1,202 research outputs found

    A Logical Model and Data Placement Strategies for MEMS Storage Devices

    Full text link
    MEMS storage devices are new non-volatile secondary storages that have outstanding advantages over magnetic disks. MEMS storage devices, however, are much different from magnetic disks in the structure and access characteristics. They have thousands of heads called probe tips and provide the following two major access facilities: (1) flexibility: freely selecting a set of probe tips for accessing data, (2) parallelism: simultaneously reading and writing data with the set of probe tips selected. Due to these characteristics, it is nontrivial to find data placements that fully utilize the capability of MEMS storage devices. In this paper, we propose a simple logical model called the Region-Sector (RS) model that abstracts major characteristics affecting data retrieval performance, such as flexibility and parallelism, from the physical MEMS storage model. We also suggest heuristic data placement strategies based on the RS model and derive new data placements for relational data and two-dimensional spatial data by using those strategies. Experimental results show that the proposed data placements improve the data retrieval performance by up to 4.0 times for relational data and by up to 4.8 times for two-dimensional spatial data of approximately 320 Mbytes compared with those of existing data placements. Further, these improvements are expected to be more marked as the database size grows.Comment: 37 page

    Development of a hybrid magnetic resonance/computed tomography-compatible phantom for magnetic resonance guided radiotherapy

    Get PDF
    The purpose of the present study was to develop a hybrid magnetic resonance/computed tomography (MR/CT)-compatible phantom and tissue-equivalent materials for each MR and CT image. Therefore, the essential requirements necessary for the development of a hybrid MR/CT-compatible phantom were determined and the development process is described. A total of 12 different tissue-equivalent materials for each MR and CT image were developed from chemical components. The uniformity of each sample was calculated. The developed phantom was designed to use 14 plugs that contained various tissue-equivalent materials. Measurement using the developed phantom was performed using a 3.0-T scanner with 32 channels and a Somatom Sensation 64. The maximum percentage difference of the signal intensity (SI) value on MR images after adding K2CO3 was 3.31%. Additionally, the uniformity of each tissue was evaluated by calculating the percent image uniformity (%PIU) of the MR image, which was 82.18 ±1.87% with 83% acceptance, and the average circular-shaped regions of interest (ROIs) on CT images for all samples were within ±5 Hounsfield units (HU). Also, dosimetric evaluation was performed. The percentage differences of each tissue-equivalent sample for average dose ranged from -0.76 to 0.21%. A hybrid MR/CT-compatible phantom for MR and CT was investigated as the first trial in this field of radiation oncology and medical physics

    Does Tumor Size Influence the Diagnostic Accuracy of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules?

    Get PDF
    Background. Fine-needle aspiration cytology (FNAC) is diagnostic standard for thyroid nodules. However, the influence of size on FNAC accuracy remains unclear especially in too small or too large thyroid nodules. The objective of this retrospective cohort study was to investigate the effect of nodule size on FNAC accuracy. Methods. All consecutive patients who underwent thyroidectomy for nodules in 2010 were enrolled. FNAC results (according to the Bethesda system) were compared to pathological diagnosis. The nodules were categorized into groups A–E on the basis of maximal diameter on ultrasound (≤0.5, >0.5–1, >1-2, >2–4, and >4 cm, resp.). Results. There were 502 cases with 690 nodules. Overall FNAC sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.4%, 98.2%, 99.4%, 86.4%, and 96.0%, respectively. False-negative rates (FNRs) of groups A–E were 3.2%, 5.1%, 1.3%, 13.3%, and 50%, respectively. Accuracy rates of groups A–E were 96.8%, 94.8%, 99%, 94.7%, and 87.5%, respectively. Conclusion. Although accuracy rates of FNAC in thyroid nodules smaller than 0.5 cm are comparable to the other group, thyroid nodules larger than 4 cm with benign cytology carry a higher risk of malignancy, which suggest that those should be considered for intensive follow-up or repeated biopsy

    The appropriateness of single page of activation of the cardiac catheterization laboratory by emergency physician for patients with suspected ST-segment elevation myocardial infarction: a cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The early use of reperfusion therapy has a significant effect on the prognosis of patients with ST-segment elevation myocardial infarction (STEMI), and it is recommended that emergency department (ED) physicians activate the cardiac catheterization laboratory (CCL) as soon as possible to treat these patients. The aim of this study was to examine the appropriateness of emergency physician activation of the CCL for patients with suspected STEMI. Inappropriate activations (i.e., false positive activations) were identified according to a variety of criteria.</p> <p>Methods</p> <p>All patients with emergency physician CCL activations between August 2009 and April 2011 were included in the study. False positive cases were defined according to ECG criteria and cardiologists' reviews of patients' initial clinical information.</p> <p>Results</p> <p>ED physicians used a STEMI page to activate the CCL 117 times. According to reviews by cardiologists, this activation was appropriate 89.8% of the time (in 105/117 cases). Truly unnecessary activation (i.e., cases in which STEMI was not identified by the cardiologists, no clear culprit coronary artery was present, no significant coronary artery disease and cardiac biomarkers were negative) occurred 5.1% of the time (in 6/117 cases).</p> <p>Conclusions</p> <p>CCL activation was appropriate for most patients and was unnecessary in a relatively small percentage of cases. This result supports the current recommendation for CCL activation by emergency physicians. Such early activation is a key strategy in the reduction of door-to-balloon time.</p

    The validity of the canadian triage and acuity scale in predicting resource utilization and the need for immediate life-saving interventions in elderly emergency department patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We evaluated the validity of the Canadian Triage and Acuity Scale (CTAS) in elderly emergency department (ED) patients. In particular, we examined the sensitivity and specificity of the CTAS for identifying elderly patients who received an immediate life-saving intervention in the ED.</p> <p>Methods</p> <p>We reviewed the medical records of consecutive patients who were 65 years of age or older and presented to a single academic ED within a three-month period. The CTAS triage scores were compared to actual patient course, including disposition, discharge outcome and resource utilization. We calculated the sensitivity and specificity of the CTAS triage for identifying patients who received an immediate intervention.</p> <p>Results</p> <p>Of the 1903 consecutive patients who were ≥ 65 years of age, 113 (5.9%) had a CTAS level of 1, 174 (9.1%) had a CTAS level of 2, 1154 (60.6%) had a CTAS level of 3, 347 (18.2%) had a CTAS level of 4, and 115 (6.0%) had a CTAS level of 5. As a patient's triage score increased, the severity (such as mortality and intensive care unit admission) and resource utilization increased significantly. Ninety-four of the patients received a life-saving intervention within an hour following their arrival to the ED. The CTAS scores for these patients were 1, 2 and 3 for 46, 46 and 2 patients, respectively. The sensitivity and specificity of a CTAS score of ≤ 2 for identifying patients for receiving an immediate intervention were 97.9% and 89.2%, respectively.</p> <p>Conclusions</p> <p>The CTAS is a triage tool with high validity for elderly patients, and it is an especially useful tool for categorizing severity and for recognizing elderly patients who require immediate life-saving intervention.</p

    Simultaneous Total Occlusion of Multiple Distal Coronary Arteries in Acute Myocardial Infarction

    Get PDF
    Simultaneous multiple coronary artery thrombosis is a rare finding in ST segment elevation myocardial infarction (STEMI). We report a case of myocardial infarction with multiple ST segment elevation on the electrocardiography and total occlusions of the distal left anterior descending artery (dLAD), as well as of the second and third obtuse marginal artery on emergency coronary angiography. Thrombus aspiration was performed at dLAD and systemic glycoprotein IIb/IIIa inhibitor was used successfully. In patients with STEMI, multiple coronary thromboses are unusual and associated with patient fatality. However, assertive thrombus aspiration and antiplatelet therapy could be effective in STEMI patients with multiple distal coronary artery occlusions

    Protective Effect of Yang Mi Ryung® Extract on Noise-Induced Hearing Loss in Mice

    Get PDF
    Noise-induced hearing loss (NIHL) results from the damage of the delicate hair cells inside the ear after excessive stimulation of noise. Unlike certain lower animals such as amphibians, fishes, and birds, in humans, hair cells cannot be regenerated once they are killed or damaged; thus, there are no therapeutic options to cure NIHL. Therefore, it is more important to protect hair cells from the noise before the damage occurs. In this study, we report the protective effect of Yang Mi Ryung extract (YMRE) against NIHL; this novel therapeutic property of YMRE has not been reported previously. Our data demonstrates that the hearing ability damaged by noise is markedly restored in mice preadministrated with YMRE before noise exposure, to the level of normal control group. Our study also provides the molecular mechanism underlying the protective effect of YMRE against NIHL by showing that YMRE significantly blocks noise-induced apoptotic cell death and reduces reactive oxygen species (ROS) production in cochleae. Moreover, quantitative polymerase chain reaction (qPCR) analysis demonstrates that YMRE has anti-inflammatory properties, suppressing the mRNA levels of TNFα and IL-1β induced by noise exposure. In conclusion, YMRE could be a useful preventive intervention to prevent hearing impairment induced by the exposure to excessive noise
    • …
    corecore