43 research outputs found

    Development of potency, breadth and resilience to viral escape mutations in SARS-CoV-2 neutralizing antibodies [preprint]

    Get PDF
    Antibodies elicited in response to infection undergo somatic mutation in germinal centers that can result in higher affinity for the cognate antigen. To determine the effects of somatic mutation on the properties of SARS-CoV-2 spike receptor-binding domain (RBD)-specific antibodies, we analyzed six independent antibody lineages. As well as increased neutralization potency, antibody evolution changed pathways for acquisition of resistance and, in some cases, restricted the range of neutralization escape options. For some antibodies, maturation apparently imposed a requirement for multiple spike mutations to enable escape. For certain antibody lineages, maturation enabled neutralization of circulating SARS-CoV-2 variants of concern and heterologous sarbecoviruses. Antibody-antigen structures revealed that these properties resulted from substitutions that allowed additional variability at the interface with the RBD. These findings suggest that increasing antibody diversity through prolonged or repeated antigen exposure may improve protection against diversifying SARS-CoV-2 populations, and perhaps against other pandemic threat coronaviruses

    Evaluation of SARS-CoV-2 antibody point of care devices in the laboratory and clinical setting

    Get PDF
    SARS-CoV-2 antibody tests have been marketed to diagnose previous SARS-CoV-2 infection and as a test of immune status. There is a lack of evidence on the performance and clinical utility of these tests. We aimed to carry out an evaluation of 14 point of care (POC) SARS-CoV-2 antibody tests. Serum from participants with previous RT-PCR (real-time polymerase chain reaction) confirmed SARS-CoV-2 infection and pre-pandemic serum controls were used to determine specificity and sensitivity of each POC device. Changes in sensitivity with increasing time from infection were determined on a cohort of study participants. Corresponding neutralising antibody status was measured to establish whether the detection of antibodies by the POC device correlated with immune status. Paired capillary and serum samples were collected to ascertain whether POC devices performed comparably on capillary samples. Sensitivity and specificity varied between the POC devices and in general did not meet the manufacturers’ reported performance characteristics, which signifies the importance of independent evaluation of these tests. The sensitivity peaked at ≥20 days following onset of symptoms, however sensitivity of 3 of the POC devices evaluated at extended time points showed that sensitivity declined with time. This was particularly marked at >140 days post infection. This is relevant if the tests are to be used for sero-prevalence studies. Neutralising antibody data showed that positive antibody results on POC devices did not necessarily confer high neutralising antibody titres, and that these POC devices cannot be used to determine immune status to the SARS-CoV-2 virus. Comparison of paired serum and capillary results showed that there was a decline in sensitivity using capillary blood. This has implications in the utility of the tests as they are designed to be used on capillary blood by the general population

    Comparison of SARS-CoV-2 serological assays for use in epidemiological surveillance in Scotland

    Get PDF
    Background: Sero-surveillance of SARS-CoV-2 is crucial to monitoring levels of population exposure and informing public health responses, but may be influenced by variability in performance between available assays. Methods: Five commercial immunoassays and a neutralising activity assay were used to detect antibodies to SARS-CoV-2 in routine primary care and paediatric samples collected during the first wave of the pandemic in NHS Lothian, Scotland as part of ongoing surveillance efforts. For each assay, sensitivity and specificity was calculated relative to consensus results (majority of immunoassays positive = overall positive) and neutralising activity. Quantitative correlation was performed between serological and neutralising titres. Results: Seroprevalence ranged from 3.4–7.3 % in primary care patients and 3–5.9 % in paediatric patients according to different immunoassays. Neutralising activity was detectable in 2.8 % and 1.3 % respectively. Relative assay performance changed depending on comparison to immunoassay consensus versus neutralising activity and qualititative versus quantitative agreement. Cross-reactivity with endemic seasonal coronaviruses was confirmed by neutralising assay in false positives for one immunoassay. Presence of false positives for another assay was found specifically in paediatric but not adult samples. Conclusions: Five serological assays show variable accuracy when applied to the general population, impacting seroprevalence estimates. Assay performance may also vary in detection of protective neutralising antibody levels. These aspects should be considered in assay selection and interpretation in epidemiological studies

    Longitudinal variation in SARS-CoV-2 antibody levels and emergence of viral variants:a serological analysis

    Get PDF
    BACKGROUND: Serological assays are being used to monitor antibody responses in individuals who had SARS-CoV-2 infection and those who received a COVID-19 vaccine. We aimed to determine whether such assays can predict neutralising antibody titres as antibody levels wane and viral variants emerge. METHODS: We measured antibody levels in serum samples from a cohort of 112 participants with SARS-CoV-2 infection using ten high-throughput serological tests and functional neutralisation assays. Serum samples were taken at baseline and at up to four subsequent visits. We assessed the effects of time and spike protein sequence variation on the performance and predictive value of the various assays. We did correlation analyses for individual timepoints using non-parametric Spearman correlation, and differences between timepoints were determined by use of a two-tailed Wilcoxon matched-pairs signed rank test. FINDINGS: Neutralising antibody titres decreased over the first few months post-infection but stabilised thereafter, at about 30% of the level observed shortly after infection. Serological assays commonly used to measure antibodies against SARS-CoV-2 displayed a range of sensitivities that declined to varying extents over time. Quantitative measurements generated by serological assays based on the spike protein were better at predicting neutralising antibody titres than those based on nucleocapsid, but performance was variable, and manufacturer positivity thresholds were not able to predict the presence or absence of detectable neutralising activity. Although we observed some deterioration in correlation between serological measurements and functional neutralisation activity, some assays maintained an ability to predict neutralising titres, even against variants of concern. INTERPRETATION: The ability of high-throughput serological assays to predict neutralising antibody titres is likely to be crucial for evaluation of immunity at the population scale. These data can facilitate the selection of the most suitable assays as surrogates of functional neutralising activity and suggest that such measurements might be useful in clinical practice. FUNDING: US National Institutes of Health and National Health Service Research Scotland BioResource

    Broad cross-reactivity across sarbecoviruses exhibited by a subset of COVID-19 donor-derived neutralizing antibodies

    Get PDF
    Many anti-SARS-CoV-2 neutralizing antibodies target the ACE2-binding site on viral spike receptor-binding domains (RBDs). The most potent antibodies recognize exposed variable epitopes, often rendering them ineffective against other sarbecoviruses and SARS-CoV-2 variants. Class 4 anti-RBD antibodies against a less-exposed, but more-conserved, cryptic epitope could recognize newly-emergent zoonotic sarbecoviruses and variants, but usually show only weak neutralization potencies. We characterized two class 4 anti-RBD antibodies derived from COVID-19 donors that exhibited broad recognition and potent neutralization of zoonotic coronavirus and SARS-CoV-2 variants. C118-RBD and C022-RBD structures revealed CDRH3 mainchain H-bond interactions that extended an RBD β-sheet, thus reducing sensitivity to RBD sidechain changes, and epitopes that extended from the cryptic epitope to occlude ACE2 binding. A C118-spike trimer structure revealed rotated RBDs to allow cryptic epitope access and the potential for intra-spike crosslinking to increase avidity. These studies facilitate vaccine design and illustrate potential advantages of class 4 RBD-binding antibody therapeutics

    Mutational escape from the polyclonal antibody response to SARS-CoV-2 infection is largely shaped by a single class of antibodies

    Get PDF
    Monoclonal antibodies targeting a variety of epitopes have been isolated from individuals previously infected with SARS-CoV-2, but the relative contributions of these different antibody classes to the polyclonal response remains unclear. Here we use a yeast-display system to map all mutations to the viral spike receptor-binding domain (RBD) that escape binding by representatives of three potently neutralizing classes of anti-RBD antibodies with high-resolution structures. We compare the antibody-escape maps to similar maps for convalescent polyclonal plasma, including plasma from individuals from whom some of the antibodies were isolated. The plasma-escape maps most closely resemble those of a single class of antibodies that target an epitope on the RBD that includes site E484. Therefore, although the human immune system can produce antibodies that target diverse RBD epitopes, in practice the polyclonal response to infection is dominated by a single class of antibodies targeting an epitope that is already undergoing rapid evolution

    Structures of Human Antibodies Bound to SARS-CoV-2 Spike Reveal Common Epitopes and Recurrent Features of Antibodies

    Get PDF
    Neutralizing antibody responses to coronaviruses mainly target the receptor-binding domain (RBD) of the trimeric spike. Here, we characterized polyclonal IgGs and Fabs from COVID-19 convalescent individuals for recognition of coronavirus spikes. Plasma IgGs differed in their focus on RBD epitopes, recognition of alpha- and beta-coronaviruses, and contributions of avidity to increased binding/neutralization of IgGs over Fabs. Using electron microscopy, we examined specificities of polyclonal plasma Fabs, revealing recognition of both S1^A and RBD epitopes on SARS-CoV-2 spike. Moreover, a 3.4Ă… cryo-EM structure of a neutralizing monoclonal Fab-spike complex revealed an epitope that blocks ACE2 receptor binding. Modeling based on these structures suggested different potentials for inter-spike crosslinking by IgGs on viruses and that characterized IgGs would not be affected by identified SARS-CoV-2 spike mutations. Overall, our studies structurally define a recurrent anti-SARS-CoV-2 antibody class derived from VH3-53/VH3-66 and similarity to a SARS-CoV VH3-30 antibody, providing criteria for evaluating vaccine-elicited antibodies
    corecore