12 research outputs found

    Disposition Kinetics of Taxanes in Peritoneal Dissemination

    Get PDF
    Treatment of cancers in the abdominal cavity, such as peritoneal dissemination, is difficult, but in principle intraperitoneal administration of anticancer drugs is expected to be preferable to systemic administration. Taxane anticancer drugs are used to treat gastric cancer patients with peritoneal dissemination. They are administered as micellar preparations, Taxol and Taxotere, which consist of paclitaxel in Cremophor EL (crEL) and docetaxel in Polysorbate-80 (PS-80), respectively. In this paper we review the disposition kinetics of taxane anticancer drugs after intraperitoneal administration in peritoneal dissemination patients and animal models and also discuss the effect of the surfactant vehicle on the behavior of taxanes

    A Triple-Tuned Ultra-Wideband VCO

    No full text

    Artificial intelligence to detect noise events in remote monitoring data

    Get PDF
    Abstract Background Remote monitoring (RM) of cardiac implantable electrical devices (CIEDs) can detect various events early. However, the diagnostic ability of CIEDs has not been sufficient, especially for lead failure. The first notification of lead failure was almost noise events, which were detected as arrhythmia by the CIED. A human must analyze the intracardiac electrogram to accurately detect lead failure. However, the number of arrhythmic events is too large for human analysis. Artificial intelligence (AI) seems to be helpful in the early and accurate detection of lead failure before human analysis. Objective To test whether a neural network can be trained to precisely identify noise events in the intracardiac electrogram of RM data. Methods We analyzed 21 918 RM data consisting of 12 925 and 1884 Medtronic and Boston Scientific data, respectively. Among these, 153 and 52 Medtronic and Boston Scientific data, respectively, were diagnosed as noise events by human analysis. In Medtronic, 306 events, including 153 noise events and randomly selected 153 out of 12 692 nonnoise events, were analyzed in a five‐fold cross‐validation with a convolutional neural network. The Boston Scientific data were analyzed similarly. Results The precision rate, recall rate, F1 score, accuracy rate, and the area under the curve were 85.8 ± 4.0%, 91.6 ± 6.7%, 88.4 ± 2.0%, 88.0 ± 2.0%, and 0.958 ± 0.021 in Medtronic and 88.4 ± 12.8%, 81.0 ± 9.3%, 84.1 ± 8.3%, 84.2 ± 8.3% and 0.928 ± 0.041 in Boston Scientific. Five‐fold cross‐validation with a weighted loss function could increase the recall rate. Conclusions AI can accurately detect noise events. AI analysis may be helpful for detecting lead failure events early and accurately
    corecore