    Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7

    No full text
    A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coated with anti-E. coli O157:H7 antibodies and anti-E. coli O157:H7 antibodies labeled cyanine 5 (Cy5) to make sandwich complexes. Then the Cy5-(E. coli O157:H7)-beads were injected into a flow cell and pulled to the magnetized Ni layer on the optical fiber set in the flow cell. An excitation light (λ = 635 nm) was used to illuminate the optical fiber, and the Cy5 florescent molecules facing the optical fiber were exposed to an evanescent wave from the optical fiber. The 670 nm fluorescent light was measured using a photodiode. Finally, the magnetic intensity of the Ni layer was removed and the Cy5-E. coli O157:H7-beads were washed out for the next immunoassay. E. coli O157:H7, diluted with phosphate buffer (PB), was measured from 1 × 105 to 1 × 107 cells/mL. The total time required for an assay was less than 15 min (except for the pretreatment process) and repeating immunoassay on one optical fiber was made possible

    A Bio-Fluorometric Acetone Gas Imaging System for the Dynamic Analysis of Lipid Metabolism in Human Breath

    No full text
    We constructed an imaging system to measure the concentration of acetone gas by acetone reduction using secondary alcohol dehydrogenase (S-ADH). Reduced nicotinamide adenine dinucleotide (NADH) was used as an electron donor, and acetone was imaged by fluorescence detection of the decrease in the autofluorescence of NADH. In this system, S-ADH–immobilized membranes wetted with buffer solution containing NADH were placed in a dark box, and UV-LED excitation sheets and a high-sensitivity camera were installed on both sides of the optical axis to enable loading of acetone gas. A hydrophilic polytetrafluoroethylene (H-PTFE) membrane with low autofluorescence was used as a substrate, and honeycomb-like through-hole structures were fabricated using a CO2 laser device. After loading the enzyme membrane with acetone gas standards, a decrease in fluorescence intensity was observed in accordance with the concentration of acetone gas. The degree of decrease in fluorescence intensity was calculated using image analysis software; it was possible to quantify acetone gas at concentrations of 50–2000 ppb, a range that includes the exhaled breath concentration of acetone in healthy subjects. We applied this imaging system to measure the acetone gas in the air exhaled by a healthy individual during fasting

    External ears for non-invasive and stable monitoring of volatile organic compounds in human blood

    No full text
    Abstract Volatile organic compounds (VOCs) released through skin (transcutaneous gas) has been increasing in importance for the continuous and real-time assessment of diseases or metabolisms. For stable monitoring of transcutaneous gas, finding a body part with little interference on the measurement is essential. In this study, we have investigated the possibility of external ears for stable and real-time measurement of ethanol vapour by developing a monitoring system that consisted with an over-ear gas collection cell and a biochemical gas sensor (bio-sniffer). The high sensitivity with the broad dynamic range (26 ppb–554 ppm), the high selectivity to ethanol, and the capability of the continuous measurement of the monitoring system uncovered three important characteristics of external ear-derived ethanol with alcohol intake for the first time: there is little interference from sweat glands to a sensor signal at the external ear; similar temporal change in ethanol concentration to that of breath with delayed peak time (avg. 13 min); relatively high concentration of ethanol relative to other parts of a body (external ear-derived ethanol:breath ethanol = 1:590). These features indicated the suitability of external ears for non-invasive monitoring of blood VOCs

    Development of a microconductometric biosniffer for detection of trimethylamine

    No full text
    International audienceThe paper describes the development of a conductometric biosensor for detecting trimethylamine (TMA) which is a good parameter for estimating fish freshness. The biosensor consists of two parts: a microconductometric transducer and a structured enzymatic membrane using a flavin-containing monooxygenase 3 (FMO3) which is known for its sensitivity and selectivity for TMA. The process parameters for the fabrication of the biosniffer and various experimental variables such as pH, time of exposure to glutaraldehyde vapour were investigated with regard to their influence on sensitivity and limit of detection. A low detection limit of 2 mu g/mL (ppm) and a linear range up to 40 mu g/mL (ppm) were obtained. 90% response was reached in less than 10 min. (c) 2007 Elsevier B.V. All rights reserved

    Fiber-Optic Fluoroimmunoassay System with a Flow-Through Cell for Rapid On-Site Determination of Escherichia coli O157:H7 by Monitoring Fluorescence Dynamics

    No full text
    Dynamic fluoroimmunoassay with a flow-through system using optical fiber probes consisting of polystyrene was developed and applied to a quantitative detection of E. coli O157:H7. The system measures E. coli as fluorescence of sandwich-type immune complexes formed by capture antibodies immobilized on the surface of the probe, E. coli cells, and fluorescently labeled detection antibodies. Excitation was carried out using an evanescent wave from the probe. Resulting fluorescence recoupled into the probe was detected by a photodiode. The assay system was constructed with a flow cell which was available for sequential injection of experimental reagents. In vitro characterization was performed using the flow cell, and the calibration range of E. coli O157:H7 was from 103 to 107 cells/mL. The measurement for each sample was completed within 12 min. Furthermore, it was also possible to estimate the concentrations of E. coli O157:H7 by the increasing rate of fluorescence during binding reaction of detection antibodies to antigens. This minimized the time for measurement down to 6 min. The system is suitable for rapid and direct determination for microorganisms or bacteria in food, clinical, and environmental sources

    Biochemical Methanol Gas Sensor (MeOH Bio-Sniffer) for Non-Invasive Assessment of Intestinal Flora from Breath Methanol

    No full text
    Methanol (MeOH) in exhaled breath has potential for non-invasive assessment of intestinal flora. In this study, we have developed a biochemical gas sensor (bio-sniffer) for MeOH in the gas phase using fluorometry and a cascade reaction with two enzymes, alcohol oxidase (AOD) and formaldehyde dehydrogenase (FALDH). In the cascade reaction, oxidation of MeOH was initially catalyzed by AOD to produce formaldehyde, and then this formaldehyde was successively oxidized via FALDH catalysis together with reduction of oxidized form of β-nicotinamide adenine dinucleotide (NAD+). As a result of the cascade reaction, reduced form of NAD (NADH) was produced, and MeOH vapor was measured by detecting autofluorescence of NADH. In the development of the MeOH bio-sniffer, three conditions were optimized: selecting a suitable FALDH for better discrimination of MeOH from ethanol in the cascade reaction; buffer pH that maximizes the cascade reaction; and materials and methods to prevent leaking of NAD+ solution from an AOD-FALDH membrane. The dynamic range of the constructed MeOH bio-sniffer was 0.32–20 ppm, which encompassed the MeOH concentration in exhaled breath of healthy people. The measurement of exhaled breath of a healthy subject showed a similar sensorgram to the standard MeOH vapor. These results suggest that the MeOH bio-sniffer exploiting the cascade reaction will become a powerful tool for the non-invasive intestinal flora testing