6 research outputs found

    Real-ear-to-coupler difference predictions as a function of age for two coupling procedures

    No full text
    The predicted real-ear-to-coupler difference (RECD) values currently used in pediatric hearing instrument prescription methods are based on 12-month age range categories and were derived from measures using standard acoustic immittance probe tips. Consequently, the purpose of this study was to develop normative RECD predicted values for foam/acoustic immittance tips and custom earmolds across the age continuum. To this end, RECD data were collected on 392 infants and children (141 with acoustic immittance tips, 251 with earmolds) to develop normative regression equations for use in deriving continuous age predictions of RECDs for foam/acoustic immittance tips and earmolds. Owing to the substantial between-subject variability observed in the data, the predictive equations of RECDs by age (in months) resulted in only gross estimates of RECD values (i.e., within +/- 4.4 dB for 95% of acoustic immittance tip measures; within +/- 5.4 dB in 95% of measures with custom earmolds) across frequency. Thus, it is concluded that the estimates derived from this study should not be used to replace the more precise individual RECD measurements. Relative to previously available normative RECD values for infants and young children, however, the estimates derived through this study provide somewhat more accurate predicted values for use under those circumstances for which individual RECD measurements cannot be made

    Using the real-ear-to-coupler difference within the American Academy of audiology pediatric amplification guideline: Protocols for applying and predicting earmold RECDs

    No full text
    Background: Real-ear-to-coupler difference (RECD) measurements are used for the purposes of estimating degree and configuration of hearing loss (in dB SPL ear canal) and predicting hearing aid output from coupler-based measures. Accurate measurements of hearing threshold, derivation of hearing aid fitting targets, and predictions of hearing aid output in the ear canal assume consistent matching of RECD coupling procedure (i.e., foam tip or earmold) with that used during assessment and in verification of the hearing aid fitting. When there is a mismatch between these coupling procedures, errors are introduced. Purpose: The goal of this study was to quantify the systematic difference in measured RECD values obtained when using a foam tip versus an earmold with various tube lengths. Assuming that systematic errors exist, the second goal was to investigate the use of a foam tip to earmold correction for the purposes of improving fitting accuracy when mismatched RECD coupling conditions occur (e.g., foam tip at assessment, earmold at verification). Study Sample: Eighteen adults and 17 children (age range: 3-127 mo) participated in this study. Data Collection and Analysis: Data were obtained using simulated ears of various volumes and earmold tubing lengths and from patients using their own earmolds. Derived RECD values based on simulated ear measurements were compared with RECD values obtained for adult and pediatric ears for foam tip and earmold coupling. Results: Results indicate that differences between foam tip and earmold RECDs are consistent across test ears for adults and children which support the development of a correction between foam tip and earmold couplings for RECDs that can be applied across individuals. Conclusions: The foam tip to earmold correction values developed in this study can be used to provide improved estimations of earmold RECDs. This may support better accuracy in acoustic transforms related to transforming thresholds and/or hearing aid coupler responses to ear canal sound pressure level for the purposes of fitting behind-the-ear hearing AIDS

    Ultraviolet spectrometry

    No full text
    corecore