6 research outputs found
Calculation of Stopping-Power Ratio from Multiple CT Numbers Using Photon-Counting CT System: Two- and Three-Parameter-Fitting Method
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μμA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise
Clinical efficacy of diquafosol sodium 3% versus hyaluronic acid 0.1% in patients with dry eye disease after cataract surgery: a protocol for a single-centre, randomised controlled trial.
INTRODUCTION: The number of cataract surgeries, the most common ophthalmic surgery, is expected to increase due to ageing populations. Dry eye disease (DED) is a frequent side effect of cataract surgery, contributing to lower postoperative patient satisfaction and suboptimal quality of vision. It is unclear which eye-drops commonly used in these patients should be recommended for postoperative DED treatment. This study aims to compare the efficacy of topical administration of diquafosol sodium 3% vs hyaluronic acid 0.1% eye-drops in patients with DED after cataract surgery.
METHODS AND ANALYSIS: The study is designed as a single-blind randomised controlled trial. The participants will be randomly (1:1) allocated to either the diquafosol sodium 3% topical administration group (n=21) or the hyaluronic acid 0.1% topical administration group (n=21). Each group will receive its assigned eye-drop intervention over a 12-week period. The primary outcome will be measured using the total score of the Japanese version of the Ocular Surface Disease Index during the visit 5 weeks postoperatively. Both groups will be followed up after their respective eye-drop application for 12 weeks according to the intervention regimens. Secondary outcome measures including meibomian gland function assessment, tear film break-up time, keratoconjunctival staining score, maximum blink interval and tear secretion volume using Schirmer\u27s test I will be assessed at 1, 5, 9, 13 and 25 weeks postoperatively.
ETHICS AND DISSEMINATION: This study has been approved by the Juntendo Hospital Certified Review Board, Tokyo, Japan (Approved protocol V.7.0 dated 7 May 2021. Approval number: J20-018) and has been registered with the Japan Registry of Clinical Trials. Written informed consent will be collected from every patient prior to study participation. The results of this trial will be presented at local and international meetings and submitted to peer-reviewed journals for publication.
TRIAL REGISTRATION NUMBER: jRCT1031210018
Biological effects of stored platelet-rich plasma eye-drops in corneal wound healing.
BACKGROUND/AIMS: This study aimed to assess the efficacy and sterility of stored platelet-rich plasma (PRP) eye-drops for corneal epithelial wound healing compared with those of autologous serum (AS) eye-drops.
METHODS: At our single institution, PRP and AS eye-drops were prepared using peripheral blood obtained from six healthy volunteers and stored at 4°C. Platelet and leucocyte counts and transforming growth factor (TGF)-β1, epidermal growth factor (EGF), and fibronectin levels were assessed during storage for up to 4 weeks. Sterility was assessed by culturing 4-week poststorage samples. PRP, AS, and phosphate-buffered saline (PBS) eye-drop efficacies were compared using corneal epithelial wound healing assays
RESULTS: Higher platelet and lower leucocyte counts were seen in PRP than in whole blood on the day of preparation. After storage, TGF-β1, EGF, and fibronectin levels were significantly higher in PRP than in AS eye-drops.
CONCLUSION: PRP eye-drops stored at 4°C for 4 weeks promoted corneal epithelial wound healing with higher levels of growth factors than those observed in AS eye-drops, while maintaining sterility, suggesting that this preparation satisfies the unmet medical needs in the treatment of refractory keratoconjunctival epithelial disorders
Using the AllerSearch Smartphone App to Assess the Association Between Dry Eye and Hay Fever: mHealth-Based Cross-Sectional Study
BackgroundDry eye (DE) and hay fever (HF) show synergistic exacerbation of each other’s pathology through inflammatory pathways.
ObjectiveThis study aimed to investigate the association between DE and HF comorbidity and the related risk factors.
MethodsA cross-sectional observational study was conducted using crowdsourced multidimensional data from individuals who downloaded the AllerSearch smartphone app in Japan between February 2018 and May 2020. AllerSearch collected the demographics, medical history, lifestyle and residential information, HF status, DE symptoms, and HF-related quality of life. HF symptoms were evaluated using the nasal symptom score (0-15 points) and nonnasal symptom score (0-12 points). HF was defined by the participants’ responses to the questionnaire as HF, non-HF, or unknown. Symptomatic DE was defined as an Ocular Surface Disease Index total score (0-100 points), with a threshold score of 13 points. HF-related quality of life was assessed using the Japanese Allergic Conjunctival Disease Standard Quality of Life Questionnaire (0-68 points). We conducted a multivariable linear regression analysis to examine the association between the severity of DE and HF symptoms. We subsequently conducted a multivariable logistic regression analysis to identify the factors associated with symptomatic DE (vs nonsymptomatic DE) among individuals with HF. Dimension reduction via Uniform Manifold Approximation and Projection stratified the comorbid DE and HF symptoms. The symptom profiles in each cluster were identified using hierarchical heat maps.
ResultsThis study included 11,284 participants, classified into experiencing HF (9041 participants), non-HF (720 participants), and unknown (1523 participants) groups. The prevalence of symptomatic DE among individuals with HF was 49.99% (4429/9041). Severe DE symptoms were significantly associated with severe HF symptoms: coefficient 1.33 (95% CI 1.10-1.57; P<.001) for mild DE, coefficient 2.16 (95% CI 1.84-2.48; P<.001) for moderate DE, and coefficient 3.80 (95% CI 3.50-4.11; P<.001) for severe DE. The risk factors for comorbid symptomatic DE among individuals with HF were identified as female sex; lower BMI; medicated hypertension; history of hematologic, collagen, heart, liver, respiratory, or atopic disease; tomato allergy; current and previous mental illness; pet ownership; living room and bedrooms furnished with materials other than hardwood, carpet, tatami, and vinyl; discontinuation of contact lens use during the HF season; current contact lens use; smoking habits; and sleep duration of <6 hours per day. Uniform Manifold Approximation and Projection stratified the heterogeneous comorbid DE and HF symptoms into 14 clusters. In the hierarchical heat map, cluster 9 was comorbid with the most severe HF and DE symptoms, and cluster 1 showed severe HF symptoms with minimal DE-related symptoms.
ConclusionsThis crowdsourced study suggested a significant association between severe DE and HF symptoms. Detecting DE among individuals with HF could allow effective prevention and interventions through concurrent treatment for ocular surface management along with HF treatment
Diagnostic Ability of a Smartphone App for Dry Eye Disease: Protocol for a Multicenter, Open-Label, Prospective, and Cross-sectional Study.
BACKGROUND: Dry eye disease (DED) is one of the most common ocular surface diseases. Numerous patients with DED remain undiagnosed and inadequately treated, experiencing various subjective symptoms and a decrease in quality of life and work productivity. A mobile health smartphone app, namely, the DEA01, has been developed as a noninvasive, noncontact, and remote screening device, in the context of an ongoing paradigm shift in the health care system, to facilitate a diagnosis of DED.
OBJECTIVE: This study aimed to evaluate the capabilities of the DEA01 smartphone app to facilitate a DED diagnosis.
METHODS: In this multicenter, open-label, prospective, and cross-sectional study, the test method will involve using the DEA01 smartphone app to collect and evaluate DED symptoms, based on the Japanese version of the Ocular Surface Disease Index (J-OSDI), and to measure the maximum blink interval (MBI). The standard method will then involve a paper-based J-OSDI evaluation of subjective symptoms of DED and tear film breakup time (TFBUT) measurement in an in-person encounter. We will allocate 220 patients to DED and non-DED groups, based on the standard method. The primary outcome will be the sensitivity and specificity of the DED diagnosis according to the test method. Secondary outcomes will be the validity and reliability of the test method. The concordance rate, positive and negative predictive values, and the likelihood ratio between the test and standard methods will be assessed. The area under the curve of the test method will be evaluated using a receiver operating characteristic curve. The internal consistency of the app-based J-OSDI and the correlation between the app-based J-OSDI and paper-based J-OSDI will be assessed. A DED diagnosis cutoff value for the app-based MBI will be determined using a receiver operating characteristic curve. The app-based MBI will be assessed to determine a correlation between a slit lamp-based MBI and TFBUT. Adverse events and DEA01 failure data will be collected. Operability and usability will be assessed using a 5-point Likert scale questionnaire.
RESULTS: Patient enrollment will start in February 2023 and end in July 2023. The findings will be analyzed in August 2023, and the results will be reported from March 2024 onward.
CONCLUSIONS: This study may have implications in identifying a noninvasive, noncontact route to facilitate a diagnosis of DED. The DEA01 may enable a comprehensive diagnostic evaluation within a telemedicine setting and facilitate early intervention for undiagnosed patients with DED confronting health care access barriers.
TRIAL REGISTRATION: Japan Registry of Clinical Trials jRCTs032220524; https://jrct.niph.go.jp/latest-detail/jRCTs032220524.
INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/45218