160 research outputs found
Pancreatic cancer
CĂĄncer de pĂĄncreasCĂ ncer de pĂ ncreesPancreatic cancerThe need for a common education and training track in surgical oncology across Europe has been emphasized. ESSO provides several hands-on courses for skills training and face-to-face discussions. The core curriculum provides a framework for the overall theoretical requirements in surgical oncology. The UEMS/EBSQ fellowship exam is designed to test core competencies in the candidate's core knowledge in their prespecified area of expertise. A core set of points for each cancer type is lacking. Hence, a condensed outline of themed expected to be covered in the curriculum and relevant to an optimal practice in surgical oncology is provided. This article outlines pancreatic cancer
Semi-automatic standardized analysis method to objectively evaluate near-infrared fluorescent dyes in image-guided surgery
Significance: Near-infrared fluorescence imaging still lacks a standardized, objective method to evaluate fluorescent dye efficacy in oncological surgical applications. This results in difficulties in translation between preclinical to clinical studies with fluorescent dyes and in the reproduction of results between studies, which in turn hampers further clinical translation of novel fluorescent dyes. Aim: Our aim is to develop and evaluate a semi-automatic standardized method to objectively assess fluorescent signals in resected tissue. Approach: A standardized imaging procedure was designed and quantitative analysis methods were developed to evaluate non-targeted and tumor-targeted fluorescent dyes. The developed analysis methods included manual selection of region of interest (ROI) on white light images, automated fluorescence signal ROI selection, and automatic quantitative image analysis. The proposed analysis method was then compared with a conventional analysis method, where fluorescence signal ROIs were manually selected on fluorescence images. Dice similarity coefficients and intraclass correlation coefficients were calculated to determine the inter- and intraobserver variabilities of the ROI selections and the determined signal- and tumor-to-background ratios. Results: The proposed non-targeted fluorescent dyes analysis method showed statistically significantly improved variabilities after application on indocyanine green specimens. For specimens with the targeted dye SGM-101, the variability of the background ROI selection was statistically significantly improved by implementing the proposed method. Conclusion: Semi-automatic methods for standardized quantitative analysis of fluorescence images were successfully developed and showed promising results to further improve the reproducibility and standardization of clinical studies evaluating fluorescent dyes.</p
Semi-automatic standardized analysis method to objectively evaluate near-infrared fluorescent dyes in image-guided surgery
Significance: Near-infrared fluorescence imaging still lacks a standardized, objective method to evaluate fluorescent dye efficacy in oncological surgical applications. This results in difficulties in translation between preclinical to clinical studies with fluorescent dyes and in the reproduction of results between studies, which in turn hampers further clinical translation of novel fluorescent dyes. Aim: Our aim is to develop and evaluate a semi-automatic standardized method to objectively assess fluorescent signals in resected tissue. Approach: A standardized imaging procedure was designed and quantitative analysis methods were developed to evaluate non-targeted and tumor-targeted fluorescent dyes. The developed analysis methods included manual selection of region of interest (ROI) on white light images, automated fluorescence signal ROI selection, and automatic quantitative image analysis. The proposed analysis method was then compared with a conventional analysis method, where fluorescence signal ROIs were manually selected on fluorescence images. Dice similarity coefficients and intraclass correlation coefficients were calculated to determine the inter- and intraobserver variabilities of the ROI selections and the determined signal- and tumor-to-background ratios. Results: The proposed non-targeted fluorescent dyes analysis method showed statistically significantly improved variabilities after application on indocyanine green specimens. For specimens with the targeted dye SGM-101, the variability of the background ROI selection was statistically significantly improved by implementing the proposed method. Conclusion: Semi-automatic methods for standardized quantitative analysis of fluorescence images were successfully developed and showed promising results to further improve the reproducibility and standardization of clinical studies evaluating fluorescent dyes.</p
External validation of three lymph node ratio-based nomograms predicting survival using an international cohort of patients with resected pancreatic head ductal adenocarcinoma.
INTRODUCTION
Lymph node ratio (LNR) is an important prognostic factor of survival in patients with pancreatic ductal adenocarcinoma (PDAC). This study aimed to validate three LNR-based nomograms using an international cohort.
MATERIALS AND METHODS
Consecutive PDAC patients who underwent upfront pancreatoduodenectomy from six centers (Europe/USA) were collected (2000-2017). Patients with metastases, R2 resection, missing LNR data, and who died within 90 postoperative days were excluded. The updated Amsterdam nomogram, the nomogram by Pu et al., and the nomogram by Li et al. were selected. For the validation, calibration, discrimination capacity, and clinical utility were assessed.
RESULTS
After exclusion of 176 patients, 1'113 patients were included. Median overall survival (OS) of the cohort was 23 months (95% CI: 21-25). For the three nomograms, Kaplan-Meier curves showed significant OS diminution with increasing scores (p < 0.01). All nomograms showed good calibration (non-significant Hosmer-Lemeshow tests). For the Amsterdam nomogram, area under the ROC curve (AUROC) for 3-year OS was 0.64 and 0.67 for 5-year OS. Sensitivity and specificity for 3-year OS prediction were 65% and 59%. Regarding the nomogram by Pu et al., AUROC for 3- and 5-year OS were 0.66 and 0.70. Sensitivity and specificity for 3-year OS prediction were 68% and 53%. For the Li nomogram, AUROC for 3- and 5-year OS were 0.67 and 0.71, while sensitivity and specificity for 3-year OS prediction were 63% and 60%.
CONCLUSION
The three nomograms were validated using an international cohort. Those nomograms can be used in clinical practice to evaluate survival after pancreatoduodenectomy for PDAC
Prolonged antibiotic prophylaxis after pancreatoduodenectomy:systematic review and meta-analysis
Background: Previous studies have reported conflicting results of prolonged antibiotic prophylaxis on infectious complications after pancreatoduodenectomy. This study evaluated the effect of prolonged antibiotics on surgical-site infections (SSIs) after pancreatoduodenectomy. Methods: A systematic review and meta-analysis was undertaken of SSIs in patients with perioperative (within 24 h) versus prolonged antibiotic (over 24 h) prophylaxis after pancreatoduodenectomy. SSIs were classified as organ/space infections or superficial SSI within 30 days after surgery. ORs were calculated using a MantelâHaenszel fixed-effect model.Results:Ten studies were included in the qualitative analysis, of which 8 reporting on 1170 patients were included in the quantitative analysis. The duration of prolonged antibiotic prophylaxis varied between 2 and 10 days after surgery. Four studies reporting on 782 patients showed comparable organ/space infection rates in patients receiving perioperative and prolonged antibiotics (OR 1.35, 95 per cent c.i. 0.94 to 1.93). However, among patients with preoperative biliary drainage (5 studies reporting on 577 patients), organ/space infection rates were lower with prolonged compared with perioperative antibiotics (OR 2.09, 1.43 to 3.07). Three studies (633 patients) demonstrated comparable superficial SSI rates between patients receiving perioperative versus prolonged prophylaxis (OR 1.54, 0.97 to 2.44), as well as in patients with preoperative biliary drainage in 4 studies reporting on 431 patients (OR 1.60, 0.89 to 2.88). Conclusion: Prolonged antibiotic prophylaxis is associated with fewer organ/space infection in patients who undergo preoperative biliary drainage. However, the optimal duration of antibiotic prophylaxis after pancreatoduodenectomy remains to be determined and warrants confirmation in an RCT.</p
Near-Infrared Fluorescence Imaging of Liver Metastases in Rats using Indocyanine Green
BackgroundNear-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is a promising technique to obtain real-time assessment of the extent and number of colorectal liver metastases during surgery. The current study aims to optimize dosage and timing of ICG administration.Materials and MethodsLiver tumors were induced in 18 male WAG/Rij rats by subcapsular inoculation of CC531 rat colorectal cancer cells into three distinct liver lobes. Rats were divided in two groups: imaging after 24 and 48 h or 72 and 96 h after intravenous ICG administration. In each time group, rats were allocated to three dose groups: 0.04, 0.08, or 0.16 mg ICG. Intraoperative imaging and ex vivo measurements were performed using the Mini-FLARE imaging system and confirmed by fluorescence microscopy. Fluorescence intensity was quantified using the Mini-FLARE software and the difference between tumor signal and liver signal (tumor-to-liver ratio; TLR) was calculated.ResultsIn all 18 rats, all colorectal liver metastases (n = 34), some as small as 1.2 mm, were identified using ICG and the Mini-FLARE imaging system. Average tumor-to-liver ratio (TLR) over all groups was 3.0 ± 1.2. TLR was significantly higher in the 72 h time group compared with other time points. ICG dose did not significantly influence TLR, but a trend was found favoring the 0.08 mg dose group. Fluorescence microscopy demonstrated a clear fluorescent rim around the tumor.ConclusionsThis study demonstrates that colorectal cancer liver metastases can be clearly identified during surgery using ICG and the Mini-FLARE imaging system, with optimal timing of 72 h post-injection and an optimal dose of 0.08 mg (0.25 mg/kg) ICG. NIR fluorescence imaging has the potential to improve intraoperative detection of micrometastases and, thus, the completeness of resection
Therapeutic anticoagulation for splanchnic vein thrombosis in acute pancreatitis:A national survey and case-vignette study
BACKGROUND: Splanchnic vein thrombosis (SVT) is a major complication of moderate and severe acute pancreatitis. There is no consensus on whether therapeutic anticoagulation should be started in patients with acute pancreatitis and SVT. AIM: To gain insight into current opinions and clinical decision making of pancreatologists regarding SVT in acute pancreatitis. METHODS: A total of 139 pancreatologists of the Dutch Pancreatitis Study Group and Dutch Pancreatic Cancer Group were approached to complete an online survey and case vignette survey. The threshold to assume group agreement was set at 75%. RESULTS: The response rate was 67% (n = 93). Seventy-one pancreatologists (77%) regularly prescribed therapeutic anticoagulation in case of SVT, and 12 pancreatologists (13%) for narrowing of splanchnic vein lumen. The most common reason to treat SVT was to avoid complications (87%). Acute thrombosis was the most important factor to prescribe therapeutic anticoagulation (90%). Portal vein thrombosis was chosen as the most preferred location to initiate therapeutic anticoagulation (76%) and splenic vein thrombosis as the least preferred location (86%). The preferred initial agent was low molecular weight heparin (LMWH; 87%). In the case vignettes, therapeutic anticoagulation was prescribed for acute portal vein thrombosis, with or without suspected infected necrosis (82% and 90%), and thrombus progression (88%). Agreement was lacking regarding the selection and duration of long-term anticoagulation, the indication for thrombophilia testing and upper endoscopy, and about whether risk of bleeding is a major barrier for therapeutic anticoagulation. CONCLUSION: In this national survey, the pancreatologists seemed to agree on the use of therapeutic anticoagulation, using LMWH in the acute phase, for acute portal thrombosis and in the case of thrombus progression, irrespective of the presence of infected necrosis.</p
Surgical management and pathological assessment of pancreatoduodenectomy with venous resection: an international survey among surgeons and pathologists
Background: The aim of this survey was to gain insights in the current surgical management and pathological assessment of pancreatoduodenectomy with portalâsuperior mesenteric vein resection (VR). Methods: A systematic literature search was performed to identify international expert surgeons (N = 150) and pathologists (N = 40) who published relevant studies between 2009 and 2019. These experts and Dutch surgeons (N = 17) and pathologists (N = 20) were approached to complete an online survey. Results: Overall, 76 (46%) surgeons and 37 (62%) pathologists completed the survey. Most surgeons (71%) estimated that preoperative imaging corresponded correctly with intraoperative findings of venous involvement in 50â75% of patients. An increased complication risk following VR was expected by 55% of surgeons, mainly after Type 4 (segmental resection-venous conduit anastomosis). Most surgeons (61%) preferred Type 3 (segmental resection-primary anastomosis). Most surgeons (75%) always perform the VR themselves. Standard postoperative imaging for patency control was performed by 54% of surgeons and 39% adjusted thromboprophylaxis following VR. Most pathologists (76%) always assessed tumor infiltration in the resected vein and only 54% of pathologists always assess the resection margins of the vein itself. Variation in assessment of tumor infiltration depth was observed. Conclusion: This international survey showed variation in the surgical management and pathological assessment of pancreatoduodenectomy with venous involvement. This highlights the lack of evidence and emphasizes the need for research on imaging modalities to improve patient selection for VR, surgical techniques, postoperative management and standardization of the pathological assessment
- âŠ