55 research outputs found

    Raman and Rayleigh Calibrations of the LHD YAG Thomson Scattering

    Get PDF
    We have carried out absolute calibrations of the LHD YAG Thomson scattering system by using Raman scattering and Rayleigh scattering in order to verify the applicability of Rayleigh calibration in the LHD Thomson scattering, and make a comparative study of Raman and Rayleigh calibrations. In the LHD Thomson scattering device, Rayleigh calibration is expected to give more reliable calibration factors. For the Rayleigh calibration, additional Rayleigh channel was installed into 20 polychromators. The other 124 polychromators without Rayleigh channel were calibrated by only Raman scattering. In the Raman calibration, pure gaseous nitrogen was introduced into the LHD vacuum vessel whereas the Rayleigh calibration was made by using air as target gas. The calibration factors obtained from the Raman and Rayleigh calibrations show good agreements. Uncertainties in the calibration factors obtained from the Raman and Rayleigh calibrations are discussed

    Relationships between the Prediction of Linear MHD Stability Criteria and the Experiment in LHD

    Get PDF
    We analyze the relationship between the experimentally observed pressure gradients at resonant rational surfaces and the theoretically predicted ideal magnetohydrodynamics (MHD) unstable region of global modes in the large helical device (LHD). According to the stability analysis of the ideal MHD modes with a low toroidal mode number, we find that the ideal MHD mode gives a constraint on the operational regime of the pressure gradients in the core. In the edge, a clear saturation of the pressure gradients due to the ideal MHD instability has not been observed up to the high beta regime around 3% as the volume-averaged toridal beta value, where global ideal MHD modes are predictedto be unstable

    The Effect of Non-Axisymmetry of Magnetic Configurations on Radial Electric Field Transition Properties in the LHD

    Get PDF
    Transition property of the radial electric field (Er) in LHD have been theoretically investigated and also applied to explain experimental results. Especially, effects of the helicity of the magnetic configuration on the condition to realize the electron root are examined. Larger helicity makes the threshold collisionality higher. This is attributed to the nonlinear dependence of Γe(Er) in a low collisional regime. This interesting feature predicts that the threshold temperature becomes higher for a case of smaller helicity. The variation of the threshold density anticipated from the analysis for cases with different magnetic axis position is qualitatively verified in the density scan experiment

    Spatial resolved high-energy particle diagnostic system using time-of-flight neutral particle analyzer in Large Helical Device

    Get PDF
    The time-of-flight-type neutral particle analyzer has an ability of horizontal scanning from 40 to 100° of the pitch angle. The information from the spatially resolved energy spectrum gives not only the ion temperature but also the information of the particle confinement and the electric field in plasmas. We have been studying the energy distributions at various magnetic configurations in the neutral beam injection (NBI) plasma. The spatially resolved energy spectra can be observed during long discharges of the NBI plasma by continuous scanning of the neutral particle analyzer. The shape of spectra is almost similar from 44° to 53°. However, the spectra from 55° are strongly varied. They reflect the injection pitch angle of the beam. The pitch angle scanning experiment during the long discharge of NBI plasma has also been made under the reversal of the magnetic field direction. NBI2 becomes counter injected with the reversal. We can easily observe the difference between co- and counter injections of NBI. During the electron cyclotron heating in the low-density plasma for the formation of the internal thermal barrier, large neutral particle increase or decease can be observed. The degree of the increase/decrease depends on the energy and the density. The reason for the variation of the particle flux is that the orbit of the trapped particle changes due to the electric field formed by the strong electron cyclotron heating

    Present Status in the Development of 6 MeV Heavy Ion Beam Probe on LHD

    Get PDF
    In order to measure the potential in Large Helical Device (LHD), we have been developing a heavy ion beam probe (HIBP). For probing beam, gold beam is used, which is accelerated by a tandem accelerator up to the energy of 6 MeV. The experiments for calibration of beam orbit were done, and experimental results were compared with orbit calculations. The experimental results coincided fairly with the calculation results. After the calibration of the beam orbit, the potential in plasma was tried to measure with the HIBP. The experimental data showed positive potential in a neutral beam heating phase on the condition of ne ? 5 × 10^18 m^-3, and the increase of potential was observed when the additional electron cyclotron heating was applied to this plasma. The time constant for this increase was about a few tens ms, which was larger than a theoretical expectation. In the spatial position of sample volume, we might have an ambiguity in this experiment

    Recent Results from LHD Experiment with Emphasis on Relation to Theory from Experimentalist’s View

    Get PDF
    he Large Helical Device (LHD) has been extending an operational regime of net-current free plasmas towardsthe fusion relevant condition with taking advantage of a net current-free heliotron concept and employing a superconducting coil system. Heating capability has exceeded 10 MW and the central ion and electron temperatureshave reached 7 and 10 keV, respectively. The maximum value of β and pulse length have been extended to 3.2% and 150 s, respectively. Many encouraging physical findings have been obtained. Topics from recent experiments, which should be emphasized from the aspect of theoretical approaches, are reviewed. Those are (1) Prominent features in the inward shifted configuration, i.e., mitigation of an ideal interchange mode in the configuration with magnetic hill, and confinement improvement due to suppression of both anomalous and neoclassical transport, (2) Demonstration ofbifurcation of radial electric field and associated formation of an internal transport barrier, and (3) Dynamics of magnetic islands and clarification of the role of separatrix

    A Movable Thomson Scattering System Based on Optical Fibers (TS-Probe)

    Get PDF
    This paper proposes a movable compact Thomson scattering (TS) system based on optical fibers (TS-probe). The TS-probe consists of a probe head, optical fibers, a laser diode, a polychromator, and lock-in amplifiers. Laser beam optics and light collection optics are mounted rigidly on a probe head with a fixed scattering position. Laser light and scattered light are transmitted by flexible optical fibers, enabling us to move the TS-probe head freely during plasma discharge. The light signal scattered from an amplitude-modulated laser is detected against the plasma light based on the principle of the lock-in amplifier. With a modulated laser power of 300 W, the scattered signal from a sheet plasma 15 mm deep with ne ?1019 m?3 can be measured with 10 % accuracy by setting the integrating time to 0.1 s. The TS-probe head is similar to a 1/20 model of the currently operating Large Helical Device-TS
    • …
    corecore