4,247 research outputs found

    Development of Uniform CdTe Pixel Detectors Based on Caltech ASIC

    Get PDF
    We have developed a large CdTe pixel detector with dimensions of 23.7 x 13.0 mm and a pixel size of 448 x 448 um^2. The detector is based on recent technologies of an uniform CdTe single crystal, a two-dimensional ASIC, and stud bump-bonding to connect pixel electrodes on the CdTe surface to the ASIC. Good spectra are obtained from 1051 pixels out of total 1056 pixels. When we operate the detector at -50 C, the energy resolution is 0.67 keV and 0.99 keV at 14 keV and 60 keV, respectively. Week-long stability of the detector is confirmed at operating temperatures of both -50 C and -20 C. The detector also shows high uniformity: the peak positions for all pixels agree to within 0.82%, and the average of the energy resolution is 1.04 keV at a temperature of -50 C. When we normalized the peak area by the total counts detected by each pixel, a variation of 2.1 % is obtained.Comment: 11pages, 17figures, accepted for publication in Proc. SPIE 200

    Large amplitude microwave emission and reduced nonlinear phase noise in Co2Fe(Ge0.5Ga0.5) Heusler alloy based pseudo spin valve nanopillars

    Full text link
    We have studied microwave emission from a current-perpendicular-to-plane pseudo spin valve nanopillars with Heusler alloy Co2Fe(Ga0.5Ge0.5) electrodes. Large emission amplitude exceeding 150 nV/Hz^0.5, partly owing to the large magnetoresistance, and narrow generation linewidth below 10 MHz are observed. We also find that the linewidth shows significant dependence on the applied field magnitude and its angle within the film plane. A minimum in the linewidth is observed when the slope of the frequency versus current becomes near zero. This agrees with theoretical prediction that takes into account non-linear phase noise as a source for linewidth broadening

    Water recycling system using thermopervaporation method

    Get PDF
    A water recycling system concept for the crew of the space station is presented. A thermopervaporation method is a new key technology used for the distillation process, utilizing a hydrophobic membrane. An experimental study of thermopervaporation revealed that the permeation depends on the gap between the membrane and the cooling surface in the condensation room: the steam diffusion occurs with gaps less than 5 mm while natural convection becomes dominant with gaps more than 5 mm. A brief discussion of the system operation is also described

    Descending aortic calcification increases renal dysfunction and in-hospital mortality in cardiac surgery patients with intraaortic balloon pump counterpulsation placed perioperatively : a case control study

    Get PDF
    Introduction: Acute kidney injury (AKI) after cardiac surgery increases length of hospital stay and in-hospital mortality. A significant number of patients undergoing cardiac surgical procedures require perioperative intra-aortic balloon pump (IABP) support. Use of an IABP has been linked to an increased incidence of perioperative renal dysfunction and death. This might be due to dislodgement of atherosclerotic material in the descending thoracic aorta (DTA). Therefore, we retrospectively studied the correlation between DTA atheroma, AKI and in-hospital mortality. Methods: A total of 454 patients were retrospectively matched to one of four groups: -IABP/-DTA atheroma, +IABP/-DTA atheroma, -IABP/+DTA atheroma, +IABP/+DTA atheroma. Patients were then matched according to presence/absence of DTA atheroma, presence/absence of IABP, performed surgical procedure, age, gender and left ventricular ejection fraction (LVEF). DTA atheroma was assessed through standard transesophageal echocardiography (TEE) imaging studies of the descending thoracic aorta. Results: Basic patient characteristics, except for age and gender, did not differ between groups. Perioperative AKI in patients with -DTA atheroma/+IABP was 5.1% versus 1.7% in patients with -DTA atheroma/-IABP. In patients with +DTA atheroma/+IABP the incidence of AKI was 12.6% versus 5.1% in patients with +DTA atheroma/-IABP. In-hospital mortality in patients with +DTA atheroma/-IABP was 3.4% versus 8.4% with +DTA atheroma/+IABP. In patients with +DTA atheroma/+IABP in hospital mortality was 20.2% versus 6.4% with +DTA atheroma/-IABP. Multivariate logistic regression identified DTA atheroma > 1 mm (P = *0.002, odds ratio (OR) = 4.13, confidence interval (CI) = 1.66 to 10.30), as well as IABP support (P = *0.015, OR = 3.04, CI = 1.24 to 7.45) as independent predictors of perioperative AKI and increased in-hospital mortality. DTA atheroma in conjunction with IABP significantly increased the risk of developing acute kidney injury (P = 0.0016) and in-hospital mortality (P = 0.0001) when compared to control subjects without IABP and without DTA atheroma. Conclusions: Perioperative IABP and DTA atheroma are independent predictors of perioperative AKI and in-hospital mortality. Whether adding an IABP in patients with severe DTA calcification increases their risk of developing AKI and mortality postoperatively cannot be clearly answered in this study. Nevertheless, when IABP and DTA are combined, patients are more likely to develop AKI and to die postoperatively in comparison to patients without IABP and DTA atheroma

    Direction Finding Estimators of Cyclostationary Signals in Array Processing for Microwave Power Transmission

    Get PDF
    A solar power satellite is paid attention to as a clean, inexhaustible large- scale base-load power supply. The following technology related to beam control is used: A pilot signal is sent from the power receiving site and after direction of arrival estimation the beam is directed back to the earth by same direction. A novel direction-finding algorithm based on linear prediction technique for exploiting cyclostationary statistical information (spatial and temporal) is explored. Many modulated communication signals exhibit a cyclostationarity (or periodic correlation) property, corresponding to the underlying periodicity arising from carrier frequencies or baud rates. The problem was solved by using both cyclic second-order statistics and cyclic higher-order statistics. By evaluating the corresponding cyclic statistics of the received data at certain cycle frequencies, we can extract the cyclic correlations of only signals with the same cycle frequency and null out the cyclic correlations of stationary additive noise and all other co-channel interferences with different cycle frequencies. Thus, the signal detection capability can be significantly improved. The proposed algorithms employ cyclic higher-order statistics of the array output and suppress additive Gaussian noise of unknown spectral content, even when the noise shares common cycle frequencies with the non-Gaussian signals of interest. The proposed method completely exploits temporal information (multiple lag ), and also can correctly estimate direction of arrival of desired signals by suppressing undesired signals. Our approach was generalized over direction of arrival estimation of cyclostationary coherent signals. In this paper, we propose a new approach for exploiting cyclostationarity that seems to be more advanced in comparison with the other existing direction finding algorithms
    • …
    corecore