7 research outputs found
Technical note: Cryostat transmission characterization for MR linac – temporal stability, clinical impact and change implementation
Background: In the Unity MR linac (Elekta AB, Stockholm, Sweden), the radiation beam traverses the cryostat and the coil support structure. The resulting beam attenuation must be considered for output calibration and its variation with gantry angle must be characterized in the treatment planning system (TPS). Purpose: The aim of this work was to investigate the impact of a change of the cryostat transmission characterization (CTC) curve, due to the helium level modification, on clinical treatment plan dosimetry and to report on the experience with the CTC curve update. Methods: Twenty stereotactic body radiotherapy (SBRT) treatment plans: 10 prostate and 10 oligo-metastatic cancer plans, prepared with a beam model incorporating the CTC curve acquired at installation time, were re-calculated using the model implementing CTC curve post helium top-up. To account for the CTC change as well as to align our system to the recent reference conditions recommendations, the new model was commissioned with the emphasis on the specifics associated with the treatment plan adaptation and the existence of the offline and online TPS components. Results: Average CTV mean dose reduction by 0.45% in prostate cases and average GTV mean dose reduction by 0.22% in oligo-metastatic cases was observed. Updated model validation showcased good agreement between measurements and TPS calculations. Conclusions: The agreement between CTC measurements demonstrates its temporal constancy and robustness of the measurement method employed. A helium fill level change was shown to affect the CTC and led to a small but systematic dose calculation inaccuracy. Finally, model validation and end-to-end testing results presented, underscore the minimal impact of transitioning to the new beam model and new reference conditions
Magnetic resonance guided adaptive post prostatectomy radiotherapy: Accumulated dose comparison of different workflows
Purpose: The aim of this study was to assess the use of magnetic resonance guided adaptive radiotherapy (MRgART) in the post-prostatectomy setting; comparing dose accumulation for our initial seven patients treated with fully adaptive workflow on the Unity MR-Linac (MRL) and with non-adaptive plans generated offline. Additionally, we analyzed toxicity in patients receiving treatment. Methods: Seven patients were treated with MRgART. The prescription was 70–72 Gy in 35–36 fractions. Patients were treated with an adapt to shape (ATS) technique. For each clinically delivered plan, a non-adaptive plan based upon the reference plan was generated and compared to the associated clinically delivered plan. A total of 468 plans were analyzed. Concordance Index of target and Organs at Risk (OARs) for each fraction with reference contours was analyzed. Acute toxicity was then assessed at six-months following completion of treatment with Common Terminology for Adverse Events (CTCAE) Toxicity Criteria. Results: A total of 246 fractions were clinically delivered to seven patients; 234 fractions were delivered via MRgART and 12 fractions delivered via a traditional linear accelerator due to machine issues. Pre-treatment reference plans met CTV and OAR criteria. PTV coverage satisfaction was higher in the clinically delivered adaptive plans than non-adaptive comparison plans; 42.93% versus 7.27% respectively. Six-month CTCAE genitourinary and gastrointestinal toxicity was absent in most patients, and mild-to-moderate in a minority of patients (Grade 1 GU toxicity in one patient and Grade 2 GI toxicity in one patient). Conclusions: Daily MRgART treatment consistently met planning criteria. Target volume variability in prostate bed treatment can be mitigated by using MRgART and deliver satisfactory coverage of CTV whilst minimizing dose to adjacent OARs and reducing toxicity
Old dogs, new tricks: MR‐Linac training and credentialing of radiation oncologists, radiation therapists and medical physicists
Abstract The introduction of magnetic resonance (MR) linear accelerators (MR‐Linacs) into radiotherapy departments has increased in recent years owing to its unique advantages including the ability to deliver online adaptive radiotherapy. However, most radiation oncology professionals are not accustomed to working with MR technology. The integration of an MR‐Linac into routine practice requires many considerations including MR safety, MR image acquisition and optimisation, image interpretation and adaptive radiotherapy strategies. This article provides an overview of training and credentialing requirements for radiation oncology professionals to develop competency and efficiency in delivering treatment safely on an MR‐Linac
Introduction of radiation therapist‐led adaptive treatments on a 1.5 T MR‐Linac
Abstract The introduction of magnetic resonance (MR) linear accelerators (MR‐Linac) marks the beginning of a new era in radiotherapy. MR‐Linac systems are currently being operated by teams of radiation therapists (RTs), radiation oncology medical physicists (ROMPs) and radiation oncologists (ROs) due to the diverse and complex tasks required to deliver treatment. This is resource‐intensive and logistically challenging. RT‐led service delivery at the treatment console is paramount to simplify the process and make the best use of this technology for suitable patients with commonly treated anatomical sites. This article will discuss the experiences of our department in developing and implementing an RT‐led workflow on the 1.5 T MR‐Linac
Radiation-Stimulated Translocation of CD166 and CRYAB to the Endothelial Surface Provides Potential Vascular Targets on Irradiated Brain Arteriovenous Malformations
Vascular targeting with pro-thrombotic antibody-conjugates is a promising biological treatment for brain arteriovenous malformations (bAVMs). However, targeted drug delivery relies on the identification of unique or overexpressed markers on the surface of a target cell. In the absence of inherent biological markers, stereotactic radiosurgery may be used to prime induction of site-specific and targetable molecular changes on the endothelial surface. To investigate lumen-accessible, endothelial targets induced by radiation, we combined Gamma knife surgery in an AVM animal model with in vivo biotin-labeling and comparative proteomics. Two proteins, αB-crystallin (CRYAB)—a small heat shock protein that normally acts as an intracellular chaperone to misfolded proteins—and activated leukocyte cell adhesion molecule CD166, were further validated for endothelial surface expression after irradiation. Immunostaining of endothelial cells in vitro and rat AVM tissue ex vivo confirmed de novo induction of CRYAB following irradiation (20 Gy). Western analysis demonstrated that CRYAB accumulated intracellularly as a 20 kDa monomer, but, at the cell surface, a novel 65 kDa protein was observed, suggesting radiation stimulates translocation of an atypical CRYAB isoform. In contrast, CD166 had relatively high expression in non-irradiated cells, localized predominantly to the lateral surfaces. Radiation increased CD166 surface exposure by inducing translocation from intercellular junctions to the apical surface without significantly altering total protein levels. These findings reinforce the dynamic molecular changes induced by radiation exposure, particularly at the cell surface, and support further investigation of radiation as a priming mechanism and these molecules as putative targets for focused drug delivery in irradiated tissue
Early experience with MR‐guided adaptive radiotherapy using a 1.5 T MR‐Linac: First 6 months of operation using adapt to shape workflow
IntroductionThe magnetic resonance linear accelerator (MRL) offers improved soft tissue visualization to guide daily adaptive radiotherapy treatment. This manuscript aims to report initial experience using a 1.5 T MRL in the first 6 months of operation, including training, workflows, timings and dosimetric accuracy.MethodsAll staff received training in MRI safety and MRL workflows. Initial sites chosen for treatment were stereotactic and hypofractionated prostate, thoraco-abdomino-pelvic metastasis, prostate bed and bladder. The Adapt To Shape (ATS) workflow was chosen to be the focus of treatment as it is the most robust solution for daily adaptive radiotherapy. A workflow was created addressing patient suitability, simulation, planning, treatment and peer review. Treatment times were recorded breaking down into the various stages of treatment.ResultsA total of 37 patients were treated and 317 fractions delivered (of which 313 were delivered using an ATS workflow) in our initial 6 months. Average treatment times over the entire period were 50 and 38 min for stereotactic and non-stereotactic treatments respectively. Average treatment times reduced each month. The average difference between reference planned and ionization chamber measured dose was 0.0 ± 1.4%.ConclusionThe MRL was successfully established in an Australian setting. A focus on training and creating a detailed workflow from patient selection, review and treatment are paramount to establishing new treatment programmes