6 research outputs found

    Iliac branch endoprosthesis for repair of a common iliac artery aneurysm in Loeys-Dietz syndrome type 3

    No full text
    The commercial availability of the iliac branch endoprosthesis (IBE) has permitted endovascular repair of iliac artery aneurysms with the preservation of pelvic circulation. However, the device instructions for use require certain anatomic criteria that can limit deployment in ≤30% of patients. Moreover, branched endovascular treatment of common iliac artery aneurysms with IBE in patients with connective tissue disorders such as Loeys-Dietz syndrome has not been described. In the present report, we have described our technique of alternative endograft aortoiliac reconstruction to overcome anatomic barriers to IBE placement in a patient with a giant common iliac artery aneurysm in the setting of a rare pathogenic variant in the SMAD3 gene

    Trans-sternotomy, snare-assisted thoracic endovascular aortic repair for redirection of a migrated elephant trunk

    No full text
    The two-stage elephant trunk (ET) and thoracic endovascular aortic repair technique for type A and B aortic dissection can result in complications between the two stages. We have presented the case of a patient with an acute-on-chronic type B aortic dissection complicated by ET kinking and migration into the false lumen. We used a hybrid approach consisting of a first stage (retrograde thoracic endovascular aortic repair) and a second stage (“body floss” with antegrade thoracic endovascular aortic repair) to successfully reposition the ET back into the true lumen

    Direct stick embolization of a rectal venous malformation via transanal minimally invasive surgery

    No full text
    Rectal venous malformations (VMs) are rare clinical entities with variable patterns of presentation. Treatment requires unique, targeted strategies based on the symptoms, associated complications, and location, depth, and extent of the lesion. We present a rare case of a large, isolated rectal VM treated by direct stick embolization (DSE) using transanal minimally invasive surgery (TAMIS). A 49-year-old man had presented with a rectal mass incidentally detected on computed tomography urography. Magnetic resonance imaging and endoscopy revealed an isolated rectal VM. Elevated D-dimer levels concerning for localized intravascular coagulopathy warranted the use of prophylactic rivaroxaban. To avoid invasive surgery, DSE using TAMIS was performed successfully without complications. His postoperative recovery was uneventful, aside from a self-limiting and expected course of postembolization syndrome. To the best of our knowledge, this is the first reported case of TAMIS-assisted DSE of a colorectal VM. TAMIS shows promise for more widespread use in the minimally invasive, interventional management of colorectal vascular anomalies

    Aortic remodeling following hybrid arch repair with zone 0 to 5 thoracic endovascular aortic repairs for complex arch and descending thoracic aortic pathologiesCentral MessagePerspective

    No full text
    Objective: For high-risk patients with aortic arch pathology, hybrid aortic arch repair with simultaneous or staged thoracic endovascular repair of the descending aorta may be a viable alternative to open repair. However, data on postintervention aortic remodeling remain limited. We report the short-term outcomes of remodeling of the thoracoabdominal aorta after hybrid arch repair + thoracic endovascular repair. Methods: All patients undergoing hybrid arch repair with planned zones 0 to 5 thoracic endovascular repair from January 2020 to March 2022 were retrospectively reviewed. Computed tomography angiography scans preoperatively, after hybrid aortic arch repair, and on long-term follow-up were analyzed for thoracoabdominal aorta remodeling. Mean change in aortic true luminal diameter and full luminal diameter was calculated at every level, and paired-samples t test was used to compare means. Results: Of 39 patients, 38 had follow-up data at a mean duration of 14.9 months. There were a total of 3 (7.7%) deaths, 0 (0.0%) strokes, and 0 (0.0%) paralysis. For the 35 patients undergoing thoracic endovascular repair for aortic dissection, at follow-up, there was a significant increase in the mean true luminal diameter at each level (P < .05), except at the aortic bifurcation and common iliac arteries. The largest increase in mean true luminal diameter (P < .01) was observed at the level of the left inferior pulmonary vein (mean difference +13.22 mm, 95% CI, 10.38-16.07), tracheal carina (mean difference +13.06 mm, 95% CI, 10.05-16.07), and inferior left atrium (mean difference +11.19 mm, 95% CI, 7.84-14.53). Conclusions: Hybrid arch repair with zones 0 to 5 leads to improved true lumen augmentation in zones 0 to 8 with complete false lumen thrombosis down to zone 5 at short-term follow-up. Zones 9 to 11, if involved, may require adjunctive treatment strategies for total aortic remodeling and complete false lumen obliteration

    Superselective intranidal delivery of platinum-based high-density packing coils for treatment of arteriovenous malformations

    No full text
    Arteriovenous malformations (AVMs) classically feature an intervening nidus of poorly differentiated endothelium. The pillar of modern AVM treatment is intranidal delivery and deposition of various liquid embolic agents such as n-butyl cyanoacrylate, ethylene vinyl alcohol copolymer, and ethanol. These agents are cumbersome to prepare, deliver, and deploy and have been associated with complications related to limited delivery control, nonretrievability, frequent microcatheter exchanges, and nontarget embolization. Coils and other proximal occlusive agents have not been traditionally recommended as sole embolic agents for AVM treatment given the inherent lack of adequate AVM nidus penetration with previous coil technologies. In the present report, we have described a series of three patients with AVMs in whom newer generation, platinum-based, packing coils were used safely and effectively as the primary agent for superselective nidal penetration and embolization

    Emergent percutaneous chimney endovascular aortic repair of a secondary aortoenteric fistula in the setting of a solitary kidney

    No full text
    Secondary aortoenteric fistula is a potentially lethal complication after aortic surgery. Traditional treatment consists of open graft excision with extra-anatomic bypass or in situ reconstruction. Patients who present in extremis, however, are generally poor candidates for re-do open aortic surgery. Endovascular repair has emerged as an alternative treatment modality for patients who would otherwise be unable to tolerate an extended operation. We report here a case of urgent endovascular repair of a juxtarenal secondary aortoenteric fistula via endovascular aneurysm repair with a renal artery chimney in a patient with a solitary kidney who presented in hemorrhagic and septic shock
    corecore