1,751 research outputs found
Comparing verbal media for alarm handling: Speech versus textual displays
The rise of computers in command and control domains has meant that control operations can be performed via desk-based visual display terminals. This trend has also produced the potential to display information to operators in a variety of formats. Of particular interest has been the use of text-based displays for alarm presentation. There are possible limitations to the use of text for alarm presentation, not least of which is the need for a dedicated alarms display screen (or, at least, a display page). Given the capability of computers to synthesize speech, it is possible that speech-based alarms could generate the same information as text-based displays without the need for dedicated screen space. In this paper an experimental comparison of speech-based and text-based displays for presentation of alarms is reported. The findings show that speech leads to longer response times than text displays, but that it has minimal effect on the efficacy of fault handling. The results are discussed within the alarm initiated activities framework and implications for alarm system design are outlined
Task analysis for error identification: Theory, method and validation
This paper presents the underlying theory of Task Analysis for Error Identification. The aim is to illustrate the development of a method that has been proposed for the evaluation of prototypical designs from the perspective of predicting human error. The paper presents the method applied to representative examples. The methodology is considered in terms of the various validation studies that have been conducted, and is discussed in the light of a specific case study
The ergonomics of command and control
Since its inception, just after the Second World War, ergonomics research has paid special attention to the issues surrounding human control of systems. Command and Control environments continue to represent a challenging domain for Ergonomics research. We take a broad view of Command and Control research, to include C2 (Command and Control), C3 (Command, Control and Communication), and C4 (Command, Control, Communication and Computers) as well as human supervisory control paradigms. This special issue of ERGONOMICS aims to present state-of-the-art research into models of team performance, evaluation of novel interaction technologies, case studies, methodologies and theoretical review papers. We are pleased to present papers that detail research on these topics in domains as diverse as the emergency services (e.g., police, fire, and ambulance), civilian applications (e.g., air traffic control, rail networks, and nuclear power) and military applications (e.g., land, sea and air) of command and control. While the domains of application are very diverse, many of the challenges they face share interesting similarities
WESTT (Workload, Error, Situational Awareness, Time and Teamwork): An analytical prototyping system for command and control
Modern developments in the use of information technology within command and control allow unprecedented scope for flexibility in the way teams deal with tasks. These developments, together with the increased recognition of the importance of knowledge management within teams present difficulties for the analyst in terms of evaluating the impacts of changes to task composition or team membership. In this paper an approach to this problem is presented that represents team behaviour in terms of three linked networks (representing task, social network structure and knowledge) within the integrative WESTT software tool. In addition, by automating analyses of workload and error based on the same data that generate the networks, WESTT allows the user to engage in the process of rapid and iterative “analytical prototyping”. For purposes of illustration an example of the use of this technique with regard to a simple tactical vignette is presented
Recommended from our members
Synthesis of Silver Nanoparticles using Non-Fouling Microfluidic Devices with Fast Mixing
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.Silver nanoparticles were synthesized in an impinging jet reactor using silver nitrate as a precursor, trisodium citrate as a stabilizer and sodium borohydride as a reducing agent. The effect of mixing time on the nanoparticle morphology was investigated by means of UV-Vis spectroscopy, used as a characterization tool. It was observed that as the mixing time became shorter the nanoparticles retained a similar average diameter but produced more aggregates. The mixing time was characterized using the ‘Villermaux-Dushmann’ reaction system together with the Interaction by Exchange with the Mean mixing model. The mixing time achieved was of the order of a few ms for flowrates in the range 18-28 ml/min. The synthesis of silver nanoparticles was carried out at the same flowrates to link mixing time to silver nanoparticle morphology
Ischemic colitis or melanosis coli: a case report
<p>Abstract</p> <p>Background</p> <p>Melanosis Coli is described as black or brown discolouration of the mucosa of the colon. Its a benign condition, which arises from anthraquinone laxative abuse and has no symptoms of its own. The main importance of diagnosing Melanosis Coli correctly lies in the fact that if its extensive, there may be difficulty in differentiating it from ischemic colitis.</p> <p>Case presentation</p> <p>We present a case of extensive Melanosis Coli involving the whole of large bowel that appeared gangrenous. A sub total colectomy was performed on presumed diagnosis of ischemic bowel.</p> <p>Conclusion</p> <p>This report reminds the clinicians that extensive Melanosis Coli may mimic ischemic colitis and thus must be considered as a differential diagnosis.</p
A detailed study of quasinormal frequencies of the Kerr black hole
We compute the quasinormal frequencies of the Kerr black hole using a
continued fraction method. The continued fraction method first proposed by
Leaver is still the only known method stable and accurate for the numerical
determination of the Kerr quasinormal frequencies. We numerically obtain not
only the slowly but also the rapidly damped quasinormal frequencies and analyze
the peculiar behavior of these frequencies at the Kerr limit. We also calculate
the algebraically special frequency first identified by Chandrasekhar and
confirm that it coincide with the quasinormal frequency only at the
Schwarzschild limit.Comment: REVTEX, 15 pages, 7 eps figure
Synthesis of silver nanoparticles using nonfouling microfluidic devices with fast mixing
Silver nanoparticles were synthesized in an impinging jet reactor using silver nitrate as a
precursor, trisodium citrate as a stabilizer and sodium borohydride as a reducing agent. The effect of mixing
time on the nanoparticle morphology was investigated by means of UV-Vis spectroscopy, used as a
characterization tool. It was observed that as the mixing time became shorter the nanoparticles retained a
similar average diameter but produced more aggregates. The mixing time was characterized using the
‘Villermaux-Dushmann’ reaction system together with the Interaction by Exchange with the Mean mixing
model. The mixing time achieved was of the order of a few ms for flowrates in the range 18-28 ml/min. The
synthesis of silver nanoparticles was carried out at the same flowrates to link mixing time to silver
nanoparticle morphology
- …