5 research outputs found

    Indoor environment assessment of special wards of educational hospitals for the detection of fungal contamination sources: A multi-center study (2019-2021)

    Get PDF
    Background and Purpose: The hospital environment was reported as a real habitat for different microorganisms, especially mold fungi. On the other hand, these opportunistic fungi were considered hospital-acquired mold infections in patients with weak immune status. Therefore, this multi-center study aimed to evaluate 23 hospitals in 18 provinces of Iran for fungal contamination sources.Materials and Methods: In total, 43 opened Petri plates and 213 surface samples were collected throughout different wards of 23 hospitals. All collected samples were inoculated into Sabouraud Dextrose Agar containing Chloramphenicol (SC), and the plates were then incubated at 27-30ºC for 7-14 days.Results: A total of 210 fungal colonies from equipment (162, 77.1%) and air (48,22.9%) were identified. The most predominant isolated genus was Aspergillus (47.5%),followed by Rhizopus (14.2%), Mucor (11.7%), and Cladosporium (9.2%). Aspergillus(39.5%), Cladosporium (16.6%), as well as Penicillium and Sterile hyphae (10.4% each), were the most isolates from the air samples. Moreover, intensive care units (38.5%) and operating rooms (21.9%) had the highest number of isolated fungal colonies. Out of 256 collected samples from equipment and air, 163 (63.7%) were positive for fungal growth.The rate of fungal contamination in instrument and air samples was 128/213 (60.1%) and 35/43 (81.2%), respectively. Among the isolated species of Aspergillus, A. flavus complex (38/96, 39.6%), A. niger complex (31/96, 32.3%), and A. fumigatus complex (15/96, 15.6%) were the commonest species.Conclusion: According to our findings, in addition to air, equipment and instrument should be considered among the significant sources of fungal contamination in the indoor environment of hospitals. Airborne fungi, Hospital, Indoor air, Equipment, Sources of fungal contamination in the indoor environment of hospitals

    Effect of occupational noise-induced sleep disturbance on worker's health

    No full text
    Aims: In addition to the noise, sleep disturbance (SD) as an outcome of the exposure to the wind turbine noises (WTNs) can adversely affect general health. This study aimed to investigate the effect of SD induced from WTNs on general health indicators. Materials and Methods: A total number of fifty tree workers from Manjil wind farm voluntarily participated in this study. Based on the job similarity and vicinity to the sound sources, workers were classified into three occupational groups including repairman, security, and official staff. Individual's health and sleep status were gathered using the 28-item General Health Questionnaire and Epworth Sleepiness Scales, respectively. Noise was measured based on ISO 9612. ANOVA, Chi-square, and linear and multiple regression tests were used for data analysis in the SPSS 20 software environment. Results: The mean values of 8-h equivalent continuous A-weighted sound pressure level (LAeq, 8 h) among whole workers was 71 ± 10 dB (A). The averages of somatic symptom, anxiety insomnia, social dysfunction, depression, and general health among the participants were 5 ± 2.44, 7 ± 2.35, 11 ± 2.65, 2 ± 1.54, 22 ± 6.53, and 7.3 ± 3.1, respectively. According to the results, SD and noise exposure had an adverse health effect on physical symptoms, depression, and overall general health of participants. Moreover, SD and work experience were effective factors on anxiety-insomnia. SD had greatest effect on general health when all variables are controlled, so that general health will increase by 2.42 units for each unit increase of SD. Conclusion: We found that in addition to the sound effect, noise-induced SD also affects worker's health and strengthen sound effects on human well-being
    corecore