301 research outputs found

    Adrenal responsiveness to a low-dose ACTH challenge in early and late lactating dairy cows.

    Get PDF
    To improve the evaluation of the chronic stress conditions, the adrenal responsiveness to low dose ACTH stimulation, in different lactation stages, was checked in 56 multiparous dairy cows from 2 herds (25-350 days in milk). Cows were retrospectively ranked in 3 stages: early (150 DIM) lactation. Herd B (vs. herd A) showed higher basal cortisol and frequency of inflammation. Early stage (vs. others) showed higher basal cortisol, bilirubin, ceruloplasmin and haptoglobin, as well as lower ones of cholesterol and lower rise of plasma cortisol during ACTH challenge (P<0.001). Cortisol peak was also correlated negatively with ceruloplasmin, bilirubin, ROM, and positively with cholesterol, vitamin A and E. Both, basal cortisol and cortisol response to ACTH, are associated to inflammation but in opposite way: basal cortisol positively and cortisol response negatively. This latter results are likely due to lower transcortin synthesis, that could be ensued in early lactating cows suffering inflammation

    Change of digesta passage rate in dairy cows after different acute stress situations

    Get PDF
    Six dairy cows received 3 treatments after morning meal, in a double Latin square design. Treatments were ACTH challenge (SYN), hoof trimming (TRIM) and saline (CTR). Measurements included: plasma cortisol and metabolic profile during the 24 h after treatments; the rate of digesta passage, faecal dry matter and pH. Both acute stress situations vs CTR caused a rapid and similar rise in plasma cortisol (P<0.001), while plasma glucose increased only in response to TRIM. Plasma concentrations of urea and BHB were increased for several hours after both stress situations. Most importantly, the transit time of digesta was reduced with SYN and TRIM (P<0.05). Our data demonstrate a reduced forestomach motility during acute stress and confirm a possible negative linkage between stress and gut functions, perhaps independent of diet composition. The mechanism seems linked to increased ACTH or cortisol rather than corticotrophin-releasing factor

    Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode

    Get PDF
    In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge collecting anode of a GEM amplifying structure, has been developed and built. Each charge collecting pad, hexagonally shaped, realized using the top metal layer of a deep submicron VLSI technology is individually connected to a full electronics chain (pre-amplifier, shaping-amplifier, sample and hold, multiplexer) which is built immediately below it by using the remaining five active layers. The GEM and the drift electrode window are assembled directly over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern Gas Detector. With this approach, for the first time, gas detectors have reached the level of integration and resolution typical of solid state pixel detectors. Results from the first tests of this new read-out concept are presented. An Astronomical X-Ray Polarimetry application is also discussed.Comment: 11 pages, 14 figures, presented at the Xth Vienna Conference on Instrumentation (Vienna, February 16-21 2004). For a higher resolution paper contact [email protected]

    Dietary supplementation of garlic and rosemary: effects on colour stability and lipid oxidation in lamb meat

    Get PDF
    The colour of fresh meat is an important criterion consumers take into consideration when purchasing meat. Meat colour depends on the occurrence of chemical and microbial deterioration processes. The role of vitamin E and other antioxidants on ruminant meat colour stability and prevention of lipid oxidation has been widely investigated (Macit et al., 2003; Realini et al., 2004). Many natural herbs and plant extracts exert antioxidant effects such as garlic (Yin and Cheng, 2003) and rosemary (Sánchez-Escalante et al., 2001). Their use as additives for animal feeding may be a valid alternative to synthetic antioxidants since they show beneficial effects also on animal welfare and other physiological functions (Tedesco, 2001). The aim of this study was to evaluate whether garlic and rosemary dietary supplementation as compared with vitamin E affects lamb meat colour and lipid stability during storage

    Single-shot X-ray phase-contrast computed tomography with non-microfocal laboratory sources

    Get PDF
    We present a method that enables performing x-ray phase-contrast imaging (XPCI) computed tomography with a laboratory setup using a single image per projection angle, eliminating the need to move optical elements during acquisition. Theoretical derivation of the method is presented, and its validity conditions are provided. The object is assumed to be quasihomogeneous, i.e., to feature a ratio between the refractive index and the linear attenuation coefficient that is approximately constant across the field of view. The method is experimentally demonstrated on a plastics phantom and on biological samples using a continuous rotation acquisition scheme achieving scan times of a few minutes. Moreover, we show that such acquisition times can be further reduced with the use of a high-efficiency photon-counting detector. Thanks to its ability to substantially simplify the image-acquisition procedure and greatly reduce collection times, we believe this method represents a very important step towards the application of XPCI to real-world problems

    Energy characterization of Pixirad-1 photon counting detector system

    Get PDF
    This work is focused on the characterization of the Pixirad-1 detector system from the spectroscopic point of view. An energy calibration has been carried out using different X-ray sources such as fluorescence lines, synchrotron radiation and radioactive elements. The energy resolution has been measured as function of the energy and the results have been compared with theoretical estimation. Last, the charge sharing fraction has been evaluated by exploiting the monochromatic energy of the Elettra synchrotron beam

    Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether

    Full text link
    The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME) at 0.79 atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45 degrees. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME.Comment: 20 pages, 11 figures, 5 tables. Accepted for publication by NIM

    Assembly and test of the gas pixel detector for X-ray polarimetry

    Get PDF
    The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design, assembly, and preliminary test results of a small GPD for the purpose of gas mixture optimization needed for the phase A study of XIPE. The detector is assembled in house at Tsinghua University following a design by the INFN-Pisa group. The improved detector design results in a good uniformity for the electric field. Filled with pure dimethyl ether (DME) at 0.8 atm, the measured energy resolution is 18% at 6 keV and inversely scales with the square root of the X-ray energy. The measured modulation factor is well consistent with that from simulation, up to ~0.6 above 6 keV. The residual modulation is found to be 0.30±0.15% at 6 keV for the whole sensitive area, which can be translated into a systematic error of less than 1% for polarization measurement at a confidence level of 99%. The position resolution of the detector is about 80 μm in FWHM, consistent with previous studies and sufficient for XIPE requirements

    Low energy polarization sensitivity of the Gas Pixel Detector

    Full text link
    An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances. In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly 45 degrees. The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.Comment: 15 pages, 12 figures. Accepted for publication in NIM
    • …
    corecore