3 research outputs found

    Utilizing of Magnetized Water in Enhancing of Volcanic Concrete Characteristics

    No full text
    Volcanic concrete is an eco-friendly concrete type in that it contains coarse and fine aggregates that all extracted from the igneous volcanic rock. However, utilizing of volcanic ash (VA) as partial/full replacement of concrete cement significantly affects the concrete workability, especially at high cement replacement ratios. This has also some adverse effects on concrete strength. Utilizing magnetized water (MW) in concrete as a partial/full replacement of ordinary tap water (TW) has a notable effect on enhancing the fresh and hardened concrete properties. This research aims to study the effect of using MW prepared in a magnetic field of 1.4 Tesla on the workability and hardened properties (compressive, tensile, and flexural strengths) of volcanic concrete. In this study, VA partially replaced volcanic concrete cement with ratios of 5%, 10%, 15%, and 20%. Ten volcanic concrete mixes were prepared in two groups. The first one was prepared with VA (0–20%) and mixed with TW. The other group was prepared with the same VA contents like group one, but mixed with MW. Microstructure imaging for volcanic concrete was also conducted in this study. Results of water tests showed 17% and 15% increase in total dissolved solids (TDS) and pH, respectively, of MW compared with those of TW. In addition, the water magnetization decreased the water surface tension by 7% compared with that of TW. Results of hardened concrete tests showed that the best ratio of VA in volcanic concrete was 5% with and without using magnetized water. The volcanic concrete slump decreased when using TW; however, using MW enhanced the volcanic concrete slump by up to 8%. The compressive strength was improved by 35%, 23%, and 20% at 7 days, 28 days, and 120 days, respectively, with no VA and with the presence of MW. The compressive strength was improved by 11%, 12%, and 11% after 7 days, 28 days, and 120 days, respectively, with using 5% VA and with the presence of MW. Both splitting tensile strength and flexural strength of volcanic concrete with and without VA or MW behaved similar to that of the corresponding compressive strength

    Influence of Mixing-Water Magnetization Method on the Performance of Silica Fume Concrete

    No full text
    The aim of this study is to experimentally investigate the mechanical characteristics of concrete combining silica fume (SF) and magnetized water (MW). A total of nine concrete mixes were prepared and tested for workability, compressive strength, splitting tensile strength, and flexural strength. Ordinary tap water (TW) and MW that was prepared with five proposed different methods were utilized in the concrete mixes. The MW was prepared by passing TW through a permanent magnetic field (having intensities of 1.4 Tesla and/or 1.6 Tesla) for a different number of cycles, namely 100, 150, and 250 cycles. Water characteristics were analyzed after being magnetized using the proposed different methods and compared with the TW characteristics. Non-destructive concrete testing (ultrasonic pulse velocity, and Schmidt hammer) was also conducted to determine the effect of MW on the prediction of concrete compressive strength. Scanning electron microscopy (SEM) analysis and energy dispersive X-ray (EDX) analysis were carried out on the produced mixes. Regardless of the method utilized to prepare the MW, the results revealed a considerable improvement in concrete compressive strength, splitting tensile strength, and flexural strength by up to 80%, 98%, and 22%, respectively, when MW was prepared with 150 cycles. The best water magnetization method found in this study was the passing of water through magnetic fields of 1.6T then 1.4T intensities for 150 cycles. The ultrasonic pulse velocity test resulted in good prediction of the concrete compressive strength with overall error ranged between −12.6% and +5.8%. MW significantly improved the concrete microstructure and produced a denser structure in comparison to the control conventional concrete

    Characteristics of Sustainable Concrete Containing Metakaolin and Magnetized Water

    No full text
    In this study, fourteen sustainable concrete mixes containing metakaolin (MK) as supplementary cement material (SCM) and magnetized water (MW) as concrete mixing water were designed, prepared, tested, analyzed, and compared. The MK was used as a partial replacement of cement weight by 5%, 10%, and 20%, and as an additive to cement by 5%, 10%, and 20% of cement weight. The MW was used to fully replace tap water (TW) in concrete mixes and was prepared using two different magnetic fields of 1.4 tesla (T) and 1.6 T. This experimental research aimed to assess the characteristics of concrete manufactured with MK and MW. The mechanical and durability characteristics of fresh and hardened concrete were measured for the assessment. Microstructural and chemical analyses were carried out on selected materials and concrete mixes. The workability and compressive strength of the materials at 7, 28, and 365 days were measured, in addition to the splitting tensile strength at 28 days and the flexural strength at 28 days. The compressive strength at 365 days was conducted at 18 °C and 100 °C to study the effect of the applied variables on the concrete durability at different elevated temperatures. The microstructural and chemical analyses were conducted using a scanning electron microscope (SEM), energy dispersive X-ray (EDX), and Fourier transform infrared (FTIR) spectroscopy. The results showed that using 10% MK as a cement additive was the best ratio in this study, which enhanced all the measured mechanical characteristics when the TW or MW was used. Using MW instead of TW in MK concrete increased all the mechanical properties measured at 28 days by about 32–35%. The results of the microstructural and chemical analyses supported the compressive strength increase by showing indications of more C-S-H gel production and less CH when using MW in MK concrete. In addition, fewer micro-cracks and pores, and relatively denser concrete, were detected when using MW with 10% MK as a cement additive
    corecore