435 research outputs found

    Risks and Benefits of Catheter Ablation of Ventricular Tachycardia in Patients With an Implantable Cardioverter-Defibrillators

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/44660/1/10572_2004_Article_202518.pd

    Risks and Benefits of Catheter Ablation of Ventricular Tachycardia in Patients with an Implantable Cardioverter-Defibrillator

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/44675/1/10572_2004_Article_321357.pd

    Effects of different packaging methods on microbial, [chemical] and sensory properties of Nile tilapia (Oreochromis niloticus Linnaeus, 1758) fillets during refrigerator storage

    Get PDF
    The effect of three different packaging methods including Modified Atmosphere Packaging (MAP), Vacuum Packaging and normal Packaging was investigated on the quality of Nile tilapia fresh fillets stored in the refrigerator's temperature. The packaged samples were examined for 10 days with regard to the changes in chemical (TVN, PV, pH), microbial (total viable count) and sensory evaluations. The results indicated that the samples packed in MAP condition had higher quality than that of other methods at the end of the storage period. In addition, the slower destructive impacts and microbial growth was observed in MAP. The results of present study suggest that packaging tilapia under MAP conditions results in the increase in the durability, storing, and distribution period for fillets

    Interaction Between Autonomic Tone and the Negative Chronotropic Effect of Adenosine in Humans

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72287/1/j.1540-8159.1999.tb00412.x.pd

    Diagnostic value of tachycardia features and pacing maneuvers during paroxysmal supraventricular tachycardia

    Get PDF
    AbstractOBJECTIVESThe purpose of this prospective study was to quantitate the diagnostic value of several tachycardia features and pacing maneuvers in patients with paroxysmal supraventricular tachycardia (PSVT) in the electrophysiology laboratory.BACKGROUNDNo study has prospectively compared the value of multiple diagnostic tools in a large group of patients with PSVT.METHODSOne hundred ninety-six consecutive patients who had 200 inducible sustained PSVTs during an electrophysiology procedure were included. The diagnostic values of four baseline electrophysiologic parameters, nine tachycardia features and five diagnostic pacing maneuvers were quantified.RESULTSThe only tachycardia characteristic that was diagnostic of atrioventricular (AV) nodal reentry was a septal ventriculoatrial (VA) time of <70 ms, and no pacing maneuver was diagnostic for AV nodal reentry. An increase in the VA interval with the development of a bundle branch block was the only tachycardia characteristic that was diagnostic for orthodromic tachycardia, but it occurred in only 7% of all tachycardias. An atrial-atrial-ventricular response upon cessation of ventricular overdrive pacing was diagnostic of atrial tachycardia, and this maneuver could be applied to 78% of all tachycardias. Burst ventricular pacing excluded atrial tachycardia when the tachycardia terminated without depolarization of the atrium, but the result could be obtained only in 27% of patients.CONCLUSIONSThis prospective study quantitates the diagnostic value of multiple observations and pacing maneuvers that are commonly used during PSVT in the electrophysiology laboratory. The findings demonstrate that diagnostic techniques rarely provide a diagnosis when used individually. Therefore, careful observations and multiple pacing maneuvers are often required for an accurate diagnosis during PSVT. The results of this study provide a useful reference with which new diagnostic techniques can be compared
    • …
    corecore