237 research outputs found

    The γ-rays sky with the AMS-02 electromagnetic calorimeter

    Get PDF
    The Alpha Magnetic Spectrometer (AMS-02) is a multipurpose astroparticle physics detector installed since May 2011 as an external module on the International Space Station (ISS). AMS-02 orbits at an altitude of about 430km for measuring with an unprecedented accuracy the flux and composition of primary cosmic rays in the GeV-TeV energy range, searching for primordial Anti-Matter and probing the nature of Dark Matter. Despite the fact that AMS-02 is designed primarly as a charged-particle detector, it is also an instrument able to perform precision observations of γ-rays. The key sub-detector in the photon identification and reconstruction is the e.m. calorimeter that, besides having an excellent energy resolution, can also provide the direction of the incoming particle. In this paper the AMS-02 γ-rays sky obtained with the first 22 months of data is presented

    Components Qualification for a Possible use in the Mu2e Calorimeter Waveform Digitizers

    Full text link
    The Mu2e experiment at Fermilab searches for the charged flavor violating conversion of a muon into an electron in the Coulomb field of a nucleus. The detector consists of a straw tube tracker and a CSI crystal electromagnetic calorimeter, both housed in a superconducting solenoid. Both the front-end and the digital electronics, located inside the cryostat, will be operated in vacuum under a 1 T magnetic field, having to sustain the high flux of neutrons and ionizing particles coming from the muons stopping target. These harsh experimental conditions make the design of the calorimeter waveform digitizer quite challenging. All the selected commercial devices must be tested individually and qualified for radiation hardness and operation in high magnetic field. At the moment the expected particles flux and spectra at the digitizers location are not completely simulated and we are using initial rough estimates to select the components for the first prototype. We are gaining experience in the qualification procedures using the selected components but the choice will be frozen only when dose and neutron flux simulations will be completed. The experimental results of the first qualification campaign are presented.Comment: TWEPP 2016 - Topical Workshop on Electronics for Particle Physics, 26-30 September 2016, Karlsruhe Institute of Technology (KIT

    Observation of high-energy gamma-rays with the AMS-02 electromagnetic calorimeter

    Get PDF
    The Alpha Magnetic Spectrometer (AMS-02) is a multipurpose astroparticle physics detector installed on the International Space Station (ISS). Since more than 5 years it is measuring with an unprecedented accuracy flux and composition of primary cosmic rays, searching for primordial anti-matter and probing the nature of dark matter. Despite the fact that AMS-02 has been primarily designed as a charged-particle spectrometer, it can also perform precision observations of γ-rays from a few GeV to beyond one TeV. The key sub-detector used for the photon identification is a lead-scintillating fibers sampling calorimeter (ECAL). Its high granularity allows to reconstruct the direction of the incoming photon with a resolution better than 1 degree. The 3D shower image reconstructed by the calorimeter together with the absence of hits along the reconstructed photon direction allow to reach a very good signal over background ratio. This experimental technique offers the unusual possibility to reconstruct a sky map of the very high-energy photon sources

    Design, status and perspective of the Mu2e crystal calorimeter

    Full text link
    The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less μe\mu \to e coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about 2.510172.5\cdot 10^{-17} that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform μ\mu/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R&\&D results.Comment: 4 pages, conference proceeding for a presentation held at TIPP'2017. To be published on Springer Proceedings in Physic

    Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers

    Full text link
    The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for \sim100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3×\times2 array of 6×\times6 mm2^2 UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to \sim8.5~×\times~1011^{11} 1 MeV (Si) eq. n/cm2^{2} and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than \sim106^{6} hours.Comment: NDIP 2017 - New Developments In Photodetection, 3-7 July 2017, Tours (France

    Energy and time resolution for a LYSO matrix prototype of the Mu2e experiment

    Full text link
    We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60-450 MeV. This study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.Comment: 2 pages, 3 figures, 13th Pisa Meeting on Advanced Detector

    Quality Assurance on a custom SiPMs array for the Mu2e experiment

    Full text link
    The Mu2e experiment at Fermilab will search for the coherent μe\mu \to e conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.Comment: 4 pages, 10 figures, conference proceeding for NSS-MIC 201

    The Mu2e undoped CsI crystal calorimeter

    Full text link
    The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.Comment: 6 pages, 8 figures, proceedings of the "Calorimetry for the high energy frontier (CHEF17)" conference, 2-6 October 2017, Lyon, Franc
    corecore