16 research outputs found

    Coherent Control of the Exciton Dynamics in the FMO Protein

    Get PDF
    We have achieved first steps toward coherent control of excitonic energy migration in the FMO pigment-protein complex, by combining femtosecond pulse shaping with a feedback loop using an evolutionary algorithm. The experimental conditions achieved, with a rotating sample, a cryostat, and a pulse shaper, are sufficient for closed loop optimizations.</p

    Commissioning and clinical implementation of the first commercial independent Monte Carlo 3D dose calculation to replace CyberKnife M6â„¢ patient-specific QA measurements

    Get PDF
    Purpose: To report on the commissioning and clinical validation of the first commercially available independent Monte Carlo (MC) three-dimensional (3D) dose calculation for CyberKnife robotic radiosurgery system® (Accuray, Sunnyvale, CA). Methods: The independent dose calculation (IDC) by SciMoCa® (Scientific RT, Munich, Germany) was validated based on water measurements of output factors and dose profiles (unshielded diode, field-size dependent corrections). A set of 84 patient-specific quality assurance (QA) measurements for multi-leaf collimator (MLC) plans, using an Octavius two-dimensional SRS1000 array (PTW, Freiburg, Germany), was compared to results of respective calculations. Statistical process control (SPC) was used to detect plans outside action levels. Results: Of all output factors for the three collimator systems of the CyberKnife, 99% agreed within 2% and 81% within 1%, with a maximum deviation of 3.2% for a 5-mm fixed cone. The profiles were compared using a one-dimensional gamma evaluation with 2% dose difference and 0.5 mm distance-to-agreement (Γ(2,0.5)). The off-centre ratios showed an average pass rate >99% (92–100%). The agreement of the depth dose profiles depended on field size, with lowest pass rates for the smallest MLC field sizes. The average depth dose pass rate was 88% (35–99%). The IDCs showed a Γ(2,1) pass rate of 98%. Statistical process control detected six plans outside tolerance levels in the measurements, all of which could be attributed the measurement setup. Independent dose calculations showed problems in five plans, all due to differences in the algorithm between TPS and IDC. Based on these results changes were made in the class solution for treatment plans. Conclusion: The first commercially available MC 3D dose IDC was successfully commissioned and validated for the CyberKnife and replaced all routine patientspecific QA measurements in our clinic

    Largely reduced OAR doses, and planning and delivery times for challenging robotic SBRT cases, obtained with a novel optimizer

    Get PDF
    Recently, VOLO™ was introduced as a new optimizer for CyberKnife® planning. In this study, we investigated possibilities to improve treatment plans for MLC-based prostate SBRT with enhanced peripheral zone dose while sparing the urethra, and central lung tumors, compared to existing Sequential Optimization (SO). The primary focus was on reducing OAR doses. For 25 prostate and 25 lung patients treated with SO plans, replanning with VOLO™ was performed with the same planning constraints. For equal PTV coverage, almost all OAR plan parameters were improved with VOLO™. For prostate patients, mean rectum and bladder doses were reduced by 34.2% (P < 0.001) and 23.5% (P < 0.001), with reductions in D0.03cc of 3.9%, 11.0% and 3.1% for rectum, mucosa and bladder (all P ≤ 0.01). Urethra D5% and D10% were 3.8% and 3.0% lower (P ≤ 0.002). For lung patients, esophagus, main bronchus, trachea, and spinal cord D0.03cc was reduced by 18.9%, 11.1%, 16.1%, and 13.2%, respectively (all P ≤ 0.01). Apart from the dosimetric advantages of VOLO™ planning, average reductions in MU, numbers of beams and nodes for prostate/lung were 48.7/32.8%, 26.5/7.9% and 13.4/7.9%, respectively (P ≤ 0.003). VOLO™ also resulted in reduced delivery times with mean/max reductions of: 27/43% (prostate) and 15/41% (lung), P < 0.001. Planning times reduced from 6 h to 1.1 h and from 3 h to 1.7 h for prostate and lung, respectively. The new VOLO™ planning was highly superior to SO planning in terms of dosimetric plan quality, and planning and delivery times

    Carrier Multiplication and Its Reduction by Photodoping in Colloidal InAs Quantum Dots: Addition/correction

    No full text
    Carrier (exciton) multiplication in colloidal InAs/CdSe/ZnSe core−shell quantum dots (QDs) is investigated using terahertz time-domain spectroscopy, time-resolved transient absorption, and quasi-continuous wave excitation spectroscopy. For excitation by high-energy photons (2.7 times the band gap energy), highly efficient carrier multiplication (CM) results in the appearance of multi-excitons, amounting to 1.6 excitons per absorbed photon. Multi-exciton recombination occurs within tens of picoseconds via Auger-type processes. Photodoping (i.e., photoinjection of an exciton) of the QDs prior to excitation results in a reduction of the CM efficiency to 1.3. This exciton-induced reduction of CM efficiency can be explained by the twofold degeneracy of the lowest conduction band energy level. We discuss the implications of our findings for the potential application of InAs QDs as light absorbers in solar cells. \u
    corecore