227 research outputs found
Apodization in high-contrast long-slit spectroscopy. Closer, deeper, fainter, cooler
The spectroscopy of faint planetary-mass companions to nearby stars is one of
the main challenges that new-generation high-contrast spectro-imagers are going
to face. In a previous work we presented a long slit coronagraph (LSC), for
which the presence of a slit in the coronagraphic focal plane induces a complex
distribution of energy in the Lyot pupil-plane that cannot be easily masked
with a binary Lyot stop. To alleviate this concern, we propose to use a pupil
apodization to suppress diffraction, creating an apodized long slit coronagraph
(ALSC). After describing how the apodization is optimized, we demonstrate its
advantages with respect to the CLC in the context of SPHERE/IRDIS long slit
spectroscopy (LSS) mode at low-resolution with a 0.12" slit and 0.18"
coronagraphic mask. We perform different sets of simulations with and without
aberrations, and with and without a slit to demonstrate that the apodization is
a more appropriate concept for LSS, at the expense of a significantly reduced
throughput (37%) compared to the LSC. Then we perform detailed end-to-end
simulations of the LSC and the ALSC that include realistic levels of
aberrations to obtain datasets representing 1h of integration time on stars of
spectral types A0 to M0 located at 10 pc. We insert spectra of planetary
companions at different effective temperatures (Teff) and surface gravities
(log g) into the data at angular separations of 0.3" to 1.5" and with contrast
ratios from 6 to 18 mag. Using the SD method to subtract the speckles, we show
that the ALSC brings a gain in sensitivity of up to 3 mag at 0.3" with respect
to the LSC, which leads to a much better spectral extraction below 0.5". In
terms of Teff, we demonstrate that at small angular separations the limit with
the ALSC is always lower by at least 100K, inducing an increase of sensitivity
of a factor up to 1.8 in objects' masses at young ages. [Abridged]Comment: 15 pages, 17 figures. Accepted for publication in A&
Calibration of quasi-static aberrations in exoplanet direct-imaging instruments with a Zernike phase-mask sensor
Context. Several exoplanet direct imaging instruments will soon be in
operation. They use an extreme adaptive optics (XAO) system to correct the
atmospheric turbulence and provide a highly-corrected beam to a near-infrared
(NIR) coronagraph for starlight suppression. The performance of the coronagraph
is however limited by the non-common path aberrations (NCPA) due to the
differential wavefront errors existing between the visible XAO sensing path and
the NIR science path, leading to residual speckles in the coronagraphic image.
Aims. Several approaches have been developed in the past few years to
accurately calibrate the NCPA, correct the quasi-static speckles and allow the
observation of exoplanets at least 1e6 fainter than their host star. We propose
an approach based on the Zernike phase-contrast method for the measurements of
the NCPA between the optical path seen by the visible XAO wavefront sensor and
that seen by the near-IR coronagraph. Methods. This approach uses a focal plane
phase mask of size {\lambda}/D, where {\lambda} and D denote the wavelength and
the telescope aperture diameter, respectively, to measure the quasi-static
aberrations in the upstream pupil plane by encoding them into intensity
variations in the downstream pupil image. We develop a rigorous formalism,
leading to highly accurate measurement of the NCPA, in a quasi-linear way
during the observation. Results. For a static phase map of standard deviation
44 nm rms at {\lambda} = 1.625 {\mu}m (0.026 {\lambda}), we estimate a possible
reduction of the chromatic NCPA by a factor ranging from 3 to 10 in the
presence of AO residuals compared with the expected performance of a typical
current-generation system. This would allow a reduction of the level of
quasi-static speckles in the detected images by a factor 10 to 100 hence,
correspondingly improving the capacity to observe exoplanets.Comment: 11 pages, 14 figures, A&A accepted, 2nd version after language-editor
correction
Micromagnetism in (001) magnetite by spin-polarized low-energy electron microscopy
Spin-polarized low-energy electron microscopy was used to image a magnetite
crystal with (100) surface orientation. Sets of spin-dependent images of
magnetic domain patterns observed in this surface were used to map the
direction of the magnetization vector with high spatial and angular resolution.
We find that domains are magnetized along the surface [110] directions, and
domain wall structures include 90{\deg} and 180{\deg} walls. A type of
unusually curved domain walls are interpreted as N\'eel-capped surface
terminations of 180{\deg} Bloch walls.Comment: 17 pages, 4 figures. Presented at the LEEM-PEEM 8 conferenc
Laboratory validation of the dual-zone phase mask coronagraph in broadband light at the high-contrast imaging THD-testbed
Specific high contrast imaging instruments are mandatory to characterize
circumstellar disks and exoplanets around nearby stars. Coronagraphs are
commonly used in these facilities to reject the diffracted light of an observed
star and enable the direct imaging and spectroscopy of its circumstellar
environment. One important property of the coronagraph is to be able to work in
broadband light.
Among several proposed coronagraphs, the dual-zone phase mask coronagraph is
a promising solution for starlight rejection in broadband light. In this paper,
we perform the first validation of this concept in laboratory.
First, we recall the principle of the dual-zone phase mask coronagraph. Then,
we describe the high-contrast imaging THD testbed, the manufacturing of the
components and the quality-control procedures. Finally, we study the
sensitivity of our coronagraph to low-order aberrations (inner working angle
and defocus) and estimate its contrast performance. Our experimental broadband
light results are compared with numerical simulations to check agreement with
the performance predictions.
With the manufactured prototype and using a dark hole technique based on the
self-coherent camera, we obtain contrast levels down to between 5
and 17 in monochromatic light (640 nm). We also reach contrast
levels of between 7 and 17 in broadband
( nm, nm and %), which demonstrates the excellent chromatic performance of the dual-zone
phase mask coronagraph.
The performance reached by the dual-zone phase mask coronagraph is promising
for future high-contrast imaging instruments that aim at detecting and
spectrally characterizing old or light gaseous planets.Comment: 9 pages, 16 figure
Errors recruit both cognitive and emotional monitoring systems: Simultaneous intracranial recordings in the dorsal anterior cingulate gyrus and amygdala combined with fMRI
We studied error monitoring in a human patient with unique implantation of depth electrodes in both the left dorsal cingulate gyrus and medial temporal lobe prior to surgery. The patient performed a speeded go/nogo task and made a substantial number of commission errors (false alarms). As predicted, intracranial Local Field Potentials (iLFPs) in dorsal anterior cingulate indexed the detection of errors, showing an early differential activity around motor execution for false alarms, relative to correct responses (either hits or correct inhibitions). More surprisingly, we found that the left amygdala also participated to error monitoring (although no emotional stimuli were used), but with a very different neurophysiological profile as compared with the dorsal cingulate cortex. Amygdala iLFPs showed a precise and reproducible temporal unfolding, characterized by an early monophasic response for correct hits around motor execution, which was delayed by approximately 300ms for errors (even though actual RTs were almost identical in these two conditions). Moreover, time-frequency analyses demonstrated a reliable and transient coupling in the theta band around motor execution between these two distant regions. Additional fMRI investigation in the same patient confirmed a differential involvement of the dorsal cingulate cortex vs. amygdala in error monitoring during this go/nogo task. Finally, these intracranial results for the left amygdala were replicated in a second patient with intracranial electrodes in the right amygdala. Altogether, these results suggest that the amygdala may register the motivational significance of motor actions on a trial-by-trial basis, while the dorsal anterior cingulate cortex may provide signals concerning failures of cognitive control and behavioral adjustment. More generally, these data shed new light on neural mechanisms underlying self-monitoring by showing that even "simple" motor actions recruit not only executive cognitive processes (in dorsal cingulate) but also affective processes (in amygdala)
- …