101 research outputs found

    Nonstop Lose-Less Data Acquisition and Storing Method for Plasma Motion Images

    Get PDF
    Plasma diagnostic data analysis often requires the original raw data as they are, in other words, at the same frame rate and resolution of the CCD camera sensor. As a non-interlace VGA camera typically generates over 70 MB/s video stream, usual frame grabber cards apply the lossy compression encoder, such as mpeg-1/-2 or mpeg-4, to drastically lessen the bit rate. In this study, a new approach, which makes it possible to acquire and store such the wideband video stream without any quality reduction, has been successfully achieved. Simultaneously, the real-time video streaming is even possible at the original frame rate. For minimising the exclusive access time in every data storing, it has adopted the directory structure to hold every frame files separately, instead of one long consecutive file. The popular ‘zip’ archive method improves the portability of data files, however, the JPEG-LS image compression is applied inside by replacing its intrinsic deflate/inflate algorithm that has less performances for image data

    Adaptive data migration scheme with facilitator database and multi-tier distributed storage in LHD

    Get PDF
    Recent “data explosion” induces the demand for high flexibility of storage extension and data migration. The data amount of LHD plasma diagnostics has grown 4.6 times bigger than that of three years before. Frequent migration or replication between plenty of distributed storage becomes mandatory, and thus increases the human operational costs. To reduce them computationally, a new adaptive migration scheme has been developed on LHD’s multi-tier distributed storage. So-called the HSM (Hierarchical Storage Management) software usually adopts a low-level cache mechanism or simple watermarks for triggering the data stage-in and out between two storage devices. However, the new scheme can deal with a number of distributed storage by the facilitator database that manages the whole data locations with their access histories and retrieval priorities. Not only the inter-tier migration but also the intra-tier replication and moving are even manageable so that it can be a big help in extending or replacing storage equipment. The access history of each data object is also utilized to optimize the volume size of fast and costly RAID, in addition to a normal cache effect for frequently retrieved data. The new scheme has been verified its effectiveness so that LHD multi-tier distributed storage and other next-generation experiments can obtain such the flexible expandability

    VLBI Detections of Parsec-Scale Nonthermal Jets in Radio-Loud Broad Absorption Line Quasars

    Get PDF
    We conducted radio detection observations at 8.4 GHz for 22 radio-loud broad absorption line (BAL) quasars, selected from the Sloan Digital Sky Survey (SDSS) Third Data Release, by a very-long-baseline interferometry (VLBI) technique. The VLBI instrument we used was developed by the Optically ConnecTed Array for VLBI Exploration project (OCTAVE), which is operated as a subarray of the Japanese VLBI Network (JVN). We aimed at selecting BAL quasars with nonthermal jets suitable for measuring their orientation angles and ages by subsequent detailed VLBI imaging studies to evaluate two controversial issues of whether BAL quasars are viewed nearly edge-on, and of whether BAL quasars are in a short-lived evolutionary phase of quasar population. We detected 20 out of 22 sources using the OCTAVE baselines, implying brightness temperatures greater than 10^5 K, which presumably come from nonthermal jets. Hence, BAL outflows and nonthermal jets can be generated simultaneously in these central engines. We also found four inverted-spectrum sources, which are interpreted as Doppler-beamed, pole-on-viewed relativistic jet sources or young radio sources: single edge-on geometry cannot describe all BAL quasars. We discuss the implications of the OCTAVE observations for investigations for the orientation and evolutionary stage of BAL quasars.Comment: 10 pages, no figure, 3 tables, accepted for publication in PAS

    Broadband Multichannel Radiometer for ECE Measurements on KSTAR

    Get PDF
    A broadband heterodyne radiometer system has been developed and installed on KSTAR to measure second harmonic electron cyclotron emission (ECE) at the magnetic field of 3 T. The system consisting of two radiometers (110-162 GHz and 164-196 GHz) can cover a frequency range of 110-196 GHz. The unique and key components to construct this ECE diagnostic instrument are specially-designed detector modules and a diplexer for splitting ECE radiation with high efficiency. The minimum detectable electron temperature with a time response of 1 ?s is about 0.23 eV. The observed signal intensity is roughly consistent with the value estimated by using characteristics of various components (waveguide components, sub-harmonic mixers, amplifiers, and intermediate frequency detectors). In this article, design considerations and preliminary ECE measurements will be described

    Impurity emission characteristics of long pulse discharges in Large Helical Device

    Get PDF
    Line spectra from intrinsic impurity ions have been monitored during the three kinds of long-pulse discharges (ICH, ECH, NBI). Constant emission from the iron impurity shows no preferential accumulation of iron ion during the long-pulse operations. Stable Doppler ion temperature has been also measured from Fe XX, C V and C III spectra

    Stability and Confinement Studies of High-Performance NBI Plasmas in the Large Helical Device Toward a Steady-State Helical Fusion Reactor

    Get PDF
    Recent progress in plasma performance and the understanding of the related physics in the Large Helical Device is overviewed. The volume-averaged beta value is increased with an increase in the neutral beam injection (NBI) heating power, and it reached 5.0% of the reactor-relevant value. In high-β plasmas, the plasma aspect ratio should be controlled so that the Shafranov shift would be reduced, mainly to suppress transport degradation and the deterioration of the NBI heating efficiency. The operational regime of a high-density plasma with an internal diffusion barrier (IDB) has been extended, and the IDB, which was originally found using the local island divertor, has been realized in the helical divertor configuration. The central density was recorded as high as 1 × 1021 m-3, and the central pressure reached 130 kPa. Based on these high-density plasmas with the IDB, a new ignition scenario has been proposed. This should be a scenario specific to the helical fusion reactor, in which the helical ripple transport would be mitigated. A low-energy positive-NBI system was newly installed for an increase in the direct ion heating power. As a result, the ion temperature (Ti) exceeded 5.2 keV at a density of 1.2 × 1019 m-3 in a hydrogen plasma. Transport analysis shows improvement of ion transport, and the Ti-increase tends to be accompanied by a large toroidal rotation velocity of the order of 50 km/s in the core region. The plasma properties in the extended operational regime are discussed from the perspective of a steady-state helical fusion reactor

    Recent Results from LHD Experiment with Emphasis on Relation to Theory from Experimentalist’s View

    Get PDF
    he Large Helical Device (LHD) has been extending an operational regime of net-current free plasmas towardsthe fusion relevant condition with taking advantage of a net current-free heliotron concept and employing a superconducting coil system. Heating capability has exceeded 10 MW and the central ion and electron temperatureshave reached 7 and 10 keV, respectively. The maximum value of β and pulse length have been extended to 3.2% and 150 s, respectively. Many encouraging physical findings have been obtained. Topics from recent experiments, which should be emphasized from the aspect of theoretical approaches, are reviewed. Those are (1) Prominent features in the inward shifted configuration, i.e., mitigation of an ideal interchange mode in the configuration with magnetic hill, and confinement improvement due to suppression of both anomalous and neoclassical transport, (2) Demonstration ofbifurcation of radial electric field and associated formation of an internal transport barrier, and (3) Dynamics of magnetic islands and clarification of the role of separatrix
    • …
    corecore