6 research outputs found
The Hydrogen Burning Turn-off of RS Ophiuchi 2006
We report a coordinated multi-band photometry of the RS Oph 2006 outburst and
highlight the emission line free y-band photometry that shows a mid-plateau
phase at y ~ 10.2 mag from day 40 to day 75 after the discovery followed by a
sharp drop of the final decline. Such mid-plateau phases are observed in other
two recurrent novae, U Sco and CI Aql, and are interpreted as a bright disk
irradiated by the white dwarf. We have calculated theoretical light curves
based on the optically thick wind theory and have reproduced the observed light
curves including the mid-plateau phase and the final sharp decline. This final
decline is identified with the end of steady hydrogen shell-burning, which
turned out the day ~80. This turnoff date is consistent with the end of a
supersoft X-ray phase observed with Swift. Our model suggests a white dwarf
mass of 1.35 \pm 0.01 M_\sun, which indicates that RS Oph is a progenitor of
Type Ia supernovae. We strongly recommend the y-filter observation of novae to
detect both the presence of a disk and the hydrogen burning turn-off.Comment: to appear in ApJL, 4 pages including 4 figure
Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device
Many sensors have to be used simultaneously for multipoint carbon dioxide (CO2) observation. All the sensors should be calibrated in advance, but this is a time-consuming process. To seek a simplified calibration method, we used four commercial CO2 sensor models and characterized their output tendencies against ambient temperature and length of use, in addition to offset characteristics. We used four samples of standard gas with different CO2 concentrations (0, 407, 1,110, and 1,810 ppm). The outputs of K30 and AN100 models showed linear relationships with temperature and length of use. Calibration coefficients for sensor models were determined using the data from three individual sensors of the same model to minimize the relative RMS error. When the correction was applied to the sensors, the accuracy of measurements improved significantly in the case of the K30 and AN100 units. In particular, in the case of K30 the relative RMS error decreased from 24% to 4%. Hence, we have chosen K30 for developing a portable CO2 measurement device (10 × 10 × 15 cm, 900 g). Data of CO2 concentration, measurement time and location, temperature, humidity, and atmospheric pressure can be recorded onto a Secure Digital (SD) memory card. The CO2 concentration in a high-school lecture room was monitored with this device. The CO2 data, when corrected for simultaneously measured temperature, water vapor partial pressure, and atmospheric pressure, showed a good agreement with the data measured by a highly accurate CO2 analyzer, LI-6262. This indicates that acceptable accuracy can be realized using the calibration method developed in this study