8 research outputs found

    Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: Pulsed lavage versus syringe lavage

    Full text link
    The aim of the study was to determine whether the incidence of radiolucencies can be reduced using pulsed lavage before cementing the tibia in unicompartmental knee arthroplasty (UKA). We prospectively studied a consecutive series of 112 cemented Oxford UKA in 100 patients in two centres. In group A (n = 56) pulsed lavage and in group B (n = 56) conventional syringe lavage was used to clean the cancellous bone. The same standardised cementing technique was applied in all cases. At a minimum follow-up of one year patients were evaluated clinically and screened radiographs were obtained. The cement bone interface under the tibial plateau was divided into four zones and evaluated for the presence of radiolucent lines. All radiographs were evaluated (n = 112), and radiolucencies in all four zones were found in two cases in group A (4%) and in 12 cases in group B (22%) (p = 0.0149). Cement penetration showed a median of 2.6 mm (group A) and 1.5 mm (group B) (p < 0.0001). We recommend the routine use of pulsed lavage in Oxford UKA to reduce the incidence of radiolucency and to improve long-term fixation

    Pulsed lavage improves fixation strength of cemented tibial components

    Full text link
    Pulsatile lavage is purported to improve radiographic survival in cemented total knee arthroplasty (TKA). Similarly, a potential improvement of fixation strength of the tibial tray has been assumed based on the increased cement penetration. In this study, the influence of pulsed lavage on fixation strength of the tibial component and bone cement penetration was evaluated in six pairs of cadaveric specimens. Following surgical preparation, the tibial surface was irrigated using pulsatile lavage on one side of a pair, while on the other side syringe lavage was applied. All tibial components were implanted using the same cementing technique. Cement penetration and bone mineral density was assessed based on computed tomography data. Fixation strength of the tibial trays was determined by a pull-out test with a material testing machine. Median pull-out forces and cement penetration were significantly (p = 0.031) improved in the pulsed lavage group as compared to the syringe lavage group. Enhanced fixation strength is suggested as being a key to improved survival of the implant. Consequently, pulsatile lavage should be considered as a mandatory preparation step when cementing tibial components in TKA

    The UniSpacer™: correcting varus malalignment in medial gonarthrosis

    Full text link
    While options for operative treatment of leg axis varus malalignment in patients with medial gonarthrosis include several established procedures, such as unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or high tibial osteotomy (HTO), there has been little focus on a less invasive option introduced more recently: the UniSpacer™ implant, a self-centering, metallic interpositional device for the knee. This study evaluates clinical and radiological results of the UniSpacer™, whether alignment correction can be achieved by UniSpacer™ arthroplasty and alignment change in the first five postoperative years. Anteroposterior long leg stance radiographs of 20 legs were digitally analysed to assess alignment change: two relevant angles and the deviation of the mechanical axis of the leg were analysed before and after surgery. Additionally, the change of the postoperative alignment was determined one and five years postoperatively. Analysing the mechanical tibiofemoral angle, a significant leg axis correction was achieved, with a mean valgus change of 4.7 ± 1.9°; a varus change occurred in the first postoperative year, while there was no significant further change of alignment seen five years after surgery. The UniSpacer™ corrects malalignment in patients with medial gonarthrosis; however, a likely postoperative change in alignment due to implant adaptation to the joint must be considered before implantation. Our results show that good clinical and functional results can be achieved after UniSpacer™ arthroplasty. However, four of 19 knees had to be revised to a TKA or UKA due to persistent pain, which is an unacceptably high revision rate when looking at the alternative treatment options of medial osteoarthritis of the knee

    Long-term results of the threaded Mecron cup in primary total hip arthroplasty: A 15–20-year follow-up study

    Full text link
    In the 1970s, high failure rates of cemented acetabular components, especially in young patients, in the middle- and long-term prompted a search for alternatives. The Mecring was one of the most popular first generation uncemented, threaded cups widely used in the 1980s for arthroplasty of the hip. First generation threaded cups commonly had smooth surface treatment and showed unacceptably high failure rates in the mid-term. In a consecutive series of 209 patients, 221 threaded uncemented acetabular cups with smooth surface treatment (Mecring) had been implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. The mean time of follow-up was 17 (range 15–20) years. In 91 (41%) hips the acetabular component had been revised or was awaiting revision: two hips for infection and 84 (38%) for aseptic loosening. Five hips were awaiting revision. The survival rate for all revisions including hips awaiting revision was 49% (95% CI: 41–57%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. Patients with these components must be closely monitored as the failure rate remains high in the long-term

    Correlation of positioning and clinical results in Oxford UKA

    Full text link
    In a prospective clinical study, 59 patients with anteromedial osteoarthritis of the knee (61 knee joints) underwent minimally invasive medial Oxford unicompartmental arthroplasty phase 3. Clinical and radiographic examinations of 56 knees were carried out at five (4–7) years. American Knee Society (AKS) scores improved from mean 45.5 (20–80) points (knee score) and 55 (15–100) points (function score) before surgery to 90 (30–100) points in both scores after surgery. The position of each implant was determined on screened radiographs using an image intensifier. The implant position was analysed according to the Oxford X-ray rating system. We evaluated nine measures, and there was no detectable correlation between implant position and clinical result. However, long-term studies are needed before it is possible to elaborate an evidence-based guideline on positioning

    Long-term results of the threaded Weill cup in primary total hip arthroplasty : A 15–20-year follow-up study

    Full text link
    Uncemented, threaded acetabular components with smooth surface treatment were widely used in continental Europe in the 1970s and 1980s for primary total hip arthroplasty (THA). Previously published studies showed high failure rates in the mid-term. In a consecutive series of 116 patients, 127 threaded cups with smooth surface treatment (Weill cup; Zimmer, Winterthur, Switzerland) were implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. Mean time of follow-up was 17 years (range 15–20). At the time of follow-up, the acetabular component had been revised or was awaiting revision in 30 hips (24%). Two hips were revised for infection and 23 for aseptic loosening. Four polyethylene liners were exchanged because of excessive wear. One hip was awaiting revision. The survival rate for all acetabular revisions including one hip awaiting revision was 75% (95%CI: 65–85%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. It is important to closely monitor patients with these components as the failure rate remains high in the long-term
    corecore