1,388 research outputs found

    Parathyroidectomy in ESRD

    Get PDF

    EMAT/Synthetic Aperture Approach to Thick-Weld Inspection

    Get PDF
    Rapid advances in automated welding and increased demands for reliable weld-quality inspection tools have created a need for new ultrasonic inspection systems. In particular, new systems capable of operation at elevated temperatures and rapid scan rates are in demand in fully and semi-automated welding applications to complement radiographic and conventional ultrasonic inspection techniques. In such applications, radiography is fundamentally limited because of its inability to detect and dimension most sharp flaws, and possible health hazards. On the other hand, conventional ultrasonic techniques are limited because they tend to be difficult to automate, require fluid couplants, and are often operator-dependent

    Imaging Radiation Pneumonitis in a Rat Model of a Radiological Terrorism Incident

    Get PDF
    We have developed a rat model of single, sub-lethal thoracic irradiation. Our irradiation protocol is considered representative of exposures near the detonation site of a dirty bomb or small nuclear device. The model is being used to investigate techniques for identifying, triaging and treating possible victims. In addition to physiological markers of right ventricular hypertrophy, pulmonary vascular resistance, and arterial distensibility, we present two methods for quantifying microvascular density. We used methods including microfocal X-ray imaging to investigate changes in lung structure/function resulting from radiation exposure. Radiation pneumonitis is a complication in subjects receiving thoracic irradiation. A radiographic hallmark of acute radiation pneumonitis is a diffuse infiltrate corresponding to the radiation treatment field. We describe two methods for quantifying small artery dropout that occurs in the model at the same time-period. Rats were examined 3-days, 2-weeks, 1-month (m), 2-m, 5-m, and 12-m post-irradiation and compared with aged-matched controls. Right ventricular hypertrophy and increases in pulmonary vascular resistance were present during the pneumonitis phase. Vascular injury was dependent on dose and post-irradiation duration. Rats irradiated with 5 Gy had few detectable changes, whereas 10 Gy resulted in a significant decrease in both microvascular density and arterial distensibility around 2- m, the decrease in each lessening, but extending through 12-m. In conclusion, rats irradiated with a 10 Gy dose had changes in vascular structure concurrent with the onset of radiation pneumonitis that were detectable with our imaging techniques and these structural changes persist after resolution of the pneumonitis

    Mitigation of Radiation Induced Pulmonary Vascular Injury by Delayed Treatment with Captopril

    Get PDF
    Background and Objective: A single dose of 10 Gy radiation to the thorax of rats results in decreased total lung angiotensin-converting enzyme (ACE) activity, pulmonary artery distensibility and distal vascular density while increasing pulmonary vascular resistance (PVR) at 2 months post-exposure. In this study, we evaluate the potential of a renin-angiotensin system (RAS) modulator, the ACE inhibitor captopril, to mitigate this pulmonary vascular damage. Methods: Rats exposed to 10 Gy thorax only irradiation and age-matched controls were studied 2 months after exposure, during the development of radiation pneumonitis. Rats were treated, either immediately or 2 weeks after radiation exposure, with two doses of the ACE inhibitor, captopril, dissolved in their drinking water. To determine pulmonary vascular responses, we measured pulmonary haemodynamics, lung ACE activity, pulmonary arterial distensibility and peripheral vessel density. Results: Captopril, given at a vasoactive, but not a lower dose, mitigated radiation-induced pulmonary vascular injury. More importantly, these beneficial effects were observed even if drug therapy was delayed for up to 2 weeks after exposure. Conclusions: Captopril resulted in a reduction in pulmonary vascular injury that supports its use as a radiomitigator after an unexpected radiological event such as a nuclear accident

    Standard Flaws for Eddy Current Probe Characterization

    Get PDF
    Calibration procedures for eddy current inspections often involve the use of artifact standards containing manufactured flaws. The manufactured flaw is assumed to be a good approximation of the type of flaw being sought during the inspection. These manufactured flaws are most often produced by electrical discharge machining (EDM), milling, or the controlled growth of fatigue cracks. With simple amplitude display inspection equipment this type of artifact is usually sufficient, but as more sophisticated inspection equipment is developed some drawbacks to the commonly accepted practice are becoming evident. Instruments that are sensitive to eddy current signal phase as well as amplitude can show considerable differences in phase between a relatively wide EDM notch or milled slot and a real fatigue crack [1]. The use of controlled growth fatigue cracks can also cause problems when forces at the crack’s tip drive the crack faces together, making electrical contact [2], In addition, estimates of crack depth will always be estimates until the crack is broken apart. We describe here a technique for consistently producing well characterized discontinuities in aluminum which are not subject to these problems

    Vascular Injury After Whole Thoracic X-Ray Irradiation in the Rat

    Get PDF
    Purpose To study vascular injury after whole thoracic irradiation with single sublethal doses of X-rays in the rat and to develop markers that might predict the severity of injury. Methods and Materials Rats that received 5- or 10-Gy thorax-only irradiation and age-matched controls were studied at 3 days, 2 weeks, and 1, 2, 5, and 12 months. Several pulmonary vascular parameters were evaluated, including hemodynamics, vessel density, total lung angiotensin-converting enzyme activity, and right ventricular hypertrophy. Results By 1 month, the rats in the 10-Gy group had pulmonary vascular dropout, right ventricular hypertrophy, increased pulmonary vascular resistance, increased dry lung weights, and decreases in total lung angiotensin-converting enzyme activity, as well as pulmonary artery distensibility. In contrast, irradiation with 5 Gy resulted in only a modest increase in right ventricular weight and a reduction in lung angiotensin-converting enzyme activity. Conclusion In a previous investigation using the same model, we observed that recovery from radiation-induced attenuation of pulmonary vascular reactivity occurred. In the present study, we report that deterioration results in several vascular parameters for ≤1 year after 10 Gy, suggesting sustained remodeling of the pulmonary vasculature. Our data support clinically relevant injuries that appear in a time- and dose-related manner after exposure to relatively low radiation doses

    Electron Conditioning of Technical Aluminium Surfaces: Effect on the Secondary Electron Yield

    Full text link
    The effect of electron conditioning on commercially aluminium alloys 1100 and 6063 were investigated. Contrary to the assumption that electron conditioning, if performed long enough, can reduce and stabilize the SEY to low values (≤1.3\leq 1.3, value of many pure elements), the SEY of aluminium did not go lower than 1.8. In fact, it reincreases with continued electron exposure dose.Comment: 36 pages, 25 figures, submitted to JVST

    Salen Mn Complexes Mitigate Radiation Injury in Normal Tissues

    Get PDF
    Salen Mn complexes, including EUK-134, EUK-189 and a newer cyclized analog EUK-207, are synthetic SOD/catalase mimetics that have beneficial effects in many models of oxidative stress. As oxidative stress is implicated in some forms of delayed radiation injury, we are investigating whether these compounds can mitigate injury to normal tissues caused by ionizing radiation. This review describes some of this research, focusing on several tissues of therapeutic interest, namely kidney, lung, skin, and oral mucosa. These studies have demonstrated suppression of delayed radiation injury in animals treated with EUK-189 and/or EUK-207. While an antioxidant mechanism of action is postulated, it is likely that the mechanisms of radiation mitigation by these compounds in vivo are complex and may differ in the various target tissues. Indicators of oxidative stress are increased in lung and skin radiation injury models, and suppressed by salen Mn complexes. The role of oxidative stress in the renal injury model is unclear, though EUK-207 does mitigate. In certain experimental models, salen Mn complexes have shown “mito-protective” properties, that is, attenuating mitochondrial injury. Consistent with this, EUK-134 suppresses effects of ionizing radiation on mitochondrial function in rat astrocyte cultures. In summary, salen Mn complexes could be useful to mitigate delayed radiation injury to normal tissues following radiation therapy, accidental exposure, or radiological terrorism. Optimization of their mode of delivery and other key pharmaceutical properties, and increasing understanding of their mechanism(s) of action as radiation mitigators, are key issues for future study
    • …
    corecore