27 research outputs found
The James Webb Space Telescope Mission: Optical Telescope Element Design, Development, and Performance
The James Webb Space Telescope (JWST) is a large, infrared space telescope
that has recently started its science program which will enable breakthroughs
in astrophysics and planetary science. Notably, JWST will provide the very
first observations of the earliest luminous objects in the Universe and start a
new era of exoplanet atmospheric characterization. This transformative science
is enabled by a 6.6 m telescope that is passively cooled with a 5-layer
sunshield. The primary mirror is comprised of 18 controllable, low areal
density hexagonal segments, that were aligned and phased relative to each other
in orbit using innovative image-based wavefront sensing and control algorithms.
This revolutionary telescope took more than two decades to develop with a
widely distributed team across engineering disciplines. We present an overview
of the telescope requirements, architecture, development, superb on-orbit
performance, and lessons learned. JWST successfully demonstrates a segmented
aperture space telescope and establishes a path to building even larger space
telescopes.Comment: accepted by PASP for JWST Overview Special Issue; 34 pages, 25
figure
The James Webb Space Telescope Mission
Twenty-six years ago a small committee report, building on earlier studies,
expounded a compelling and poetic vision for the future of astronomy, calling
for an infrared-optimized space telescope with an aperture of at least .
With the support of their governments in the US, Europe, and Canada, 20,000
people realized that vision as the James Webb Space Telescope. A
generation of astronomers will celebrate their accomplishments for the life of
the mission, potentially as long as 20 years, and beyond. This report and the
scientific discoveries that follow are extended thank-you notes to the 20,000
team members. The telescope is working perfectly, with much better image
quality than expected. In this and accompanying papers, we give a brief
history, describe the observatory, outline its objectives and current observing
program, and discuss the inventions and people who made it possible. We cite
detailed reports on the design and the measured performance on orbit.Comment: Accepted by PASP for the special issue on The James Webb Space
Telescope Overview, 29 pages, 4 figure
Promise of combined hydrothermal/chemical and mechanical refining for pretreatment of woody and herbaceous biomass
Fabrication and characterization of polymer microfluidic devices for BioAgent detection
Sandia and Lawrence Livermore National Laboratories are developing a briefcase-sized, broad-spectrum bioagent detection system. This autonomous instrument, the BioBriefcase, will monitor the environment and warn against bacterium, virus, and toxin based biological attacks. At the heart of this device, inexpensive polymer microfluidic chips will carry out sample preparation and analysis. Fabrication of polymer microfluidic chips involves the creation of a master in etched glass; plating of the master to produce a nickel stamp; large lot chip replication by injection molding; and thermal chip sealing. Since the performance and reliability of microfluidic chips are very sensitive to fluidic impedance and to electromagnetic fluxes, the microchannel dimensions and shape have to be tightly controlled during chip fabrication. In this talk, we will present an overview of chip design and fabrication. Metrology data collected at different fabrication steps and the dimensional deviations of the polymer chip from the original design will be discussed
Autonomous Microfluidic Sample Preparation System for Protein Profile-Based Detection of Aerosolized Bacterial Cells and Spores
Injection molded microfluidic devices for biological sample separation and detection
We are developing a variety of microsystems for the separation and detection of biological samples. At the heart of these systems, inexpensive polymer microfluidic chips carry out sample preparation and analysis. Fabrication of polymer microfluidic chips involves the creation of a master in etched silicon or glass; plating of the master to produce a nickel stamp; large lot chip replication by injection molding; precision chip sealing; and chemical modification of channel surfaces. Separation chips rely on insulator-based dielectrophoresis for the separation of biological particles. Detection chips carry out capillary electrophoresis to detect fluorescent tags that identify specific biological samples. Since the performance and reliability of these microfluidic chips are very sensitive to fluidic impedance, electromagnetic flux, and zeta potential, the microchannel dimensions, shape, and surface chemistry have to be tightly controlled during chip fabrication and use. This paper will present an overview of chip design, fabrication, and testing. Dimensional metrology data, surface chemistry characterization, and chip performance data will be discussed in detail