41 research outputs found
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
We describe the design and performance the calorimeter systems used in the
ECCE detector design to achieve the overall performance specifications
cost-effectively with careful consideration of appropriate technical and
schedule risks. The calorimeter systems consist of three electromagnetic
calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and
two hadronic calorimeters. Key calorimeter performances which include energy
and position resolutions, reconstruction efficiency, and particle
identification will be presented.Comment: 19 pages, 22 figures, 5 table
ECCE Sensitivity Studies for Single Hadron Transverse Single Spin Asymmetry Measurements
We performed feasibility studies for various single transverse spin
measurements that are related to the Sivers effect, transversity and the tensor
charge, and the Collins fragmentation function. The processes studied include
semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions
and kaons) were detected in addition to the scattered DIS lepton. The data were
obtained in {\sc pythia}6 and {\sc geant}4 simulated e+p collisions at 18 GeV
on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector
configuration. Typical DIS kinematics were selected, most notably
GeV, and cover the range from to . The single spin
asymmetries were extracted as a function of and , as well as the
semi-inclusive variables , and . They are obtained in azimuthal moments
in combinations of the azimuthal angles of the hadron transverse momentum and
transverse spin of the nucleon relative to the lepton scattering plane. The
initially unpolarized MonteCarlo was re-weighted in the true kinematic
variables, hadron types and parton flavors based on global fits of fixed target
SIDIS experiments and annihilation data. The expected statistical
precision of such measurements is extrapolated to 10 fb and potential
systematic uncertainties are approximated given the deviations between true and
reconstructed yields. The impact on the knowledge of the Sivers functions,
transversity and tensor charges, and the Collins function has then been
evaluated in the same phenomenological extractions as in the Yellow Report. The
impact is found to be comparable to that obtained with the parameterized Yellow
Report detector and shows that the ECCE detector configuration can fulfill the
physics goals on these quantities.Comment: 22 pages, 22 figures, to be submitted to joint ECCE proposal NIM-A
volum
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
The ECCE detector has been recommended as the selected reference detector for
the future Electron-Ion Collider (EIC). A series of simulation studies have
been carried out to validate the physics feasibility of the ECCE detector. In
this paper, detailed studies of heavy flavor hadron and jet reconstruction and
physics projections with the ECCE detector performance and different magnet
options will be presented. The ECCE detector has enabled precise EIC heavy
flavor hadron and jet measurements with a broad kinematic coverage. These
proposed heavy flavor measurements will help systematically study the
hadronization process in vacuum and nuclear medium especially in the
underexplored kinematic region.Comment: Open heavy flavor studies with the EIC reference detector design by
the ECCE consortium. 11 pages, 11 figures, to be submitted to the Nuclear
Instruments and Methods
AI-assisted Optimization of the ECCE Tracking System at the Electron Ion Collider
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that
will study the nature of the "glue" that binds the building blocks of the
visible matter in the universe. The proposed experiment will be realized at
Brookhaven National Laboratory in approximately 10 years from now, with
detector design and R&D currently ongoing. Notably, EIC is one of the first
large-scale facilities to leverage Artificial Intelligence (AI) already
starting from the design and R&D phases. The EIC Comprehensive Chromodynamics
Experiment (ECCE) is a consortium that proposed a detector design based on a
1.5T solenoid. The EIC detector proposal review concluded that the ECCE design
will serve as the reference design for an EIC detector. Herein we describe a
comprehensive optimization of the ECCE tracker using AI. The work required a
complex parametrization of the simulated detector system. Our approach dealt
with an optimization problem in a multidimensional design space driven by
multiple objectives that encode the detector performance, while satisfying
several mechanical constraints. We describe our strategy and show results
obtained for the ECCE tracking system. The AI-assisted design is agnostic to
the simulation framework and can be extended to other sub-detectors or to a
system of sub-detectors to further optimize the performance of the EIC
detector.Comment: 16 pages, 18 figures, 2 appendices, 3 table
ECCE unpolarized TMD measurements
We performed feasibility studies for various measurements that are related to
unpolarized TMD distribution and fragmentation functions. The processes studied
include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons
(pions and kaons) were detected in addition to the scattered DIS lepton. The
single hadron cross sections and multiplicities were extracted as a function of
the DIS variables and , as well as the semi-inclusive variables ,
which corresponds to the momentum fraction the detected hadron carries relative
to the struck parton and , which corresponds to the transverse momentum of
the detected hadron relative to the virtual photon. The expected statistical
precision of such measurements is extrapolated to accumulated luminosities of
10 fb and potential systematic uncertainties are approximated given the
deviations between true and reconstructed yields.Comment: 12 pages, 9 figures, to be submitted in joint ECCE proposal NIM-A
volum
Recommended from our members
Design of the ECCE Detector for the Electron Ion Collider
Preprint submitted to Nuclear Instruments and Methods A. The file archived on this institutional repository has not been certified by peer review.32 pages, 29 figures, 9 tablesThe EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. This detector concept has been selected to be the basis for the EIC project detector.Office of Science in the Department of Energy, the National Science Foundation, and the Los Alamos National
Laboratory Laboratory Directed Research and Development (LDRD) 20200022DR; This research used resources of the Compute and Data Environment for Science (CADES) at the Oak Ridge National Laboratory, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-
00OR22725. The work of AANL group are supported by the Science Committee of RA, in the frames of the research project # 21AG-1C028. And we gratefully acknowledge that support of Brookhaven National Lab and the Thomas Jefferson National Accelerator Facility which are operated under contracts DESC0012704 and DE-AC05-06OR23177 respectivel
Recommended from our members
AI-assisted optimization of the ECCE tracking system at the Electron Ion Collider
arXiv preprint [v2] Fri, 20 May 2022 03:23:44 UTC (2,296 KB) made available under a Creative Commons (CC BY) Attribution Licence, now in press, published by Elsevier: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, available online 17 November 2022 at: https://doi.org/10.1016/j.nima.2022.167748The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.Office of Nuclear Physics in the Office of Science in the Department of Energy; National Science Foundation, and the Los Alamos National Laboratory Laboratory Directed Research and Development (LDRD) 20200022DR
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented