529 research outputs found

    Performance of SSE and AVX Instruction Sets

    Full text link
    SSE (streaming SIMD extensions) and AVX (advanced vector extensions) are SIMD (single instruction multiple data streams) instruction sets supported by recent CPUs manufactured in Intel and AMD. This SIMD programming allows parallel processing by multiple cores in a single CPU. Basic arithmetic and data transfer operations such as sum, multiplication and square root can be processed simultaneously. Although popular compilers such as GNU compilers and Intel compilers provide automatic SIMD optimization options, one can obtain better performance by a manual SIMD programming with proper optimization: data packing, data reuse and asynchronous data transfer. In particular, linear algebraic operations of vectors and matrices can be easily optimized by the SIMD programming. Typical calculations in lattice gauge theory are composed of linear algebraic operations of gauge link matrices and fermion vectors, and so can adopt the manual SIMD programming to improve the performance.Comment: 7 pages, 5 figures, 4 tables, Contribution to proceedings of the 30th International Symposium on Lattice Field Theory (Lattice 2012), June 24-29, 201

    Successful management of heterotopic cornual pregnancy with laparoscopic cornual resection

    Get PDF
    AbstractObjectiveTo examine the feasibility of laparoscopic cornual resection for the treatment of heterotopic cornual pregnancy.Study designWomen who underwent laparoscopic cornual resection for heterotopic cornual pregnancy at our hospital between January 2003 and March 2015 were retrospectively analyzed. We evaluated significant parameters such as operative complications and postoperative pregnancy outcomes of concomitant pregnancy.ResultsThirteen patients with heterotopic cornual pregnancy were included in the study. All were pregnant through assisted reproductive technology, and the diagnosis was made at a median of 6+6 weeks (range 5+4–10+0). They were successfully treated with laparoscopic cornual resection and admitted for a median of 4 days (range, 2–7) postoperatively. The median operative time was 65min (range, 35–145min) and estimated blood loss was 200mL (range, 10–3000mL). There was a spontaneous abortion at 7+6 gestational weeks in a patient who received bilateral cornual resection. Seven patients delivered babies at term and 3 at preterm. All 10 women delivered without any maternal or neonatal complications. Two were lost to follow-up.ConclusionsLaparoscopic cornual resection is a feasible primary approach for the management of heterotopic cornual pregnancy

    Transient postoperative inferior subluxation of the shoulder after surgical stabilization of recurrent anterior dislocation in a patient with myasthenia gravis: a case report

    Get PDF
    The authors present a case of transient postoperative inferior subluxation of the shoulder after arthroscopic surgical stabilization for recurrent anterior dislocation. The patient was a 61-year-old woman with myasthenia gravis (MG). The first anterior shoulder dislocation occurred because of a fall to the ground. Despite a successful closed reduction, two more dislocations occurred in 3 weeks. Magnetic resonance imaging revealed an anterior labroligamentous periosteal sleeve avulsion (ALPSA) lesion, an engaging Hill-Sachs lesion, and large tears of the supraspinatus and infraspinatus tendons. The patient underwent arthroscopic rotator cuff repair and ALPSA repair with a remplissage procedure. Intraoperatively, no tendency for instability was found; however, a widened glenohumeral joint space and inferior subluxation of the humeral head without functional compromise was observed on the day after surgery and disappeared spontaneously on radiographs 2 weeks later. To the authors’ knowledge, this is the first report documenting the occurrence of transient postoperative inferior subluxation of the shoulder in a patient with MG. Level of evidence V

    Comparison of long-term clinical outcomes among zotarolimus-, everolimus-, and biolimus-eluting stents in acute myocardial infarction patients with renal impairment

    Get PDF
    Background: It is important to determine the best drug-eluting stent (DES) for acute myocardial infarction (AMI) in patients with renal impairment. In this studythe outcomes of everolimus-eluting stents (EESs), zotarolimus-eluting stents (ZESs) and biolimus-eluting stents (BESs) were evaluated. Methods: From the Korea Acute Myocardial Infarction-National Institutes of Health registry, a total of 1,470 AMI patients with renal impairment undergoing percutaneous coronary intervention (PCI) were enrolled (816 with EES, 345 with ZES, and 309 with BES). Renal impairment was defined as creatinine clearance < 60 mL/min/1.73 m2 estimated by the Cockcroft-Gault method. Major adverse cardiac and cerebrovascular events were determined as the composite of all-cause death, non-fatal myocardial infarction (MI), cerebrovascular accident, any revascularization, rehospitalization and stent thrombosis. All clinical outcomes were analyzed. Results: The baseline characteristics of the patients revealed no significant difference between the three groups, except for Killip classification > 2, beta-blockers, lesion type, vascular approach, staged PCI, left main coronary artery (LMCA) complex lesions, LMCA PCI, and the number and length of implanted stents. In the Kaplan-Meier analysis, similar clinical outcomes were derived from the unadjusted data between the three DES groups. However, after the inverse probability of treatment weighting, a statistically significant difference was found in non-fatal MI, which implied a higher incidence of non-fatal MI in the ZES group than in the other two DES groups. Conclusions: In AMI patients with renal impairment, there was no significant difference between the three stent groups in terms of long-term clinical outcomes, except for non-fatal MI

    AKARI Detection of the Infrared-Bright Supernova Remnant B0104-72.3 in the Small Magellanic Cloud

    Full text link
    We present a serendipitous detection of the infrared-bright supernova remnant (SNR) B0104-72.3 in the Small Magellanic Cloud by the Infrared Camera (IRC) onboard AKARI. An elongated, partially complete shell is detected in all four observed IRC bands covering 2.6-15 um. The infrared shell surrounds radio, optical, and X-ray emission associated with the SNR and is probably a radiative SNR shell. This is the first detection of a SNR shell in this near/mid-infrared waveband in the Small Magellanic Cloud. The IRC color indicates that the infrared emission might be from shocked H2 molecules with some possible contributions from ionic lines. We conclude that B0104-72.3 is a middle-aged SNR interacting with molecular clouds, similar to the Galactic SNR IC 443. Our results highlight the potential of AKARI IRC observations in studying SNRs, especially for diagnosing SNR shocks.Comment: 12 pages with 3 figures, accepted for publication in AKARI PASJ special issu

    Very Late Stent Thrombosis after Drug-Eluting Stent Implantation in a Patient without Aspirin and Clopidogrel Resistance

    Get PDF
    Very late stent thrombosis (VLST) after implantation of drug-eluting stent is rare, but very fatal complication after percutaneous coronary intervention. We report a case of VLST of a sirolimus-eluting Cypher™ stent (Cordis, Johnson and Johnson) presenting as acute ST elevation myocardial infarction at 26 months after deployment with continued combined dual antiplatelet medication of aspirin and clopidogrel. The patient did not show anti-platelet resistance

    Case report: A fatal case of myocardial infarction due to myocardial bridge and concomitant vasospasm: the role of stress gated SPECT

    Get PDF
    IntroductionAlthough most cases of myocardial bridge (MB) are clinically benign, sometimes it can be one of potential threats of myocardial infarction (MI) and life-threatening arrhythmia. In the present study, we present a case of ST-segment elevation MI caused by MB and concomitant vasospasm.Case PresentationA 52-year-old woman was brought to our tertiary hospital due to resuscitated cardiac arrest. Because the 12-lead electrocardiogram indicated ST-segment elevation MI, coronary angiogram was promptly commenced, which showed near-total occlusion at the middle portion of left anterior descending coronary artery (LAD). After intracoronary nitroglycerin administration, this occlusion was dramatically relieved, however, systolic compression at this site remained, indicative of myocardial bridge (MB). Intravascular ultrasound also showed eccentric compression with a “half-moon” sign, which is consistent with MB. Coronary computed tomography also showed a bridged coronary segment surrounded by myocardium at the middle portion of LAD. To assess the severity and extent of myocardial damages and ischemia, myocardial single photon emission computed tomography (SPECT) was additionally conducted, showing a moderate fixed perfusion defect around the cardiac apex, suggesting MI. After receiving optimal medical therapy, the patient's clinical symptoms and signs were improved then the patient was discharged from the hospital successfully and uneventfully.ConclusionWe demonstrated a case of MB-induced ST-segment elevation MI which was confirmed with its perfusion defects via myocardial perfusion SPECT. There have been proposed a number of diagnostic modalities to examine its anatomic and physiologic significance. Among them, myocardial perfusion SPECT can be available as one of useful modalities to evaluate the severity and extent of myocardial ischemia in patients with MB
    • …
    corecore