99 research outputs found

    Dynamic splinting for knee flexion contracture following total knee arthroplasty: a case report

    Get PDF
    Total Knee Arthroplasty operations are increasing in frequency, and knee flexion contracture is a common pathology, both pre-existing and post-operative. A 61-year-old male presented with knee flexion contracture following a total knee arthroplasty. Physical therapy alone did not fully reduce the contracture and dynamic splinting was then prescribed for daily low-load, prolonged-duration stretch. After 28 physical therapy sessions, the active range of motion improved from -20° to -12° (stiff knee still lacking full extension), and after eight additional weeks with nightly wear of dynamic splint, the patient regained full knee extension, (active extension improved from -12° to 0°)

    Clinical predictors of elective total joint replacement in persons with end-stage knee osteoarthritis

    Get PDF
    Abstract Background Arthritis is a leading cause of disability in the United States. Total knee arthroplasty (TKA) has become the gold standard to manage the pain and disability associated with knee osteoarthritis (OA). Although more than 400 000 primary TKA surgeries are performed each year in the United States, not all individuals with knee OA elect to undergo the procedure. No clear consensus exists on criteria to determine who should undergo TKA. The purpose of this study was to determine which clinical factors will predict the decision to undergo TKA in individuals with end-stage knee OA. Knowledge of these factors will aid in clinical decision making for the timing of TKA. Methods Functional data from one hundred twenty persons with end-stage knee OA were obtained through a database. All of the individuals complained of knee pain during daily activities and had radiographic evidence of OA. Functional and clinical tests, collectively referred to as the Delaware Osteoarthritis Profile, were completed by a physical therapist. This profile consisted of measuring height, weight, quadriceps strength and active knee range of motion, while functional mobility was assessed using the Timed Up and Go (TUG) test and the Stair Climbing Task (SCT). Self-perceived functional ability was measured using the activities of daily living subscale of the Knee Outcome Survey (KOS-ADLS). A logistic regression model was used to identify variables predictive of TKA use. Results Forty subjects (33%) underwent TKA within two years of evaluation. These subjects were significantly older and had significantly slower TUG and SCT times (p 2 = 0.403). Conclusions Younger patients with full knee ROM who have a higher self-perception of function are less likely to undergo TKA. Physicians and clinicians should be aware that potentially modifiable factors, such as knee ROM can be addressed to potentially postpone the need for TKA.</p

    Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Get PDF
    <p>Abstract</p> <p><b>Background</b></p> <p>Patients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.</p> <p><b>Methods</b></p> <p>To determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.</p> <p><b>Results</b></p> <p>In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.</p> <p><b>Conclusions</b></p> <p>Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.</p

    Muscle strength, gait, and balance in 20 patients with hip osteoarthritis followed for 2 years after THA

    Get PDF
    Background Patients with hip osteoarthritis (OA) have muscular weakness, impaired balance, and limp. Deficits in the different limb muscles and their recovery courses are largely unknown, however. We hypothesized that there is persisting muscular weakness in lower limb muscles and an impaired balance and gait 2 years after THA

    Assessing function in patients undergoing joint replacement: a study protocol for a cohort study

    Get PDF
    BACKGROUND: Joint replacement is an effective intervention for people with advanced arthritis, although there is an important minority of patients who do not improve post-operatively. There is a need for robust evidence on outcomes after surgery, but there are a number of measures that assess function after joint replacement, many of which lack any clear theoretical basis. The World Health Organisation has introduced the International Classification of Functioning, Disability and Health (ICF), which divides function into three separate domains: Impairment, activity limitations and participation restrictions. The aim of this study is to compare the properties and responsiveness of a selection of commonly used outcome tools that assess function, examine how well they relate to the ICF concepts, and to explore the changes in the measures over time. METHODS/DESIGN: Two hundred and sixty three patients listed for lower limb joint replacement at an elective orthopaedic centre have been recruited into this study. Participants attend the hospital for a research appointment prior to surgery and then at 3-months and 1-year after surgery. At each assessment time, function is assessed using a range of measures. Self-report function is assessed using the WOMAC, Aberdeen Impairment, Activity Limitation and Participation Restriction Measure, SF-12 and Measure Yourself Medical Outcome Profile 2. Clinician-administered measures of function include the American Knee Society Score for knee patients and the Harris Hip Score for hip patients. Performance tests include the timed 20-metre walk, timed get up and go, sit-to-stand-to-sit, step tests and single stance balance test. During the performance tests, participants wear an inertial sensor and data from motion analysis are collected. Statistical analysis will include exploring the relationship between measures describing the same ICF concepts, assessing responsiveness, and studying changes in measures over time. DISCUSSION: There are a range of tools that can be used to assess function before and after joint replacement, with little information about how these various measures compare in their properties and responsiveness. This study aims to provide this data on a selection of commonly used assessments of function, and explore how they relate to the ICF domains