115 research outputs found

    Native T1 high region and left ventricular ejection fraction recovery in patients with dilated cardiomyopathy

    Get PDF
    Native T1 mapping is used to assess myocardial tissue characteristics without gadolinium contrast agents. The focal T1 high-intensity region can indicate myocardial alterations. This study aimed to identify the association between the native T1 mapping including the native T1 high region and left ventricular ejection fraction (LVEF) recovery in patients with dilated cardiomyopathy (DCM). Patients with newly diagnosed DCM (LVEF of 5 SD in the remote myocardium. Recovered EF was defined as a follow-up LVEF of >= 45% and an LVEF increase of >= 10% after 2 years from baseline. Seventy-one patients met the inclusion criteria for this study. Forty-four patients (61.9%) achieved recovered EF. Logistic regression analysis showed that the native T1 value (OR: 0.98; 95% CI: 0.96-0.99; P = 0.014) and the native T1 high region (OR: 0.17; 95% CI: 0.05-0.55; P = 0.002), but not late gadolinium enhancement, were independent predictors of recovered EF. Compared with native T1 value alone, combined native T1 high region and native T1 value improved the area under the curve from 0.703 to 0.788 for predicting recovered EF. Myocardial damage, which was quantified using native T1 mapping and the native T1 high region were independently associated with recovered EF in patients with newly diagnosed DCM.Cardiolog

    Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda

    Get PDF
    BACKGROUND: Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings. METHODS: We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primostar™ iLED, Lumin™ and AFTER®) for fluorescent detection of Mycobacterium tuberculosis with ZN microscopy on slides prepared from sputum of TB suspects. Examination time for LED-based fluorescent microscopy (LED FM) and ZN slides was also compared, and a qualitative user appraisal of the LED FM systems was carried out. RESULTS: LED FM was between 5.6 and 9.4% more sensitive than ZN microscopy, although the difference was not statistically significant. There was no significant difference in the sensitivity or specificity of the three LED FM systems, although the specificity of Fraen AFTER was somewhat lower than the other LED FM methods. Examination time for LED FM was 2 and 4 times less than for ZN microscopy. LED FM was highly acceptable to Ugandan technologists, although differences in operational performance of the three systems were reported. CONCLUSIONS: LED FM compares favourably with ZN microscopy, with equivalent specificity and a modest increase in sensitivity. Screening of slides was substantially quicker using LED FM than ZN, and LED FM was rated highly by laboratory technologists. Available commercial systems have different operational characteristics which should be considered prior to programmatic implementation

    Sleep-effects on implicit and explicit memory in repeated visual search

    Get PDF
    In repeated visual search tasks, facilitation of reaction times (RTs) due to repetition of the spatial arrangement of items occurs independently of RT facilitation due to improvements in general task performance. Whereas the latter represents typical procedural learning, the former is a kind of implicit memory that depends on the medial temporal lobe (MTL) memory system and is impaired in patients with amnesia. A third type of memory that develops during visual search is the observers’ explicit knowledge of repeated displays. Here, we used a visual search task to investigate whether procedural memory, implicit contextual cueing, and explicit knowledge of repeated configurations, which all arise independently from the same set of stimuli, are influenced by sleep. Observers participated in two experimental sessions, separated by either a nap or a controlled rest period. In each of the two sessions, they performed a visual search task in combination with an explicit recognition task. We found that (1) across sessions, MTL-independent procedural learning was more pronounced for the nap than rest group. This confirms earlier findings, albeit from different motor and perceptual tasks, showing that procedural memory can benefit from sleep. (2) Likewise, the sleep group compared with the rest group showed enhanced context-dependent configural learning in the second session. This is a novel finding, indicating that the MTL-dependent, implicit memory underlying contextual cueing is also sleep-dependent. (3) By contrast, sleep and wake groups displayed equivalent improvements in explicit recognition memory in the second session. Overall, the current study shows that sleep affects MTL-dependent as well as MTL-independent memory, but it affects different, albeit simultaneously acquired, forms of MTL-dependent memory differentially

    Diagnostic accuracy of a three-gene Mycobacterium tuberculosis host response cartridge using fingerstick blood for childhood tuberculosis: a multicentre prospective study in low-income and middle-income countries

    Get PDF
    BACKGROUND: Childhood tuberculosis remains a major cause of morbidity and mortality in part due to missed diagnosis. Diagnostic methods with enhanced sensitivity using easy-to-obtain specimens are needed. We aimed to assess the diagnostic accuracy of the Cepheid Mycobacterium tuberculosis Host Response prototype cartridge (MTB-HR), a candidate test measuring a three-gene transcriptomic signature from fingerstick blood, in children with presumptive tuberculosis disease. METHODS: RaPaed-TB was a prospective diagnostic accuracy study conducted at four sites in African countries (Malawi, Mozambique, South Africa, and Tanzania) and one site in India. Children younger than 15 years with presumptive pulmonary or extrapulmonary tuberculosis were enrolled between Jan 21, 2019, and June 30, 2021. MTB-HR was performed at baseline and at 1 month in all children and was repeated at 3 months and 6 months in children on tuberculosis treatment. Accuracy was compared with tuberculosis status based on standardised microbiological, radiological, and clinical data. FINDINGS: 5313 potentially eligible children were screened, of whom 975 were eligible. 784 children had MTB-HR test results, of whom 639 had a diagnostic classification and were included in the analysis. MTB-HR differentiated children with culture-confirmed tuberculosis from those with unlikely tuberculosis with a sensitivity of 59·8% (95% CI 50·8–68·4). Using any microbiological confirmation (culture, Xpert MTB/RIF Ultra, or both), sensitivity was 41·6% (34·7–48·7), and using a composite clinical reference standard, sensitivity was 29·6% (25·4–34·2). Specificity for all three reference standards was 90·3% (95% CI 85·5–94·0). Performance was similar in different age groups and by malnutrition status. Among children living with HIV, accuracy against the strict reference standard tended to be lower (sensitivity 50·0%, 15·7–84·3) compared with those without HIV (61·0%, 51·6–69·9), although the difference did not reach statistical significance. Combining baseline MTB-HR result with one Ultra result identified 71·2% of children with microbiologically confirmed tuberculosis. INTERPRETATION: MTB-HR showed promising diagnostic accuracy for culture-confirmed tuberculosis in this large, geographically diverse, paediatric cohort and hard-to-diagnose subgroups. FUNDING: European and Developing Countries Clinical Trials Partnership, UK Medical Research Council, Swedish International Development Cooperation Agency, Bundesministerium für Bildung und Forschung; German Center for Infection Research (DZIF)

    Rapid and Accurate Diagnosis of Pediatric Tuberculosis Disease (RaPaed-TB): A Diagnostic Accuracy Study for Pediatric Tuberculosis.

    Get PDF
    Introduction: An estimated 1.2 million children develop tuberculosis (TB) every year with 240,000 dying because of missed diagnosis. Existing tools suffer from lack of accuracy and are often unavailable. Here, we describe the scientific and clinical methodology applied in RaPaed-TB, a diagnostic accuracy study. Methods: This prospective diagnostic accuracy study evaluating several candidate tests for TB was set out to recruit 1000 children <15 years with presumptive TB in 5 countries (Malawi, Mozambique, South Africa, Tanzania, India). Assessments at baseline included documentation of TB signs and symptoms, TB history, radiography, tuberculin skin test, HIV testing and spirometry. Respiratory samples for reference standard testing (culture, Xpert Ultra) included sputum (induced/spontaneous) or gastric aspirate, and nasopharyngeal aspirate (if <5 years). For novel tests, blood, urine and stool were collected. All participants were followed up at months 1 and 3, and month 6 if on TB treatment or unwell. The primary endpoint followed NIH-consensus statements on categorization of TB disease status for each participant. The study was approved by the sponsor's and all relevant local ethics committees. As a diagnostic accuracy study for a disease with an imperfect reference standard, RaPaed-TB was designed following a rigorous and complex methodology. This allows for the determination of diagnostic accuracy of novel assays and combination of testing strategies for optimal care for children, including high-risk groups (ie, very young, malnourished, children living with HIV). Being one of the largest of its kind, RaPaed-TB will inform the development of improved diagnostic approaches to increase case detection in pediatric TB

    Analysis on descriptions of precautionary statements in package inserts of medicines

    Full text link
    Keita Nabeta1, Masaomi Kimura2, Michiko Ohkura2, Fumito Tsuchiya31Graduate School of Engineering and Science, Shibaura Institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo, 135-8548 Japan; 2Faculty of Engineering, Shibaura Institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo, 135-8548 Japan; 3School of Pharmacy, International University of Health and Welfare, Minami-Aoyama 1-24-1, Minato-ku, Tokyo, 107-0062 JapanBackground: To prevent medical accidents, users must be informed of the cautions written in medical package inserts. To realize countermeasures by utilizing information systems, we must also implement a drug information database. However, this is not easy to develop, since the descriptions in package inserts are too complex and their information poorly structured. It is necessary to analyze package insert information and propose a data structure.Methods: We analyzed the descriptions of &amp;#39;precautions for application&amp;#39; in package inserts via text mining methods. In order to summarize statements, we applied dependency analysis to statements and visualized their relations between predicate words and other words. Furthermore, we extracted words representing timing to execute the order.Results: We found that there are four types of statements: direct orders such as &amp;quot;使用する&amp;quot; (use), causative orders such as &amp;quot;使用させる&amp;quot; (make someone use), direct interdictions such as &amp;quot;使用しない&amp;quot; (do not use), and causative interdictions such as &amp;quot;使用させない&amp;quot; (do not make user use). As for words representing timing, we extracted six groups: &amp;quot;at the time of delivery,&amp;quot; &amp;quot;at the time of preparation,&amp;quot; &amp;quot;in use,&amp;quot; &amp;quot;after use,&amp;quot; and &amp;quot;at the time of storage.&amp;quot; From these results, we obtained points of consideration concerning the subjects of orders in the statements and timing of their execution.Conclusion: From the obtained knowledge, we can define the information structure used to describe the precautionary statement. It should contain information such as the actions described in the statement, the flag to express an order or interdiction, the subject to be ordered, and the timing.Keywords: medical safety, drug information, package insert, drug database, text minin
    corecore