11 research outputs found

    Fissure Seal or Fluoride Varnish? A Randomized Trial of Relative Effectiveness

    Get PDF
    Fissure sealant (FS) and fluoride varnish (FV) are effective in preventing dental caries when compared with a no-treatment control. However, the relative clinical effectiveness of these interventions is uncertain. The objective of the study was to compare the clinical effectiveness of FS and FV in preventing dental caries in first permanent molars (FPMs) in 6- to 7-y-olds. The study design was a randomized clinical trial, with 2 parallel arms. The setting was a targeted-population program that used mobile dental clinics in schools located within areas of high social and economic deprivation in South Wales. A total of 1,016 children were randomized 1:1 to receive either FS or FV. Resin-based FS was applied to caries-free FPMs and maintained at 6-mo intervals. FV was applied at baseline and at 6-mo intervals for 3 y. The main outcome measures were the proportion of children developing caries into dentine (D4-6MFT) on any 1 of up to 4 treated FPMs after 36 mo. At 36 mo, 835 (82%) children remained: 417 in the FS arm and 418 in the FV arm. A smaller proportion of children who received FV (n = 73, 17.5%) versus FS (n = 82, 19.6%) developed caries into dentine on at least 1 FPM (odds ratio [OR] = 0.84; 95% CI, 0.59 to 1.21; P = 0.35), a nonstatistically significant difference between FS and FV treatments. The results were similar when the number of newly decayed teeth (OR = 0.86; 95% CI, 0.60 to 1.22) and tooth surfaces (OR = 0.85; 95% CI, 0.59 to 1.21) were examined. In a community oral health program, semiannual application of FV resulted in caries prevention that was not significantly different from that obtained by applying and maintaining FS after 36 mo (EudraCT: 2010-023476-23; ISRCTN: ISRCTN17029222)

    The development and validation of a disease-specific quality of life measure in hyperhidrosis : the Hyperhidrosis Quality of Life Index (HidroQOL©)

    Get PDF
    This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original authors and the source are credited.PURPOSE: To develop and validate a new disease-specific quality of life measure in hyperhidrosis for use in both routine clinical practice and clinical research. METHODS: Interviews and focus group discussions with hyperhidrosis patients, reported elsewhere, provided the content for the measure validated in this study (n = 71). A panel of dermatologists (n = 5) and patients (n = 7) carried out content validation. Further, item reduction and the initial construct validation were carried out in a cross-sectional study (n = 595), using the unidimensional Rasch analysis and exploratory factor analysis. Subsequently, the construct validity, reliability and responsiveness of the revised measure were assessed in a longitudinal study (n = 260). Data collection for the item reduction and the final validation phases was entirely carried out online. RESULTS: The expert panels judged the HidroQoL as content valid. Rasch analysis supported the revision of response options from five to three. Following removal of misfitting items, a set of 15 items showed optimal fit to the model (chi-squared statistic = 159.64, p = 0.07). Three additional items were retained on consideration of their importance to patients, resulting in an 18-item instrument. The items were grouped into two subscales, daily life activities and psychosocial life domains, based on results of the factor analysis. In subsequent construct validation, the HidroQoL correlated with the DLQI (r s = 0.6, p < 0.01). Reliability was high (internal consistency, Cronbach's alpha: overall scale = 0.9; test-retest reliability, Intra-class correlation = 0.9). The HidroQoL scores were sensitive to change in patients' disease severity (score change from baseline to follow-up after 15-35 days, Cohen's ES = 0.47). CONCLUSION: This study has provided the initial evidence supporting measurement properties and the use of the HidroQoL instrument in both routine clinical practice and in research, for assessing quality of life impacts in hyperhidrosis.Peer reviewedFinal Published versio

    Particle Swarm Optimization of Coupled Electromechanical Systems

    Full text link

    Viscoelastometric-guided early fibrinogen concentrate replacement during postpartum haemorrhage: OBS2, a double-blind randomized controlled trial

    Get PDF
    Background: Postpartum haemorrhage (PPH) can be exacerbated by haemostatic failure. We hypothesized that early fibrinogen replacement, guided by viscoelastometric testing, reduces blood product usage and bleed size. Methods: Women with PPH 1000–1500 ml were enrolled. If Fibtem A5 was ≤15 mm and bleeding continued, subjects were randomized to fibrinogen concentrate or placebo. The primary outcome compared the number of units of red blood cells, plasma, cryoprecipitate and platelets transfused. Results: Of 663 women enrolled 55 were randomized. The adjusted incidence rate ratio (IRR) (95% CI) for the number of allogeneic units transfused in the fibrinogen group compared with placebo was 0.72 (0.3–1.7), P=0.45. In pre-specified subgroup analyses, subjects who had a Fibtem A5 ≤12 mm at the time of randomization and who received fibrinogen concentrate received a median (25th–75th centile) of 1 (0–4.5) unit of allogeneic blood products and had an additional 300 (100–350) ml blood loss whereas those who received placebo also received 3 (0–6) units of allogeneic blood products and had 700 (200–1550) ml additional blood loss; these differences were not statistically significantly different. There was one thrombotic event in each group. Conclusions: Infusion of fibrinogen concentrate triggered by Fibtem A5 ≤15 mm did not improve outcomes in PPH. Pre-specified subgroup analyses suggest that fibrinogen replacement is not required if the Fibtem A5 is > 12 mm or Clauss fibrinogen >2 g litre−1, but an effect below these levels cannot be excluded. The raised fibrinogen at term appears to be a physiological buffer rather than required for haemostasi

    Viscoelastometry guided fresh frozen plasma infusion for postpartum haemorrhage: OBS2, an observational study

    Get PDF
    Background Postpartum haemorrhage (PPH) may be exacerbated by haemostatic failure. Based on data from trauma studies, empirical infusions of fresh frozen plasma (FFP) are often given during severe PPH if coagulation tests are unavailable. This study observed a cohort of women with moderate/severe PPH in whom FFP infusion was guided by the use of viscoelastometric point-of-care testing (VEPOCT) and clinical assessment. Methods Women were enrolled into this observational study when blood loss was measured or suspected to be about 1000 mL. If Fibtem A5 remained >15 mm, or bleeding stopped, FFP was withheld. If Fibtem A5 was ≤15 mm and bleeding ongoing women were randomised into an interventional study as previously reported. Clinical and laboratory outcomes were recorded. Results The study recruited 605 women and 98% had FFP withheld. The median (25th-75th centile) total blood loss was 1500 (1300-2000) mL with 300 (50-545) mL occurring after enrolment. Total blood loss was >2500 mL in 40/605 (6.6%) women. RBCs were transfused in 141/605 (23.3%) cases and 11 (1.8%) received ≥4 units. At least one invasive procedure was performed in 283/605 (46.8%) women. Level 3 care was required for 10/605 (1.7%) women. No women developed clinically significant haemostatic impairment. Conclusions A restrictive use of FFP guided by clinical assessment of bleeding and VE-POCT is feasible and did not result in clinically significant haemostatic impairment. Studies should compare the clinical and cost effectiveness of empirical FFP infusions, according to current guidelines, with a targeted use of FFP based on VE-POCT
    corecore