8 research outputs found

    Comparison of SPECT bone scintigraphy with MRI for diagnosis of meniscal tears

    Get PDF
    BACKGROUND: Scintigraphy has been considered as competitive to MRI, but limited data are available on the accuracy of single photon emission tomography (SPECT) compared with MRI for the assessment of meniscal tears. Our objective was to assess the value of SPECT in comparison to MRI. METHODS: Between January 2003 and March 2004, sixteen patients were studied with both modalities and the accuracy rates of SPECT scan results, and MRI findings in the diagnosis of meniscal tears were compared. Arthroscopy was the gold standard. RESULTS: The respective sensitivity rate, specificity rate, and positive and negative predictive accuracies of MRI were 89%, 94%, 93%, and 79% and for SPECT those were 78%, 94%, 94%, and 88%. There was good agreement on the presence or absence of tears between two modalities (κ statistic = 0.699). CONCLUSION: SPECT and MRI are both valuable imaging techniques. SPECT is a useful alternative when MRI is unavailable or unsuitable and it is beneficial when more possible accuracy is desired (such as when MRI results are either inconclusive or conflict with other clinical data)

    99m tc-Ubiquicidin [29-41], a Promising Radiopharmaceutical to Differentiate Orthopedic Implant Infections from Sterile Inflammation

    No full text
    Abstract Ubiquicidin (UBI) [29][30][31][32][33][34][35][36][37][38][39][40][41] is a synthetic cationic antimicrobial peptide that preferentially binds to bacterial cell membrane at the site of infection. We aimed to assess diagnostic value of Tc-UBI [29-41] was injected intravenously. A dynamic study followed by static whole body imaging at 30, 60 and 120 min post-radiotracer injection was acquired. Periprosthetic tissue culture was considered the closest test to a gold standard for diagnosing infections and scintigraphic scans were categorized as true-or false-positive and true-or false-negative, considering the bacterial culture as the gold standard. No adverse reaction was observed during or after the radiotracer injection days. There were five true positive, four true negative and no false positive and false negative scans. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were all calculated as 100%. We found a high diagnostic accuracy for 99m scintigraphy in differentiation of bacterial infection from sterile inflammation in suspected orthopedic implants. Therefore, Tc-UBI [29][30][31][32][33][34][35][36][37][38][39][40][41] scintigraphy might be potentially recommended as a safe and promising imaging modality in these settings. However, further studies on a larger number of patients and different pathologies are still needed

    Management of tibial nonunion and osteoarthritis using a 3D-printed titanium cone: A case report

    No full text
    The use of customized 3D-printed structures has been gaining popularity in non-union management, as it allows for bypassing the defect while promoting osseointegration. Additionally, porous titanium implants minimize stress shielding due to their stiffness and elastic modulus being closer to that of bone. The interconnected channels increase the surface area and provide space for cell adhesion and proliferation. This study presents the case of a 62-year-old female patient with concomitant knee osteoarthritis recalcitrant aseptic atrophic nonunion in the tibial proximal metaphysis. Due to the small distance between the nonunion site and the joint line, nonunion treatment had to be included in the treatment plan, as it would result in a lack of mechanical stability of the tibial component, and techniques such as plating were not an option. A customized 3D-printed porous titanium cone was used to bypass the fracture site and support the stem used with the CCK prosthesis, allowing for simultaneous nonunion and osteoarthritis management
    corecore