206 research outputs found

    Determining the chemical exchange saturation transfer (CEST) behavior of citrate and spermine under in vivo conditions.

    Get PDF
    Purpose To estimate the exchange rates of labile (1) H in citrate and spermine, metabolites present in prostatic secretions, to predict the size of the citrate and spermine CEST effects in vivo.Methods CEST z-spectra were acquired at high-field [11.7 Tesla (T)] from citrate and spermine solutions at physiological pH (6.5) using saturation power 6 μT. CEST was performed at different temperatures to determine exchange regimes (slow, intermediate or fast). For low pH solutions of spermine, exchange rates were estimated from resonance line width, fitting z-spectra using the Bloch equations incorporating exchange, and using quantifying exchange using saturation time experiments (QUEST). These rates were extrapolated to physiological pH.Results Citrate showed little CEST effect at pH 6.5 and temperature (T) = 310 K (maximum 0.001% mM(-1) ), indicating fast exchange, whereas spermine showed greater CEST effects (maximum 0.2% mM(-1) ) indicating intermediate-to-fast exchange. Extrapolating data acquired from low pH spermine solutions predicts exchange rates at pH 6.5 and T of 310 K of at least 2 × 10(4) s(-1) .Conclusion Citrate and spermine show minimal CEST effects at 11.7T even using high saturation power. These effects would be much less than 2% at clinical field-strengths due to relatively faster exchange and would be masked by CEST from proteins. Magn Reson Med 76:742-746, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited

    The effect of FASN inhibition on the growth and metabolism of a cisplatin-resistant ovarian carcinoma model.

    Get PDF
    Overexpression of fatty acid synthase (FASN), a key regulator of the de novo synthesis of fatty acids, has been demonstrated in a variety of cancers and is associated with poor prognosis and increased multidrug resistance. Inhibition of FASN with the anti-obesity drug orlistat has been shown to have significant anti-tumourigenic effects in many cancers, notably breast and prostate. In our study, we investigated whether FASN inhibition using orlistat is an effective adjunctive treatment for ovarian cancers that have become platinum resistant using a cisplatin-resistant ovarian tumour xenograft model in mice. Mice were treated with orlistat or cisplatin or a combination and metabolite analysis and histopathology were performed on the tumours ex vivo. Orlistat decreased tumour fatty acid metabolism by inhibiting FASN, cisplatin reduced fatty acid β-oxidation, and combination treatment delayed tumour growth and induced apoptotic and necrotic cell death in cisplatin-resistant ovarian cancer cells over and above that with either treatment alone. Combination treatment also decreased glutamine metabolism, nucleotide and glutathione biosynthesis and fatty acid β-oxidation. Our data suggest that orlistat chemosensitised platinum-resistant ovarian cancer to treatment with platinum and resulted in enhanced efficacy

    A framework for optimization of diffusion-weighted MRI protocols for large field-of-view abdominal-pelvic imaging in multicenter studies.

    Get PDF
    PURPOSE: To develop methods for optimization of diffusion-weighted MRI (DW-MRI) in the abdomen and pelvis on 1.5 T MR scanners from three manufacturers and assess repeatability of apparent diffusion coefficient (ADC) estimates in a temperature-controlled phantom and abdominal and pelvic organs in healthy volunteers. METHODS: Geometric distortion, ghosting, fat suppression, and repeatability and homogeneity of ADC estimates were assessed using phantoms and volunteers. Healthy volunteers (ten per scanner) were each scanned twice on the same scanner. One volunteer traveled to all three institutions in order to provide images for qualitative comparison. The common volunteer was excluded from quantitative analysis of the data from scanners 2 and 3 in order to ensure statistical independence, giving n = 10 on scanner 1 and n = 9 on scanners 2 and 3 for quantitative analysis. Repeatability and interscanner variation of ADC estimates in kidneys, liver, spleen, and uterus were assessed using within-patient coefficient of variation (wCV) and Kruskal-Wallis tests, respectively. RESULTS: The coefficient of variation of ADC estimates in the temperature-controlled phantom was 1%-4% for all scanners. Images of healthy volunteers from all scanners showed homogeneous fat suppression and no marked ghosting or geometric distortion. The wCV of ADC estimates was 2%-4% for kidneys, 3%-7% for liver, 6%-9% for spleen, and 7%-10% for uterus. ADC estimates in kidneys, spleen, and uterus showed no significant difference between scanners but a significant difference was observed in liver (p < 0.05). CONCLUSIONS: DW-MRI protocols can be optimized using simple phantom measurements to produce good quality images in the abdomen and pelvis at 1.5 T with repeatable quantitative measurements in a multicenter study

    The Influence of Fat Suppression Technique on Diffusion-weighted (DW) MRI in Lung Cancer

    Get PDF
    Purpose: To qualitatively and quantitatively investigate the effect of common vendor-related sequence variations in fat suppression techniques on the diagnostic performance of free-breathing DW protocols for lung imaging.Methods: 8 patients with malignant lung lesions were scanned in free breathing using two diffusion-weighted (DW) protocols with different fat suppression techniques: DWA used short-tau inversion recovery (STIR), and DWB used Spectral Adiabatic Inversion Recovery (SPAIR). Both techniques were obtained at two time points, between 1 hour and 1 week apart. Image quality was assessed using a 5-point scoring system. The number of lesions visible within lung, mediastinum and at thoracic inlet on the DW (b=800 s/mm2) images was compared. Signal-to-noise ratios (SNR) were calculated for lesions and para-spinal muscle. Repeatability of ADC values of the lesions was estimated for both protocols together and separately.Results: There was a signal void at the thoracic inlet in all patients with DWB but not with DWA. DWA images were rated significantly better than DWB images overall quality domains. (Cohens κ = 1). Although 8 more upper mediastinal/thoracic inlet lymph nodes were detected with DWA than DWB, this did not reach statistical significance (p = 0.23). Tumour ADC values were not significantly different between protocols (p=0.93), their ADC reproducibility was satisfactory (CoV=7.7%) and repeatability of each protocol separately was comparable (CoVDWA=3.7% (95% CI 2.5 7.1%) and CoVDWB=4.6% (95% CI 3.18.8%)).Conclusion: In a free-breathing DW-MRI protocol for lung, STIR fat suppression produced images of better diagnostic quality than SPAIR, while maintaining comparable SNR and providing repeatable quantitative ADC acceptable for use in a multicentre trial setting

    MR guided high intensity focused ultrasound (MRgHIFU) for treating recurrent gynaecological tumours: a pilot feasibility study.

    Get PDF
    Objective To assess the feasibility of targeting recurrent gynaecological tumours with MR guided high intensity focused ultrasound (MRgHIFU).Methods 20 patients with recurrent gynaecological tumours were prospectively scanned on a Philips/Profound 3 T Achieva MR/ Sonalleve HIFU system. Gross tumour volume (GTV) and planning target volume (PTV) were delineated on T 2W and diffusion-weighted imaging (DWI). Achievable treatment volumes that (i) assumed bowel and/or urogenital tract preparation could be used to reduce risk of damage to organs-at-risk (TVoptimal), or (ii) assumed no preparations were possible (TVno-prep) were compared with PTV on virtual treatment plans. Patients were considered treatable if TVoptimal ≥ 50 % PTV.Results 11/20 patients (55%) were treatable if preparation strategies were used: nine had central pelvic recurrences, two had tumours in metastatic locations. Treatable volume ranged from 3.4 to 90.3 ml, representing 70 ± 17 % of PTVs. Without preparation, 6/20 (30%) patients were treatable (four central recurrences, two metastatic lesions). Limiting factors were disease beyond reach of the HIFU transducer, and bone obstructing tumour access. DWI assisted tumour outlining, but differences from T 2W imaging in GTV size (16.9 ± 23.0%) and PTV location (3.8 ± 2.8 mm in phase-encode direction) limited its use for treatment planning.Conclusions Despite variation in size and location within the pelvis, ≥ 50 % of tumour volumes were considered targetable in 55 % patients while avoiding adjacent critical structures. A prospective treatment study will assess safety and symptom relief in a second patient cohort.Advances in knowledge Target size, location and access make MRgHIFU a viable treatment modality for treating symptomatic recurrent gynaecological tumours within the pelvis
    • …
    corecore