16 research outputs found

    Non-ionic Thermoresponsive Polymers in Water

    Full text link

    Clinical and virological features of acute HBV-related hepatitis in southern vietnam

    No full text
    Background: Despite the availability of effective vaccines, hepatitis B virus (HBV) infection is still frequent worldwide, and accounts for significant morbidity and mortality. However, data of acute HBeAg negative hepatitis still remain limited. Aims and Methods: To understand clinical pictures of acute HBV hepatitis and its natural evolution, a prospective study was conducted in adult patients. Results: Ninety patients were enrolled between March 2004 and April 2005 at Hospital for Tropical Diseases in Ho Chi Minh city. The prevalence of HBeAg negative was 53%. No significant difference was found in clinical characteristics and laboratory findings between HBeAg positive and negative patients. HBV-DNA was detected in 75% and 88% HBe negative and positive patients, respectively, where the frequency of ALT below 400 U/L was significantly higher in HBeAg negative cases (p = 0.01). Six month follow-up was available in 47 patients. HBsAg positivity was found in 16% of HBeAg negative subjects but only in 4.5% of HBeAg positive cases. Thirty two patients had neither HBsAg nor anti-HBs. Conclusions: The clinical and laboratory feature and the outcome at 6 months of HBV acute hepatitis in Vietnam is similar in HBeAg positive and negative patients

    Evaluation of the Luminex xTAG Respiratory Viral Panel FAST v2 assay for detection of multiple respiratory viral pathogens in nasal and throat swabs in Vietnam [version 1; referees: 2 approved]

    No full text
    Background: Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays for ARI in Vietnam. Methods: Four hundred and forty two nose and throat swabs were collected in viral transport medium, and were tested with Luminex xTAG Respiratory Viral Panel FAST v2. Multiplex RT-PCR and single RT-PCR were used as references. Results: Overall, viral pathogens were detected in a total count of 270/294 (91.8%, 95% CI 88.1-94.7) by the Luminex among reference assays, whilst 112/6336 (1.8%, 95% CI, 1.4-2.1) of pathogens were detected by the Luminex, but not by reference assays. Frequency of pathogens detected by Luminex and reference assays was 379 and 292, respectively. The diagnostic yield was 66.7% (295/442, 95%CI 62.1-71.1%) for the Luminex assay and 54.1% (239/442, 95% CI, 49.3-58.8%) for reference assays. The Luminex kit had higher yields for all viruses except influenza B virus, respiratory syncytial virus, and human bocavirus. High agreements between both methods [mean (range): 0.91 (0.83-1.00)] were found for 10/15 viral agents. Conclusions: The Luminex assay is a high throughput multiplex platform for rapid detection of common viral pathogens causing ARI. Although the current high cost may prevent Luminex assays from being widely used, especially in limited resource settings where ARI are felt most, its introduction in clinical diagnostics may help reduce unnecessary use of antibiotic prescription
    corecore