710 research outputs found

    Full Characterization of the First 1 Inch Industrial Prototype of a New Concept Photodetector

    Full text link
    The VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an original design for an innovative light detector we proposed with the aim to create new scientific instrumentation for industrial applications and physics research. The idea behind this device is to replace the classical dynode chain of a photomultiplier tube with a silicon photomultiplier, the latter acting as an electron detector and amplifier. The VSiPMT offers very attractive features and unprecedented performance, definitely superior to every other photodetector with comparable sensitive surface, such as: negligible power cosumption, excellent photon counting, easy low-voltage-based stabilization and very good time performance. After the feasibility test of the idea, Hamamatsu Photonics realized for our research group two VSiPMT industrial prototypes, that have been fully characterized. The results of the full characterization of the 1-inch industrial prototype are presented in this work.Comment: 11 pages, 14 figure

    A flexible quantum efficiency measurement device for photosensors testing

    Full text link
    This paper presents a new quantum efficiency setup based on a 2D motorized stage, a wide spectrum xenon lamp, a beam splitter system, and two calibrated photodiodes for measuring the quantum efficiency (QE) of photosensors from PMTs (1 to 10 inches) to SIPM and photodiodes. The large area covered by the 2D stages permit to study the quantum efficiency of a matrix of multichannel photosensors in an automated way and PMTs with diameter up to ten inches. The setup offers high precision and accuracy in characterizing the quantum efficiency versus wavelength over the range of 250 nm to 1100 nm and in two dimensions with a positioning precision of ten microns. The setup monitors the light intensity synchronously with the output current yield from photosensors under test. This ensures the accuracy and repeatability of the measurements. The motorized stage allows precise positioning of the light source with respect to the active area. Moreover, the emission spectrum of the xenon lamp provides a broad range of illumination in terms of dynamics and wavelength span

    NASA follow-on to the Bangladesh Agro-Climatic Environmental Monitoring Project

    Get PDF
    The NASA responsibility and activities for the follow-on to the original Agro-Climatic Environmental Monitoring Project (ACEMP) which was completed during 1987 is described. Five training sessions which comprise the NASA ACEMP follow-on are: Agrometeorology, Meteorology of Severe Storms Using GEMPAK, Satellite Oceanography, Hydrology, and Meteorology with TOVS. The objective of the follow-on is to train Bangladesh Government staff in the use of satellite data for remote sensing applications. This activity also encourages the scientific connection between NASA/Goddard Space Flight Center and The Bangladesh Space and Remote Sensing Organization (SPARRSO)

    Clinopyroxene-liquid thermometers and barometers specific to alkaline differentiated magmas

    Get PDF
    We present new thermometers and barometers based on clinopyroxene-liquid equilibria specific to alkaline differentiated magmas. The new models were calibrated through the regression analyses of experimental datasets obtained by merging phase equilibria experiments from the literature with new experiments performed by using trachytic and phonolitic starting compositions. The regression strategy was twofold: (1) we have tested previous thermometric and barometric equations and recalibrated these models using the new datasets; (2) we have calibrated a new thermometer and a new barometer including only regression parameters that closely describe the compositional variability of the datasets. The new models yield more precise estimates than previous thermometers and barometers when used to predict temperatures and pressures of alkaline differentiated magmas. We have tested the reliability of the new equations by using clinopyroxene-liquid pairs from trachytes and phonolites erupted during major explosive eruptions at the Phlegrean Fields and Mt. Vesuvius (central Italy). The test yielded crystallization conditions comparable to those determined by means of melt and fluid inclusion analyses and phase equilibria studies; this validates the use of the proposed models for precise estimates of crystallization temperatures and pressures in differentiated alkaline magmas. Because these magmas feed some of the most voluminous, explosive, and threatening volcanic eruptions in the world, a better understanding of the environmental conditions of their reservoirs is mandatory and this is now possible with the new models provided here. © 2013 Springer-Verlag Berlin Heidelberg

    Pre-service primary teachers’ emotions: the math-redemption phenomenon

    Get PDF

    Study of the stability of a paramagnetic label linked to mesoporous silica surface in contact with rat mesothelial cells in culture.

    Get PDF
    Stable radicals detectable by electron paramagnetic resonance (EPR) may be use in the investigation of early events in cell-particle toxicity. Piperidine-N-oxyl derivatives (nitroxides), covalently linked to the surface of a high surface area silica (used as model solid for the technique), served as probes in the investigation of the effects of incubation of silica particles with mesothelial cells. A mesoporous silica (MCM-41), prepared by precipitation from a micellar solution, was the most appropriate silica-based particle for this purpose, as its channels allow direct contact with small molecules but not with macromolecules. The cytotoxicity of this amorphous silica is very low, allowing relatively high particle loading in the cell cultures. Both the high surface area of the sample and the large amount of inorganic material extracted from the cell culture provide enough material to run reasonably intense EPR spectra. Computer-aided analysis of the EPR spectra of silica-bound nitroxides provided information on the sensitivity of the labeled silica monitoring different environments, e.g., to follow the path of particles in a mammalian cell culture. Upon contact of the particles with mesothelial cells, the mean distance among the labels at the silica surface decreased as a consequence of the release of oxidizing and/or radical moieties from the cells

    Carbonate assimilation in magmas: a reappraisal based on experimental petrology

    Get PDF
    The main effect of magma-carbonate interaction on magma differentiation is the formation of a silica-undersaturated, alkali-rich residual melt. Such a desilication process was explained as the progressive dissolution of CaCO3 in melt by consumption of SiO2 and MgO to form diopside sensu stricto. Magma chambers emplaced in carbonate substrata, however, are generally associated with magmatic skarns containing clinopyroxene with a high Ca-Tschermak activity in their paragenesis. Data are presented from magma-carbonate interaction experiments, demonstrating that carbonate assimilation is a complex process involving more components than so far assumed. Experimental results show that, during carbonate assimilation, a diopside-hedenbergite-Ca-Tschermak clinopyroxene solid solution is formed and that Ca-Tschermak/diopside and hedenbergite/diopside ratios increase as a function of the progressive carbonate assimilation. Accordingly, carbonate assimilation reaction should be written as follows, taking into account all the involved magmatic components: CaCO3solid+SiO2melt+MgOmelt+FeOmelt+Al2O3melt → (Di-Hd-CaTs)sssolid+CO2fluid The texture of experimental products demonstrates that carbonate assimilation produces three-phases (solid, melt, and fluid) whose main products are: i) diopside-hedenbergite-Ca-Tschermak clinopyroxene solid solution; ii) silica-undersaturated CaO-rich melt; and iii) C-O-H fluid phase. The silica undersaturation of the melt and, more importantly, the occurrence of a CO2-rich fluid phase, must be taken into account as they significantly affect partition coefficients and the redox state of carbonated systems, respectively

    A new generation photodetector for astroparticle physics: the VSiPMT

    Get PDF
    The VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an innovative design we proposed for a revolutionary photon detector. The main idea is to replace the classical dynode chain of a PMT with a SiPM (G-APD), the latter acting as an electron detector and amplifier. The aim is to match the large sensitive area of a photocathode with the performance of the SiPM technology. The VSiPMT has many attractive features. In particular, a low power consumption and an excellent photon counting capability. To prove the feasibility of the idea we first tested the performance of a special non-windowed SiPM by Hamamatsu (MPPC) as electron detector and current amplifier. Thanks to this result Hamamatsu realized two VSiPMT industrial prototypes. In this work, we present the results of a full characterization of the VSiPMT prototype

    Fault structure and slip localization in carbonate-bearing normal faults: An example from the Northern Apennines of Italy

    Get PDF
    Carbonate-bearing normal faults are important structures for controlling fluid flow and seismogenesis within the brittle upper crust. Numerous studies have tried to characterize fault zone structure and earthquake slip processes along carbonate-bearing faults. However, due to the different scales of investigation, these studies are not often integrated to provide a comprehensive fault image. Here we present a multi-scale investigation of a normal fault exhumed from seismogenic depths. The fault extends for a length of 10 km with a maximum width of about 1.5 km and consists of 5 sub-parallel and interacting segments. The maximum displacement (370e650 m) of each fault segment is partitioned along sub-parallel slipping zones extending for a total width of about 50 m. Each slipping zone is characterized by slipping surfaces exhibiting different slip plane phenomena. Fault rock development is controlled by the protolith lithology. In massive limestone, moving away from the slip surface, we observe a thin layer (<2 cm) of ultracataclasite, cataclasite (2e10 cm) and fault breccia. In marly limestone, the fault rock consists of a cataclasite with hydrofractures and smectite-rich pressure solution seams. At the micro-nanoscale, the slip surface consists of a continuous and thin (<300 mm) layer composed of coarse calcite grains (~5e20 mm in size) associated with sub-micrometer grains showing fading grain boundaries, voids and/or vesicles, and suggesting thermal decomposition processes. Micrometer-sized calcite crystals show nanoscale polysynthetic twinning affected by the occurrence of subgrain boundaries and polygonalized nanostructures. Investigations at the kilometres-tens of meter scale provide fault images that can be directly compared with high-resolution seismological data and when combined can be used to develop a comprehensive characterization of seismically active fault structures in carbonate lithologies. Micro and nanoscale investigations along the principal slipping zone suggest that different deformation processes, including plastic deformation and thermal decomposition, were active during seismic slip

    The VSiPMT project

    Get PDF
    Photon detection is a key factor to study many physical processes in several areas of fundamental physics research. Focusing the attention on photodetectors for particle astrophysics, the future experiments aimed at the study of very high-energy or extremely rare phenomena (e.g. dark matter, proton decay, neutrinos from astrophysical sources) will require additional improvements in linearity, gain, quantum efficiency and single photon counting capability. To meet the requirements of this class of experiments, we propose a new design for a modern hybrid photodetector: the VSiPMT (Vacuum Silicon PhotoMultiplier Tube). The idea is to replace the classical dynode chain of a PMT with a SiPM, which therefore acts as an electron detector and amplifier. The aim is to match the large sensitive area of a photocathode with the performances of the SiPM technology. We now present the preliminary study we are performing to realize a 3-inches VSiPMT prototype
    • …
    corecore