80 research outputs found

    A novel atrial volume reduction technique to enhance the Cox maze procedure: Initial results

    Get PDF
    ObjectiveLarge left atrial diameter is reported to be a predictor for recurrent atrial fibrillation after the Cox maze procedure, and left atrial diameter by itself influences the chance of sinus rhythm recovery, as well as maintenance of sinus rhythm. However, additional cut-and-sew procedures to decrease left atrial diameter extend operative time and can cause bleeding. Thus we developed a no-bleeding, faster, and therefore less invasive left atrial volume reduction technique to enhance the Cox maze procedure.MethodsThe modified Cox maze III procedure with cryoablation or the left atrial maze procedure in association with mitral valve surgery was performed in 80 patients with atrial fibrillation and enlarged left atria (≥60 mm). Among them, 44 patients had the concomitant volume reduction technique (VR group); continuous horizontal mattress sutures for left atrial plication were placed on the left atrial wall along the pulmonary vein isolation line. Cryoablation was applied to the suture line so that the plicated left atrium is anatomically and electrically isolated. Another 36 patients did not have the volume reduction technique (control group).ResultsThe VR group had preoperative left atrial diameters similar to those of the control group (67.1 ± 7.8 vs 64.5 ± 6.7 mm) and a longer preoperative duration of atrial fibrillation (14.1 ± 5.4 vs 9.5 ± 5.1 years, P < .05) but had smaller postoperative left atrial diameters (47.6 ± 6.3 vs 62.1 ± 7.9 mm, P < .01). There were no differences in mean crossclamp/bypass time and chest tube drainage for 12 hours between the groups. Twelve months after surgical intervention, the sinus rhythm recovery rate of the VR group was better than that of the control group (90% vs 69%, P < .05).ConclusionsEven in patients with long-standing atrial fibrillation and an enlarged left atrium, maze procedures concomitant with the novel left atrial volume reduction technique improved the sinus rhythm recovery rate without increasing complications. Although further study with a larger number of patients and a longer follow-up period is needed, this safe and thus far potent technique that catheter-based ablation cannot copy might extend indication of the Cox maze procedure for patients with tough atrial fibrillation

    Distant Co-occurrence Patterns of Connectives: a Corpus Study of Formulaicity in Japanese

    Get PDF
    Using corpus research methods, this study aims to establish whether there are two-item and, more generally, multi-item distant co-occurrence patterns of connectives in written Japanese, and further, to clarify the role these patterns play in discourse. The study is based on a hybrid corpus of written Japanese including Humanities and social science papers, Science and technology papers, and general written language data. The co-occurrence threshold was set at co-occurrence frequency > 10, PMI value > 2, and Dice coefficient > 0.01. The distribution of the observed co-occurring pairs differed according to the genre. Visualization of the connectivity potential of co-occurring pairs as directed graphs showed that these co-occurring pairs constitute longer co-occurrence chains which can be interpreted as ready-made co-occurrence patterns. Two-item and multi-item co-occurrence patterns are considered a type of Bourdieu’s habitus and contribute to both discourse development and discourse prediction

    Chronic partial unloading restores β-adrenergic responsiveness and reverses receptor downregulation in failing rat hearts

    Get PDF
    ObjectivesMechanical unloading with a left ventricular assist device promotes “reverse remodeling,” including restoration of β-adrenergic receptor signaling and function. We compared the effects of partial unloading and complete unloading on β-adrenergic responsiveness and gene expressions in failing rat hearts by use of heterotopic heart–lung or heart transplantation models.MethodsFour weeks after ligation of the left anterior descending artery in Lewis rats, rats with heart failure were divided into 3 groups: infarcted hearts and lungs transplanted into the recipient rats (heart failure–partial unloading, n = 8); infarcted hearts transplanted into the recipient rats (heart failure–complete unloading, n = 7); infarcted (heart failure, n = 8) hearts without transplantation. Normal rats (n = 7) were used as controls. Papillary muscle function and gene expressions were studied at 2 or 4 weeks after transplantation.ResultsIn 2-week models, baseline developed tension of papillary muscles significantly increased in heart failure–partial unloading and heart failure–complete unloading compared with heart failure (0.15 ± 0.07 and 0.12 ± 0.05 g/mm2 vs 0.02 ± 0.01 g/mm2, P < .05). However, in 4-week models, they decreased to 0.11 ± 0.03 and 0.10 ± 0.03 g/mm2. In 4-week but not in 2-week models, the increase from baseline in baseline developed tension produced by β-adrenergic stimulation (isoproterenol, 10−8 and 10−7 mol/L) was significantly increased in heart failure–partial unloading compared with heart failure–complete unloading and heart failure (P < .05). The mRNA expressions of brain natriuretic peptide and β1- and β2-adrenergic receptors were normalized in both 2- and 4-week models of heart failure–partial unloading.ConclusionsChronic partial unloading but not complete unloading improved β-adrenergic responsiveness and normalized brain natriuretic peptide and β1- and β2-adrenergic receptor mRNA expressions in the failing rat hearts

    Autosynchronized systolic unloading during left ventricular assist with a centrifugal pump

    Get PDF
    AbstractObjectives: The purpose of this study was to investigate how the inflow cannulation site of the left ventricular assist system with a centrifugal pump would influence cardiac function on failing heart models. Methods: In 10 sheep, a left ventricular assist system was instituted by an outflow cannula in the descending aorta, two inflow cannulas in the left atrium and the left ventricle, and connecting those cannulas to a magnetically suspended centrifugal pump. A conductance catheter and a tipped micromanometer for monitoring the pressure-volume loop were also inserted into the left ventricle. Myocardial oxygen consumption was directly measured. Heart failure was induced by injection of microspheres into the left main coronary artery. The assist rate was varied from 0% to 100% at each inflow cannulation site. Results: The pump flow with left ventricular cannulation increased during the systolic phase and decreased during the diastolic phase, whereas it was constant with left atrial cannulation. Ejection fraction with left atrial cannulation decreased as the assist rate increased, whereas that with left ventricular cannulation was maintained up to 75% assist. The external work with left atrial cannulation decreased gradually as the assist rate increased, whereas the external work with left ventricular cannulation did not decrease until the assist rate reached 75%. The myocardial oxygen consumption in both cannulations decreased proportionally as the assist rate increased; they were significantly less with left ventricular cannulation at the 100% assist rate than with left atrial cannulation. Conclusion: Left ventricular cannulation during left ventricular assistance maintains ejection fraction and effectively reduces oxygen consumption.J Thorac Cardiovasc Surg 2003;125:353-6

    Clinical Validation of a Multiplex Kit for RAS Mutations in Colorectal Cancer: Results of the RASKET (RAS KEy Testing) Prospective, Multicenter Study

    Get PDF
    AbstractBackgroundRAS (KRAS and NRAS) testing is required to predict anti-epidermal growth factor receptor (EGFR) treatment efficacy in metastatic colorectal cancer (CRC). Although direct sequencing (DS) with manual microdissection (MMD) is widely used, a diagnostic kit providing rapid detections of RAS mutations would be clinically beneficial. We evaluated the MEBGENTM RASKET KIT (RASKET KIT), a multiplex assay using PCR-reverse sequence specific oligonucleotide and xMAP® technology to concurrently detect exon 2, 3, and 4 RAS mutations in a short turnaround time (4.5h/96-specimens).MethodsFormalin-fixed paraffin-embedded (FFPE) tissues were obtained from 308 consenting patients with histologically-confirmed CRC at six hospitals in Japan. For the RASKET KIT, we used only 50–100ng DNA from each FFPE specimen not processed by MMD. The primary endpoint was the concordance rate between RAS mutations identified with the RASKET KIT and two reference assays (DS with MMD and TheraScreen® K-RAS Mutation Kit). As the secondary endpoints, we evaluated the concordance rate between DS and the RASKET KIT for RAS mutations in the wild-type KRAS exon 2 population and the genotyping performance of the RASKET KIT compared with DS.FindingsAmong 307 analyzable specimens, the reference assays detected 140 (45.6%, 140/307) RAS mutations: 111 KRAS exon 2 and 29 other (minor) RAS mutations. The RASKET KIT detected 143 (46.6%, 143/307) mutations: 114 KRAS exon 2 and 29 minor RAS mutations. The between-method concordance rate was 96.7% (297/307) (95% CI: 94.1–98.4%). Minor RAS mutations were detected in 15.7% (30/191) of the wild-type KRAS exon 2 population (n=191); the concordance rate was 98.4% (188/191) (95% CI: 95.5–99.7%). The concordance rate of RAS genotyping was 100% (139/139) (95% CI: 97–100%).InterpretationThe RASKET KIT provides rapid and precise detections of RAS mutations and consequently, quicker and more effective anti-EGFR therapy for CRC (Study ID: UMIN000011784).FundingMedical & Biological Laboratories Co., Ltd. (MBL). MBL had roles in study design, data collection, data analysis, and writing of the report for the study

    Nanocellulose Paper Semiconductor with a 3D Network Structure and Its Nano-Micro-Macro Trans-Scale Design

    Full text link
    Semiconducting nanomaterials with 3D network structures exhibit various fascinating properties such as electrical conduction, high permeability, and large surface areas, which are beneficial for adsorption, separation, and sensing applications. However, research on these materials is substantially restricted by the limited trans-scalability of their structural design and tunability of electrical conductivity. To overcome this challenge, a pyrolyzed cellulose nanofiber paper (CNP) semiconductor with a 3D network structure is proposed. Its nano-micro-macro trans-scale structural design is achieved by a combination of iodine-mediated morphology-retaining pyrolysis with spatially controlled drying of a cellulose nanofiber dispersion and paper-crafting techniques, such as microembossing, origami, and kirigami. The electrical conduction of this semiconductor is widely and systematically tuned, via the temperature-controlled progressive pyrolysis of CNP, from insulating (1012 ω cm) to quasimetallic (10-2 ω cm), which considerably exceeds that attained in other previously reported nanomaterials with 3D networks. The pyrolyzed CNP semiconductor provides not only the tailorable functionality for applications ranging from water-vapor-selective sensors to enzymatic biofuel cell electrodes but also the designability of macroscopic device configurations for stretchable and wearable applications. This study provides a pathway to realize structurally and functionally designable semiconducting nanomaterials and all-nanocellulose semiconducting technology for diverse electronics.Koga H., Nagashima K., Suematsu K., et al. Nanocellulose Paper Semiconductor with a 3D Network Structure and Its Nano-Micro-Macro Trans-Scale Design. ACS Nano, 16(6), 8630-8640, 2022. https://doi.org/10.1021/acsnano.1c10728

    キョケツセイ シンキンショウ ニ タイスル サシツ ケイセイジュツ ニ カンスル ケンキュウ

    No full text
    京都大学0048新制・論文博士博士(医学)乙第11716号論医博第1885号新制||医||907(附属図書館)23613UT51-2005-K520(主査)教授 和田 洋巳, 教授 北 徹, 教授 野間 昭典学位規則第4条第2項該当Doctor of Medical ScienceKyoto UniversityDA

    Korpus usvajanja tujega jezika za študente japonščine

    Get PDF
    Japanese language learners aim to acquire reading, listening, writing and speaking skills. We at the Hinoki project (https://hinoki-project.org/) have recently been working on the Natsume collocation search system (https://hinoki-project.org/natsume/), the Natane learner corpus to support Natsume (https://hinoki-project.org/natane/) and the Nutmeg writing support system (http://hinoki-project.org/nutmeg/). In order to test the effectiveness of Nutmeg, we conducted an online experiment with 36 participants who used the system's register misuse identification feature to correct four writing assignments. Results show that Nutmeg can be an effective tool in correcting common register-related errors, especially those involving auxiliary verbs. However, the accuracy of verb and adverb identification was too low, suggesting the need for improvements in the variety of corpora used for identifying register misuse.Cilj vsakogar, ki se uči tuj jezik, je, da usvoji branje, slušno razumevanje, pisanje in govorne sposobnosti ciljnega jezika. S projektom Hinoki (https://hinoki-project.org/) si prizadevamo narediti iskalnik kolokacij Natsume (https://hinoki-project.org/natsume/), učni korpus Natane, ki bo podpiral Natsume (https://hinoki-project.org/natane/) in podporni sistem Nutmeg za pisanje (http://hinoki-project.org/nutmeg/). S spletnim eksperimentom, ki je vključeval 39 sodelujočih, smo ocenili učinkovitost sistema Nutmeg. Vsak sodelujoči je s pomočjo uporabe identifikacijskih lastnosti za napačno uporabo jezikovnega registra, ki jih ponuja sistem Nutmeg, popravil štiri pisne naloge. Rezultati kažejo, da je sistem Nutmeg učinkovito orodje za popravljanje splošnih napak, ki so povezane z registrom jezika, še posebej v primerih pomožnih glagolov. Hkrati smo ugotovili, da je prišlo do nepravilnosti pri prepoznavanju glagolov in prislovov, zaradi česar bo potrebno povečati raznolikost korpusov, na katerih prepoznavamo napačno uporabo jezikovnega registra
    corecore