3 research outputs found

    Experimental Study on the Flexural Behavior of Reinforced Polystyrene Blocks in Concrete Beams

    Get PDF
    A new type of lightweight beam system was recently proposed by embedding polystyrene in beams to improve structural efficiency. This removes the non-performing concrete in the neutral axis and tension region to provide a comparable strength as a solid beam. There are, however, limited studies conducted to investigate the structural behavior of such beams. Therefore, this research presents an experimental investigation to assess the effect of polystyrene shapes in the beams. This involved testing a solid beam and five lightweight beams under flexural load using a four-point load test. The inclusion of polystyrene was estimated to have reduced the self-weight of beams by 8.6% to 11.8% when compared with the solid beam. The results also showed the ellipse polystyrene with a width of 70 mm and height of 50 mm produced the highest effective strength to weight ratio (sw) of 1.12 and performed 12% better than the solid beam. Moreover, the lightweight beams have more weight reduced than the strength, and those with ellipse polystyrene were found to have performed better than circular ones based on first crack load, ultimate load, and effective strength to weight ratio (sw). The beams with ellipse polystyrene allowed better stress distribution and this gave them a higher strength than sphere shape. For industry application, the polystyrene content is recommended to be greater than 10% while the effective strength to weight ratio (sw) of the beam is greater than 1. The successful reduction of the weight without affecting the structural performance has the ability to help in reducing construction costs

    Palm Oil Fuel Ash (POFA) and Eggshell Powder (ESP) as Partial Replacement for Cement in Concrete

    No full text
    This study is an attempt to partially replace Ordinary Portland cement (OPC) in concrete with palm oil fuel ash (POFA) and eggshell powder (ESP). The mix proportions of POFA and ESP were varied at 10% of cement replacement and compared with OPC concrete as control specimen. The fineness of POFA is characterized by passing through 300 μm sieve and ESP by passing through 75 μm sieve. Compressive strength testing was conducted on concrete specimens to determine the optimum mix proportion of POFA and ESP. Generally the compressive strength of OPC concrete is higher compared to POFA-ESP concrete. Based on the results of POFA-ESP concrete overall, it shows that the optimum mix proportion of concrete is 6%POFA:4% ESP achieved compressive strength of 38.60 N/mm2 at 28 days. The compressive strength of OPC concrete for the same period was 42.37 N/mm2. Higher water demand in concrete is needed due to low fineness of POFA that contributing to low compressive strength of POFA-ESP concrete. However, the compressive strength and workability of the POFA-ESP concrete were within the ranges typically encountered in regular concrete mixtures indicating the viability of this replacement procedure for structural and non-structural applications

    Palm Oil Fuel Ash (POFA) and Eggshell Powder (ESP) as Partial Replacement for Cement in Concrete

    No full text
    This study is an attempt to partially replace Ordinary Portland cement (OPC) in concrete with palm oil fuel ash (POFA) and eggshell powder (ESP). The mix proportions of POFA and ESP were varied at 10% of cement replacement and compared with OPC concrete as control specimen. The fineness of POFA is characterized by passing through 300 μm sieve and ESP by passing through 75 μm sieve. Compressive strength testing was conducted on concrete specimens to determine the optimum mix proportion of POFA and ESP. Generally the compressive strength of OPC concrete is higher compared to POFA-ESP concrete. Based on the results of POFA-ESP concrete overall, it shows that the optimum mix proportion of concrete is 6%POFA:4% ESP achieved compressive strength of 38.60 N/mm2 at 28 days. The compressive strength of OPC concrete for the same period was 42.37 N/mm2. Higher water demand in concrete is needed due to low fineness of POFA that contributing to low compressive strength of POFA-ESP concrete. However, the compressive strength and workability of the POFA-ESP concrete were within the ranges typically encountered in regular concrete mixtures indicating the viability of this replacement procedure for structural and non-structural applications
    corecore