7 research outputs found

    Added Value of CCTA-Derived Features to Predict MACEs in Stable Patients Undergoing Coronary Computed Tomography

    Get PDF
    Clinical evidence has emphasized the importance of coronary plaques' characteristics, rather than lumen stenosis, for the outcome of cardiovascular events. Coronary computed tomographic angiography (CCTA) has a well-established role as a non-invasive tool for assessing plaques. The aim of this study was to compare clinical characteristics and CCTA-derived information of stable patients with non-severe plaques in predicting major adverse cardiac events (MACEs) during follow-up. We retrospectively selected 371 patients (64% male) who underwent CCTA in our center from March 2016 to January 2021 with Coronary Artery Disease-Reporting and Data System (CAD-RADS) 0 to 3. Of those, 198 patients (53% male) had CAD-RADS 0 to 1. Among them, 183 (49%) had normal pericoronary fat attenuation index (pFAI), while 15 (60% male) had pFAI ≥ 70.1 Hounsfield unit (HU). The remaining 173 patients (76% male) had CAD-RADS 2 to 3 and were divided into patients with at least one low attenuation plaque (LAP) and patients without LAPs (n-LAP). Compared to n-LAP, patients with LAPs had higher pFAI (p = 0.005) and had more plaques than patients with n-LAP. Presence of LAPs was significantly higher in elderly (p < 0.001), males (p < 0.001) and patients with traditional risk factors (hypertension p = 0.0001, hyperlipemia p = 0.0003, smoking p = 0.0003, diabetes p = <0.0001, familiarity p = 0.0007). Among patients with CAD-RADS 0 to 1, the ones with pFAI ≥ 70.1 HU were more often hyperlipidemic (p = 0.05) and smokers (p = 0.007). Follow-up (25,4 months, range: 17.6-39.2 months) demonstrated that LAP and pFAI ≥ 70.1 significantly and independently (p = 0.04) predisposed to outcomes (overall mortality and interventional procedures). There is an added value of CCTA-derived features in stratifying cardiovascular risk in low- to intermediate-risk patients with non-severe, non-calcified coronary plaques. This is of utmost clinical relevance as it is possible to identify a subset of patients with increased risk who need strengthening in therapeutic management and closer follow-up even in the absence of severe CAD. Further studies are needed to evaluate the effect of medical treatments on pericoronary inflammation and plaque composition

    Coronary Access After Transcatheter Aortic Valve Replacement With Commissural Alignment: The ALIGN-ACCESS Study

    No full text
    Background: Coronary access (CA) after transcatheter aortic valve replacement (TAVR) with supra-annular transcatheter heart valves (THV) can be challenging. Specific Evolut R/Pro and Acurate Neo THVs orientations are associated with reduced neo-commissure overlap with coronary ostia, while SAPIEN 3 THV cannot be oriented. With the ALIGN-ACCESS study (TAVR With Commissural Alignment Followed by Coronary Access), we investigated the impact of commissural alignment on the feasibility of CA after TAVR. Methods: We performed coronary angiography after TAVR with intra-annular SAPIEN 3, supra-annular Evolut R/Pro, and Acurate Neo THVs in 206 patients. Evolut THVs were implanted aiming for commissure alignment. Alignment of Acurate Neo was retrospectively assessed in 36, intentionally attempted in 26 cases. The primary end point was the rate of unfeasible and nonselective CA after TAVR. Results: Thirty-eight percent of patients received SAPIEN 3, 31.1% Evolut Pro/R, 30.1% Acurate Neo THV. Final valve orientation was favorable to commissural alignment in 85.9% of Evolut and 69.4% of Acurate Neo cases (with intentional alignment successful in 88.5%). Selective CA was higher for SAPIEN 3 than for aligned and misaligned supra-annular THVs (95% versus 71% versus 46%, P<0.001). Cannulation of at least one coronary was unfeasible with 11% misaligned supra-annular, 3% aligned supra-annular, and 0% SAPIEN 3 THVs. Independent predictors of unfeasible/nonselective CA were implantation of a misaligned supra-annular THV (odds ratio, 4.59 [95% CI, 1.81-11.61]; P<0.01), sinus of Valsalva height (odds ratio, 0.83 [95% CI, 0.7-0.98]; P=0.03), and THV-sinus of Valsalva relation (odds ratio, 1.06 [95% CI, 1.02-1.1]; P<0.01). Conclusions: Commissural alignment improves the rate of selective CA after TAVR with supra-annular THVs. Nevertheless, aligned supra-annular THVs carry higher risk of unfeasible/nonselective CA than SAPIEN 3. Patients with a misaligned supra-annular THV, low sinus of Valsalva, and higher THV-sinus of Valsalva relation are at highest risk of impaired CA after TAVR

    Definition of trAnscatheter heart Valve orIeNtation in biCuspId aortic valve: The DA VINCI pilot study

    No full text
    ObjectivesTo assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). BackgroundSpecific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. MethodsThe DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40 degrees between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. ResultsThirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. ConclusionGiven cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients

    Real-World Experience With a Large Bore Vascular Closure Device During TAVI Procedure: Features and Predictors of Access-Site Vascular Complications

    No full text
    Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes

    Characteristics and hospital course of patients admitted for acute cardiovascular diseases during the coronavirus disease-19 outbreak

    No full text
    INTRODUCTION: During the coronavirus disease-19 (COVID-19) outbreak in spring 2020, people may have been reluctant to seek medical care fearing infection. We aimed to assess the number, characteristics and in-hospital course of patients admitted for acute cardiovascular diseases during the COVID-19 outbreak.METHODS: We enrolled all consecutive patients admitted urgently for acute myocardial infarction, heart failure or arrhythmias from 1 March to 31 May 2020 (outbreak period) and 2019 (control period). We evaluated the time from symptoms onset to presentation, clinical conditions at admission, length of hospitalization, in-hospital medical procedures and outcome. The combined primary end point included in-hospital death for cardiovascular causes, urgent heart transplant or discharge with a ventricular assist device.RESULTS: A similar number of admissions were observed in 2020 (N\u200a=\u200a210) compared with 2019 (N\u200a=\u200a207). Baseline characteristics of patients were also similar. In 2020, a significantly higher number of patients presented more than 6\u200ah after symptoms onset (57 versus 38%, P\u200a<\u200a0.001) and with signs of heart failure (33 versus 20%, P\u200a=\u200a0.018), required urgent surgery (13 versus 5%, P\u200a=\u200a0.004) and ventilatory support (26 versus 13%, P\u200a<\u200a0.001). Hospitalization duration was longer in 2020 (median 10 versus 8 days, P\u200a=\u200a0.03). The primary end point was met by 19 (9.0%) patients in 2020 versus 10 (4.8%) in 2019 (P\u200a=\u200a0.09).CONCLUSION: Despite the similar number and types of unplanned admissions for acute cardiac conditions during the 2020 COVID-19 outbreak compared with the same period in 2019, we observed a higher number of patients presenting late after symptoms onset as well as longer and more complicated clinical courses

    10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance

    No full text
    BackgroundThe impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. MethodsConsecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. ResultsA total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10-22; SA 11%, 95%CI: 6-20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20-23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. ConclusionIn this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes

    Transcatheter aortic valve replacement with the self-expanding ACURATE Neo2 in patients with horizontal aorta: Insights from the ITAL-neo registry

    No full text
    Background: Horizontal aorta (HA), defined by an aortic angulation (AA) >= 48 degrees, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL).Objectives: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA.Methods: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes.Results: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing >= moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of >= moderate PVL vs. Neo: (5% vs. 15%; p = moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort.Conclusion: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of >= moderate PVL, when compared with its predecessor
    corecore