrique 3-D fondée sur la décomposition de Wold (applications au filtrage de blocs sismiques 3-D)

    No full text
    Ce mémoire porte sur la modélisation de blocs 3D d'images texturées. L'objectif principal est de développer de nouveaux modèles paramétriques 3D qui permettent de caractériser une grande classe de textures. L'outil mathématique mis à contribution pour construire ces modèles est la décomposition de Wold des processus aléatoires discrets multidimentionnels. L'étude réalisée montre que tout bloc d'images texturées, considéré comme une réalisation d'un processus aléatoire homogène 3D, est la somme de quatre composantes orthogonales : une composante purement aléatoire, une composante harmonique et deux composantes évanescentes dites champ évanescent de type 1 et champ évanescent de type 2. Pour exploiter ce résultat théorique, nous proposons des modèles paramétriqaues adéquats pour approximer séparément les quatre composantes. a travers différentes études expérimentales, nous montrons que la modélisation fondée sur la décomposition de Wold 3D offre la possibilité de caractériser des blocs d'images présentant séparément ou à la fois les trois aspects fondamentaux des textures 3D : l'aspect aléatoire, l'aspect périodique et l'aspect directionnel. Les modèles proposés ont été utilisés pour le fitrage des blocs sismiques 2D fournis par le laboratoire commun "LASIS" CNRS-TOTAL. Dans ce contexte applicatif la décomposition de Wold 3D consiste, d'une part, à identifiier et à séparer les différents signaux qui composent la donnée sismique, et d'autre part, à distinguer parmi les composantes extraites celles qui représentent le signal sismique, après quoi le filtrage devient aisé.BORDEAUX1-BU Sciences-Talence (335222101) / SudocSudocFranceF

    Adding colchicine to tocilizumab in hospitalized patients with severe COVID-19 pneumonia: An open-label randomized controlled trial

    No full text
    INTRODUCTION: Colchicine acts upstream in the cytokines cascade by inhibiting the nod-like receptor protein 3 (NLRP3) inflammasome while interleukin 6 (IL-6) receptor antagonists, such as tocilizumab, block the end result of the cytokines cascade. Hence, adding colchicine to tocilizumab with the aim of blocking the early and end products of the cytokines cascade, might reduce the risk of developing cytokine storm. METHODS AND ANALYSIS: We aim to conduct an open-label randomized controlled trial to evaluate the efficacy and safety of adding colchicine to tocilizumab among patients with severe COVID-19 pneumonia to reduce the rate of invasive mechanical ventilation and mortality. We will include patients with severe COVID-19 pneumonia who received tocilizumab according to our local guidelines. Enrolled patients will be then randomized in 1:1 to colchicine versus no colchicine. Patients will be followed up for 30 days. The primary outcome is the rate of invasive mechanical ventilation and will be determined using Cox proportional hazard model. DISCUSSION: Given colchicine\u27s ease of use, low cost, good safety profile, and having different anti-inflammatory mechanism of action than other IL-6 blockade, colchicine might serve as a potential anti-inflammatory agent among patients with severe COVID-19 pneumonia. This study will provide valuable insights on the use of colchicine in severe COVID-19 when added to IL-6 antagonists. ETHICS AND DISSEMINATION: The Medical Research Center and Institutional Review Board at Hamad Medical Corporation in Qatar approved the study protocol (MRC-01-21-299). Results of the analysis will be submitted for publication in a peer-reviewed journal

    Syncope as the Sole Presentation of Multi-Vessel Coronary Artery Disease

    No full text
    Defining the etiology of syncope can be occasionally challenging. We present a case with no history of coronary artery disease (CAD) who presented exclusively with exertional syncope, and was found to have mildly reduced left ventricular systolic dysfunction on echocardiogram and severe multi-vessel CAD with chronic total occlusion (CTO) of the right coronary artery (RCA). Syncope as the initial presentation of advanced CAD in the absence of classic ischemic symptoms is rather an uncommon presentation in clinical practice

    Organizing pneumonia: An unusual sequela of COVID-19 infection

    No full text
    Organizing pneumonia (OP) is a form of interstitial lung disease that develops in response to acute lung injury. SARS-CoV-2 causes a wide range of lung and extrapulmonary disease, but there are few data suggesting an association between COVID-19 and OP. We describe a patient with COVID-19 pneumonia who developed severe progressive OP with significant morbidity. LEARNING POINTS: COVID-19 pneumonia is one of the secondary causes of organizing pneumonia (OP).Early initiation of steroids in OP is associated with improvement in symptoms and prognosis.A prolonged course of steroids may be needed in COVID-induced OP

    Efficacy and safety of the new generation Watchman FLX device compared to the Watchman 2.5: a systematic review and meta-analysis

    No full text
    Introduction: The first-generation Watchman 2.5 (W 2.5)TM presented several limitations, such as challenges in implantation within complex left atrial appendage (LAA) anatomies, higher incidence of peri-device leak, device recapture, and device-related thrombus (DRT). The newer generation Watchman FLX (W-FLX)TM was introduced with a modified design aiming to overcome these limitations. The purpose of this meta-analysis is to conduct a comparative assessment of the safety and efficacy of the W-FLX and 2.5 devices in clinical practice. Method: The meta-analysis was conducted according to the preferred reporting items for systematic review and meta-analysis protocols (PRISMA). Studies were located through a search strategy utilizing PubMed, Cochrane, Google scholar and MEDLINE from inception to March 2023, with a primary objective to compare the safety and efficacy of the W-FLX and W 2.5 devices. After applying the selection criteria, five studies were included in this analysis. Results: The analysis included five studies comprising 54,727 patients. The W-FLX is associated with an increase in procedural success (OR 7.49 [95% CI 1.98-28.26, P = 0.02; I2 = 0%]), and a significant reduction in mortality (OR 0.52 [95% CI 0.51-0.54, P\u3c 0.01; I2 = 0%], major bleeding 0.57 [95% CI 0.51-0.64, P\u3c 0.01; I2 = 0%]), device embolism (OR 0.35 [95% CI 0.18-0.70, P = 0.02; I2 = 0%]), and pericardial effusion (OR 0.33 [95% CI 0.26-0.41, P\u3c 0.01; I2 = 0%]). The rates of DRT and stroke were similar between the two groups. Conclusion: Compared to the W 2.5, the W-FLX was associated with a higher procedural success rate and significantly reduced adverse outcomes including mortality, major bleeding, device embolization, and pericardial effusion

    Meta-Analysis of the Outcomes of Peri-Device Leak After Left Atrial Appendage Closure

    No full text
    Left atrial appendage closure (LAAC) reduces the risk of thromboembolic stroke in atrial fibrillation. Peri-device leak (PDL) after LAAC may affect the subsequent risk of thromboembolism. We conducted a systematic review and meta-analysis to evaluate the effect of PDL after LAAC. We searched PubMed/Medline, Embase, and Google Scholar for studies reporting outcomes of PDL after LAAC from inception through October 2022. The primary outcome was the composite of stroke, transient ischemic attack (TIA), or systemic embolism (SE). Secondary outcomes included all-cause and cardiovascular mortality, ischemic stroke, TIA, and device-related thrombus. Outcomes were pooled using random-effects models. We used I2 statistics to assess statistical heterogeneity; I2 \u3e 50% considered significant heterogeneity. This study included 54,279 patients from 11 studies (6 observational, 2 nonrandomized controlled trials [non-RCTs] primary results, 2 RCT post hoc analyses, and 1 analysis combining 2 RCTs data). PDL was associated with a significant increase in the composite outcome of stroke, TIA, or SE (odds ratio 1.63, 95% confidence interval 1.06 to 2.52, p = 0.03, I2 = 43%) as compared with cases with no PDL. There were no significant differences in all-cause or cardiovascular mortality, ischemic stroke, TIA, or device-related thrombus. In conclusion, PDL after LAAC is associated with an increased risk of thromboembolism (composite stroke, TIA, or SE) without impacting mortality
    corecore